Short-term Outcomes With Small Intestinal Submucosa for Ventral Abdominal Hernia
The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
HYPOTHESIS: A bioabsorbable tissue scaffold of porcine submucosal small intestine extracellular matrix (Surgisis Gold [SIS]; Cook Biotech Inc, West Lafayette, Ind) mesh is safe and effective for ventral hernia repair. DESIGN: Retrospective case series at a university teaching hospital. PATIENTS: Fifty-three consecutive patients having 8-ply SIS mesh repair of ventral abdominal hernias. MAIN OUTCOME MEASURES: Early complications, reoperation, hernia recurrence, mesh or wound infection, or reaction. Outcomes reported and compared on an intention-to-treat basis. RESULTS: Patients were stratified by wound class: clean, clean-contaminated and contaminated, or dirty. Median follow-up was 14 months (range, 2-29 months) during which there were 22 complications (41%), 17 early reoperations (32%), 13 partial dehiscences (21%), 6 mesh reactions (11%), and 9 recurrent hernias (17%). Seven recurrent hernias (78%) in critically ill, patients with dirty wounds had the SIS mesh removed owing to infection or reoperation. In patients without SIS mesh removal or debridement, 1 (2.2%) of 44 developed a recurrent hernia at 6 months. Patients with dirty wounds were more likely to need early reoperation (P<.001), develop a complication (P<.01), partial wound dehiscence (P<.05), or recurrent hernia (P<.01) compared with patients with clean wounds. Critically ill patients were more likely to have hernia recurrence (P<.05), early reoperation (P<.001), and postoperative complications (P<.05). CONCLUSIONS: Eight-ply SIS mesh is safe in clean and clean-contaminated hernia repair with satisfactory short-term outcomes. However, delayed wound infection, repeated operation, and mesh debridement warrant cautious use of SIS mesh in critically ill patients and those with dirty wounds.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A comparison of suture repair with mesh repair for incisional hernia.
Luijendijk, R. W., Hop, W. C. J., van den Tol, M. P., de Lange, D. C. D., Braaksma, M. M. J., IJzermans, J. N. M., Boelhouwer, R. U., de Vries, B. C., Salu, M. K. M., Wereldsma, J. C. J., et al. (2000) · New England Journal of Medicine · doi:10.1056/nejm200008103430603 · Cited by 1,508
“Components Separation” Method for Closure of Abdominal-Wall Defects: An Anatomic and Clinical Study
Ramirez, O. M., Ruas, E., & Dellon, A. L. (1990) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-199009000-00023 · Cited by 1,374 · cited 1×
“In 3 patients this required performing a bilateral fascial release and components separation to obtain closure without tension.(24) Such a closure could not be achieved owing to the size of the hernia defect in 2 patients and the mesh was sewn to the margins of the defect as an inlay graft.”
Burger, J. W. A., Luijendijk, R. W., Hop, W. C. J., Halm, J. A., Verdaasdonk, E. G. G., & Jeekel, J. (2004) · Annals of Surgery · doi:10.1097/01.sla.0000141193.08524.e7 · Cited by 1,340
The treatment of complicated groin and incisional hernias
Stoppa, R. E. (1989) · World Journal of Surgery · doi:10.1007/bf01658869 · Cited by 883
The extracellular matrix as a scaffold for tissue reconstruction
Badylak, S. F. (2002) · Seminars in Cell & Developmental Biology · doi:10.1016/s1084952102000940 · Cited by 818 · cited 2×
“Such a sequence could potentially interfere with the ECMinduced wound-remodeling process that usually results in rapid stem cell ingrowth, angiogenesis of the wound, and eventual replacement of the ECM tissue graft.(30,43,44) Subcutaneous infection did not occur in either of the 2 patients who had an inlay mesh and, t…”
Laparoscopic Repair of Ventral Hernias: Nine Years’ Experience With 850 Consecutive Hernias
Heniford, B. T., Park, A., Ramshaw, B. J., & Voeller, G. (2003) · Annals of Surgery · doi:10.1097/01.sla.0000086662.49499.ab · Cited by 806
Xenogeneic extracellular matrix as a scaffold for tissue reconstruction
Badylak, S. F. (2004) · Transplant Immunology · doi:10.1016/j.trim.2003.12.016 · Cited by 747 · cited 1×
“Experimental evidence in animals has shown that the nature and timing of wound healing is altered by Surgisis ECM tissue grafts.(31,43,44,46,51) Therefore, it is quite possible that the time course and nature of infection in a wound with Surgisis mesh may also differ from traditional postoperative wound infections.”
XENOGENEIC EXTRACELLULAR MATRIX GRAFTS ELICIT A TH2-RESTRICTED IMMUNE RESPONSE1
Allman, A. J., McPherson, T. B., Badylak, S. F., Merrill, L. C., Kallakury, B., Sheehan, C., Raeder, R. H., & Metzger, D. W. (2001) · Transplantation · doi:10.1097/00007890-200106150-00024 · Cited by 388 · cited 1×
“For example, it has been reported that SIS mesh induces a Th2 inflammatory cytokine response.(45,46) It is further known that a predominant Th2 cytokine response causes local and systemic immune suppression.”
Voyles, C. R., Richardson, J. D., Bland, K. I., Tobin, G. R., FLINT, L. M., & Polk, H. C. (1981) · Annals of Surgery · doi:10.1097/00000658-198108000-00017 · Cited by 333
Morphologic Study of Small Intestinal Submucosa as a Body Wall Repair Device
Badylak, S., Kokini, K., Tullius, B., Simmons-Byrd, A., & Morff, R. (2002) · Journal of Surgical Research · doi:10.1006/jsre.2001.6349 · Cited by 311 · cited 1×
“Experimental evidence in animals has shown that the nature and timing of wound healing is altered by Surgisis ECM tissue grafts.(31,43,44,46,51) Therefore, it is quite possible that the time course and nature of infection in a wound with Surgisis mesh may also differ from traditional postoperative wound infections.”
Cited by
Breuing, K., Butler, C. E., Ferzoco, S., Franz, M., Hultman, C. S., Kilbridge, J. F., Rosen, M., Silverman, R. P., & Vargo, D. (2010) · Surgery · doi:10.1016/j.surg.2010.01.008 · Cited by 1,031
The extracellular matrix as a biologic scaffold material
Badylak, S. F. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.04.043 · Cited by 1,022
Efficacy of Anal Fistula Plug in Closure of Crohn's Anorectal Fistulas
O'Connor, L., Champagne, B. J., Ferguson, M. A., Orangio, G. R., Schertzer, M. E., & Armstrong, D. N. (2006) · Diseases of the Colon & Rectum · doi:10.1007/s10350-006-0695-y · Cited by 233
2017 update of the WSES guidelines for emergency repair of complicated abdominal wall hernias
Birindelli, A., Sartelli, M., Di Saverio, S., Coccolini, F., Ansaloni, L., van Ramshorst, G. H., Campanelli, G., Khokha, V., Moore, E. E., Peitzman, A., et al. (2017) · World Journal of Emergency Surgery · doi:10.1186/s13017-017-0149-y · Cited by 232
Use of human acellular dermal matrix in complex and contaminated abdominal wall reconstructions
Patton, J. H., Berry, S., & Kralovich, K. A. (2007) · The American Journal of Surgery · doi:10.1016/j.amjsurg.2006.09.021 · Cited by 211
Franklin, M. E., Treviño, J. M., Portillo, G., Vela, I., Glass, J. L., & González, J. J. (2008) · Surgical Endoscopy · doi:10.1007/s00464-008-0005-y · Cited by 173
Are Biologic Grafts Effective for Hernia Repair?: A Systematic Review of the Literature
Hiles, M., Record Ritchie, R. D., & Altizer, A. M. (2009) · Surgical Innovation · doi:10.1177/1553350609331397 · Cited by 172
Huerta, S., Varshney, A., Patel, P. M., Mayo, H. G., & Livingston, E. H. (2016) · JAMA Surgery · doi:10.1001/jamasurg.2015.5234 · Cited by 71
Metadata
- Authors
- Helton, W. S.
- Venue
- Archives of Surgery
- Publisher
- American Medical Association (AMA)
- Published
- 2005-06-01
- Volume
- 140
- Issue
- 6
- Pages
- 549
- ISSN
- 0004-0010 (ISSN-L)
- OpenAlex
- W2132021743
- Cited by
- 196
- References
- 43
- FWCI
- 16.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.