Endoscopic Complications: Results of the 1974 American Society for Gastrointestinal Endoscopy Survey
The DOI matches its Crossref record.
Abstract
Esophagogastroduodenoscopy (211,410 examinations) had a complication rate of 1.3/1,000 cases. Duodenoscopy with cannulation was performed 3,884 times and had a complication rate of 21.6/1,000 examinations. Diagnostic coloscopy (25,298 examinations) had a complication rate of 3.4/1,000. Polypectomies during coloscopy (6,124 cases) had a complication rate of 23.3/1,000 cases. Esophageal dilations (13,139 cases) had a complication rate of 4.25 with mercury bougies, and in 9,431 cases metal olives produced a complication rate of 6.1/1,000 treatments. Dilation for achalasia in 1,224 patients produced a complication rate of 18.4/1,000 procedures. Peritoneoscopy (4,404 examinations) produced a complication rate of 5.4/1,000 patients. The value of these diagnostic and therapeutic procedures is now well established but must be weighed against a potential risk of complications. (JAMA235:928-930, 1976)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A lexicon for endoscopic adverse events: report of an ASGE workshop
Cotton, P. B., Eisen, G. M., Aabakken, L., Baron, T. H., Hutter, M. M., Jacobson, B. C., Mergener, K., Nemcek, A., Petersen, B. T., Petrini, J. L., et al. (2010) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2009.10.027 · Cited by 2,464
Quality indicators for colonoscopy
Rex, D. K., Schoenfeld, P. S., Cohen, J., Pike, I. M., Adler, D. G., Fennerty, M. B., Lieb, J. G., Park, W. G., Rizk, M. K., Sawhney, M. S., et al. (2015) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2014.07.058 · Cited by 1,764
Quality Indicators for Colonoscopy
Rex, D. K., Schoenfeld, P. S., Cohen, J., Pike, I. M., Adler, D. G., Fennerty, B. M., Lieb, J. G., Park, W. G., Rizk, M. K., Sawhney, M. S., et al. (2015) · American Journal of Gastroenterology · doi:10.1038/ajg.2014.385 · Cited by 1,401
Rex, D. K., Bond, J. H., Winawer, S. J., Levin, T. R., Burt, R. W., Johnson, D. A., Kirk, L. M., Litlin, S., Lieberman, D. A., Waye, J. D., et al. (2002) · The American Journal of Gastroenterology · doi:10.1016/s0002-9270(02)04168-0 · Cited by 1,049
Quality Indicators for Colonoscopy
Rex, D. K., Petrini, J. L., Baron, T. H., Chak, A., Cohen, J., Deal, S. E., Hoffman, B., Jacobson, B. C., Mergener, K., Petersen, B. T., et al. (2006) · The American Journal of Gastroenterology · doi:10.1111/j.1572-0241.2006.00673.x · Cited by 845
SEWARD, J. B., KHANDHERIA, B. K., OH, J. K., ABEL, M. D., HUGHES, R. W., EDWARDS, W. D., NICHOLS, B. A., FREEMAN, W. K., & TAJIK, A. J. (1988) · Mayo Clinic Proceedings · doi:10.1016/s0025-6196(12)65529-3 · Cited by 791
Safety of Transesophageal Echocardiography
Hilberath, J. N., Oakes, D. A., Shernan, S. K., Bulwer, B. E., D’Ambra, M. N., & Eltzschig, H. K. (2010) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2010.08.013 · Cited by 612
Quality indicators for colonoscopy
Rex, D. K., Petrini, J. L., Baron, T. H., Chak, A., Cohen, J., Deal, S. E., Hoffman, B., Jacobson, B. C., Mergener, K., Petersen, B. T., et al. (2006) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2006.02.021 · Cited by 493
The National ASGE Survey on Upper Gastrointestinal Bleeding
Silverstein, F. E., Gilbert, D. A., Tedesco, F. J., Buenger, N. K., & Persing, J. (1981) · Gastrointestinal Endoscopy · doi:10.1016/s0016-5107(81)73156-0 · Cited by 461
Standards of Practice Committee, Dominitz, J. A., Eisen, G. M., Baron, T. H., Goldstein, J. L., Hirota, W. K., Jacobson, B. C., Johanson, J. F., Leighton, J. A., Mallery, J. S., et al. (2003) · Gastrointestinal Endoscopy · doi:10.1016/s0016-5107(03)80005-6 · Cited by 451
Complications of ERCP: a prospective study
Christensen, M., Matzen, P., Schulze, S., & Rosenberg, J. (2004) · Gastrointestinal Endoscopy · doi:10.1016/s0016-5107(04)02169-8 · Cited by 446
A national study of cardiopulmonary unplanned events after GI endoscopy
Sharma, V. K., Nguyen, C. C., Crowell, M. D., Lieberman, D. A., de Garmo, P., & Fleischer, D. E. (2007) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2006.12.040 · Cited by 428
Procedural success and complications of large-scale screening colonoscopy
Nelson, D. B., McQuaid, K. R., Bond, J. H., Lieberman, D. A., Weiss, D. G., & Johnston, T. K. (2002) · Gastrointestinal Endoscopy · doi:10.1067/mge.2002.121883 · Cited by 426
Gastroesophageal Reflux: Pathogenesis, Diagnosis, and Therapy
RICHTER, J. E., & CASTELL, D. O. (1982) · Annals of Internal Medicine · doi:10.7326/0003-4819-97-1-93 · Cited by 393
Rutter, M. D., East, J., Rees, C. J., Cripps, N., Docherty, J., Dolwani, S., Kaye, P. V., Monahan, K. J., Novelli, M. R., Plumb, A., et al. (2020) · Gut · doi:10.1136/gutjnl-2019-319858 · Cited by 380
Adverse events of upper GI endoscopy
Ben-Menachem, T., Decker, G. A., Early, D. S., Evans, J., Fanelli, R. D., Fisher, D. A., Fisher, L., Fukami, N., Hwang, J. H., Ikenberry, S. O., et al. (2012) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2012.03.252 · Cited by 378
Catalano, V., Labianca, R., Beretta, G. D., Gatta, G., de Braud, F., & Van Cutsem, E. (2009) · Critical Reviews in Oncology/Hematology · doi:10.1016/j.critrevonc.2009.01.004 · Cited by 365
Screening and Surveillance for Barrett Esophagus in High-Risk Groups: A CostUtility Analysis
Inadomi, J. M., Sampliner, R., Lagergren, J., Lieberman, D., Fendrick, A. M., & Vakil, N. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-3-200302040-00009 · Cited by 361
Barrett's esophagus: a new look at surveillance based on emerging estimates of cancer risk
Provenzale, D. (1999) · The American Journal of Gastroenterology · doi:10.1016/s0002-9270(99)00332-9 · Cited by 357
UK key performance indicators and quality assurance standards for colonoscopy
Rees, C. J., Thomas Gibson, S., Rutter, M. D., Baragwanath, P., Pullan, R., Feeney, M., & Haslam, N. (2016) · Gut · doi:10.1136/gutjnl-2016-312044 · Cited by 330
Adverse events in older patients undergoing colonoscopy: a systematic review and meta-analysis
Day, L. W., Kwon, A., Inadomi, J. M., Walter, L. C., & Somsouk, M. (2011) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2011.06.023 · Cited by 284
Colonoscopy completion and complication rates in a community gastroenterology practice
Rathgaber, S. W., & Wick, T. M. (2006) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2006.03.014 · Cited by 171
Hashimoto, T., Adachi, K., Ishimura, N., Hirakawa, K., Katsube, T., Kurotani, A., Hattori, S., & Kinoshita, Y. (2002) · Alimentary Pharmacology & Therapeutics · doi:10.1046/j.1365-2036.2002.01148.x · Cited by 38
Metadata
- Authors
- Silvis, S. E.
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 1976-03-01
- Volume
- 235
- Issue
- 9
- Pages
- 928
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W4243587440
- Cited by
- 488
- References
- 0
- FWCI
- 6.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.