Abstract

OBJECTIVES: To develop explicit, reliable appropriateness criteria for antiepileptic drug level monitoring and to assess the appropriateness of monitoring in one tertiary care institution. DESIGN: Appropriateness criteria derived from the literature and through expert opinion were used to evaluate a stratified random sample of antiepileptic drug level determinations obtained from chart review. SETTING: Tertiary care center performing more than 10,000 antiepileptic drug level determinations per year. PATIENTS: A total of 330 inpatients in whom antiepileptic drug levels were measured a total of 855 times. METHODS: Drug levels were assessed at least 200 times for each of four antiepileptic drugs (phenytoin, carbamazepine, phenobarbital, and valproic acid). MAIN OUTCOME MEASURES: The proportion of antiepileptic drug levels with an appropriate indication and, of those, the proportion sampled appropriately. RESULTS: Overall, 27% (95% confidence interval, 24% to 30%) of levels had an appropriate indication. Interrater agreement for appropriateness was substantial (kappa = 0.61). There was no significant difference in the appropriateness rate among the four drugs (range, 25% to 29%). Of the 624 antiepileptic drug level determinations considered inappropriate (73%), only four (0.6%) were more than 20% higher than the upper limit of normal, and none of the four patients had clinical signs of drug toxicity. A median of six levels (range, one through 69) was determined per patient, and the median interval between level determinations was 24 hours. Of the 27% of level determinations with an appropriate indication, 51% were sampled correctly, resulting in an overall appropriateness rate of 14%. CONCLUSIONS: Only 27% of antiepileptic drug level determinations had an appropriate indication, and half of these were not sampled correctly. Routine daily monitoring without pharmacological justification accounted for most of the inappropriate drug level determinations. Efforts to decrease inappropriate monitoring may result in substantial cost reductions without missing important clinical results.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jama.1995.03530200058038

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 102

Metadata

Authors
Schoenenberger, R. A.
Venue
JAMA: The Journal of the American Medical Association
Published
1995-11-22
Volume
274
Issue
20
Pages
1622
ISSN
  • 0002-9955 (ISSN-L)
  • 0098-7484
OpenAlex
W2081936161
Cited by
102
References
2
FWCI
4.51
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Appropriateness of Antiepileptic Drug Level Monitoring. https://app.cochat.ai/papers/10.1001/jama.1995.03530200058038
The paper
Schoenenberger, R. A. (1995). Appropriateness of Antiepileptic Drug Level Monitoring. JAMA: The Journal of the American Medical Association. https://doi.org/10.1001/jama.1995.03530200058038

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.