The DOI matches its Crossref record.
Identification of the Critical Oxygen Delivery for Anaerobic Metabolism in Critically III Septic and Nonseptic Humans
Abstract
Objectives. —To determine the critical oxygen delivery threshold for anaerobic metabolism and to compare its value between septic and nonseptic critically ill patients. Design. —Cohort analytic study, consecutive sample. Setting. —Two tertiary care medical and surgical intensive care units in university hospitals. Patients. —Nine septic and nine nonseptic critically ill humans. A diagnosis of sepsis was established by the presence of sepsis syndrome, positive cultures obtained within 48 hours of study, and autopsy evidence of a source of infection. Methods and Interventions. —The O2consumption (determined by indirect calorimetry), O2delivery (calculated from the Fick equation), and concentration of arterial plasma lactate were simultaneously determined at 5-to 20-minute intervals while life support was discontinued. Main Outcome Measures. —Critical O2delivery, critical O2extraction ratio, and maximal O2extraction ratio. Results. —In all septic and eight nonseptic patients, O2delivery and O2consumption displayed a biphasic relationship over the range of O2delivery studied. There were no differences in critical O2delivery threshold (3.8±1.5 vs 4.5±1.3 mL·min-1·kg-1;P>.28), critical O2extraction ratio (0.61 ±0.05 vs 0.59±0.16;P>.64), and maximal O2extraction ratio (0.74±0.08 vs 0.80±0.11;P>.29) between septic and nonseptic patients. These data have greater than 90% power to detect a difference of 2 mL·min-1·kg-1in the critical O2delivery and 0.1 in the critical and maximal O2extraction ratios between the septic and nonseptic groups. Conclusions. —The critical O2delivery for anaerobic metabolism was identified from the biphasic relationship between O2delivery and O2consumption in individual humans. The critical O2delivery is considerably lower than previously reported in humans with the use of pooled group data. Sepsis does not alter the critical O2delivery for anaerobic metabolism or tissue O2extraction ability. Interventions to increase O2delivery to supranormal levels in critically ill humans in the hope of increasing O2consumption may be inappropriate. (JAMA. 1993;270:1724-1730)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cecconi, M., De Backer, D., Antonelli, M., Beale, R., Bakker, J., Hofer, C., Jaeschke, R., Mebazaa, A., Pinsky, M. R., Teboul, J. L., et al. (2014) · Intensive Care Medicine · doi:10.1007/s00134-014-3525-z · Cited by 1,767
Jansen, T. C., van Bommel, J., Schoonderbeek, F. J., Sleeswijk Visser, S. J., van der Klooster, J. M., Lima, A. P., Willemsen, S. P., & Bakker, J. (2010) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200912-1918oc · Cited by 894
Practice parameters for hemodynamic support of sepsis in adult patients: 2004 update
Hollenberg, S. M., Ahrens, T. S., Annane, D., Astiz, M. E., Chalfin, D. B., Dasta, J. F., Heard, S. O., Martin, C., Napolitano, L. M., Susla, G. M., et al. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000139761.05492.d6 · Cited by 521
Sepsis-associated hyperlactatemia
Garcia-Alvarez, M., Marik, P., & Bellomo, R. (2014) · Critical Care · doi:10.1186/s13054-014-0503-3 · Cited by 506
Clinical use of lactate monitoring in critically ill patients
Bakker, J., Nijsten, M. W., & Jansen, T. C. (2013) · Annals of Intensive Care · doi:10.1186/2110-5820-3-12 · Cited by 473
Metadata
- Authors
- Ronco, J. J.
- Venue
- JAMA: The Journal of the American Medical Association
- Publisher
- American Medical Association (AMA)
- Published
- 1993-10-13
- Volume
- 270
- Issue
- 14
- Pages
- 1724
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W4293877787
- Cited by
- 263
- References
- 0
- FWCI
- 9.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Identification of the Critical Oxygen Delivery for Anaerobic Metabolism in Critically III Septic and Nonseptic Humans. https://app.cochat.ai/papers/10.1001/jama.1993.03510140084034
- The paper
- Ronco, J. J. (1993). Identification of the Critical Oxygen Delivery for Anaerobic Metabolism in Critically III Septic and Nonseptic Humans. JAMA: The Journal of the American Medical Association. https://doi.org/10.1001/jama.1993.03510140084034
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.