Context Bias: A Problem in Diagnostic Radiology
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To determine whether radiologists' interpretations of images are biased by their context and by prevalence of disease in other recently observed cases. METHODS: A test set of 24 right pulmonary arteriograms with a 33% prevalence of pulmonary emboli (PE) was assembled and embedded in 2 larger groups of films. Group A contained 16 additional arteriograms, all showing PE involving the right lung, so that total prevalence was 60%. Group B contained 16 additional arteriograms without PE so that total prevalence was 20%. Six radiologists were randomly assigned to see either group first and then "cross over" to review the other group after a hiatus of at least 8 weeks. The direction of changes in a 5-point rating scale for the 2 readings of each film in the test set was compared with the sign test; mean sensitivity, specificity, and areas under receiver operating characteristic (ROC) curves were compared with the paired t test. RESULTS: In the context of group A's higher disease prevalence, radiologists shifted more of their diagnoses toward higher suspicion than expected by chance (P=.03, sign test). In group A, mean sensitivity for diagnosing PE was significantly higher (75% vs 60%; P=.04), and area under the ROC curve was significantly larger (0.88 vs 0.82; P=.02). CONCLUSIONS: Radiologists' diagnoses are significantly influenced by the context of interpretation, even when spectrum and verification bias are avoided. This "context bias" effect is unique to the evaluation of subjectively interpreted tests, and illustrates the difficulty of obtaining unbiased estimates of diagnostic accuracy for both new and existing technologies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The meaning and use of the area under a receiver operating characteristic (ROC) curve.
Hanley, J. A., & McNeil, B. J. (1982) · Radiology · doi:10.1148/radiology.143.1.7063747 · Cited by 21,856
Problems of Spectrum and Bias in Evaluating the Efficacy of Diagnostic Tests
Ransohoff, D. F., & Feinstein, A. R. (1978) · New England Journal of Medicine · doi:10.1056/nejm197810262991705 · Cited by 1,734
(2005) · Integrative Oncology · doi:10.1201/9780203088319-19 · Cited by 1,579
Ten- to Fourteen-Year Effect of Screening on Breast Cancer Mortality 2
(1982) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/69.2.349 · Cited by 840
Breast Cancer Detection Demonstration Project: Five-Year Summary Report
Baker, L. H. (1982) · CA: A Cancer Journal for Clinicians · doi:10.3322/canjclin.32.4.194 · Cited by 694
Variability in Radiologists' Interpretations of Mammograms
Elmore, J. G., Wells, C. K., Lee, C. H., Howard, D. H., & Feinstein, A. R. (1994) · New England Journal of Medicine · doi:10.1056/nejm199412013312206 · Cited by 601
Biases in the assessment of diagnostic tests
Begg, C. B. (1987) · Statistics in Medicine · doi:10.1002/sim.4780060402 · Cited by 496
GREENES, R. A., & BEGG, C. B. (1985) · Investigative Radiology · doi:10.1097/00004424-198510000-00018 · Cited by 292
Lachs, M. S., Nachamkin, I., Edelstein, P. H., Goldman, J., Feinstein, A. R., & Schwartz, J. S. (1992) · Annals of Internal Medicine · doi:10.7326/0003-4819-117-2-135 · Cited by 261
Calcification of coronary arteries: detection and quantification with double-helix CT.
Shemesh, J., Apter, S., Rozenman, J., Lusky, A., Rath, S., Itzchak, Y., & Motro, M. (1995) · Radiology · doi:10.1148/radiology.197.3.7480756 · Cited by 165
Early-stage rheumatoid arthritis: diagnostic accuracy of MR imaging.
Sugimoto, H., Takeda, A., Masuyama, J., & Furuse, M. (1996) · Radiology · doi:10.1148/radiology.198.1.8539375 · Cited by 163
The Poor Quality of Early Evaluations of Magnetic Resonance Imaging
Cooper, L. S., Chalmers, T. C., McCally, M., Berrier, J., & Sacks, H. S. (1988) · JAMA · doi:10.1001/jama.1988.03720220023019 · Cited by 137
Brenner, H., & Gefeller, O. (1993) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a116805 · Cited by 104
The inadequacy of binary models for the clinical reality of three-zone diagnostic decisions
Feinstein, A. R. (1990) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(90)90064-v · Cited by 96
Impact of clinical history on fracture detection with radiography.
Berbaum, K. S., el-Khoury, G. Y., Franken, E. A., Kathol, M. H., Montgomery, W. J., & Hesson, W. (1988) · Radiology · doi:10.1148/radiology.168.2.3393672 · Cited by 96
Castagnone, D., Rivolta, R., Rescalli, S., Baldini, M., Tozzi, R., & CANTALAMESSA, L. (1996) · American Journal of Roentgenology · doi:10.2214/ajr.166.1.8571877 · Cited by 91
The Clinical History as a Factor in Roentgenogram Interpretation
Schreiber, M. H. (1963) · JAMA · doi:10.1001/jama.1963.03060050077027 · Cited by 90
McNeil, B. J., Hanley, J. A., Funkenstein, H. H., & Wallman, J. (1983) · Radiology · doi:10.1148/radiology.149.1.6611955 · Cited by 86
Kang, E. Y., Staples, C. A., McGuinness, G., Primack, S. L., & Müller, N. L. (1996) · American Journal of Roentgenology · doi:10.2214/ajr.166.1.8571866 · Cited by 77
Hepatic tumors: quantitative tissue characterization with MR imaging.
Egglin, T. K., Rummeny, E. J., Dd, S., WITTENBERG, J., Saini, S., & Ferrucci, J. T. (1990) · Radiology · doi:10.1148/radiology.176.1.2162067 · Cited by 66
Self-citationCommunicating the significance of radiologic test results: the likelihood ratio
Black, W., & Armstrong, P. (1986) · American Journal of Roentgenology · doi:10.2214/ajr.147.6.1313 · Cited by 64
Effect of Clinical History on the Interpretation of Chest Radiographs in Childhood Bronchiolitis
Babcook, C. J., Norman, G. R., & Coblentz, C. L. (1993) · Investigative Radiology · doi:10.1097/00004424-199303000-00005 · Cited by 29
Cited by
Moher, D., Schulz, K. F., & Altman, D. G. (2001) · BMC Medical Research Methodology · doi:10.1186/1471-2288-1-2 · Cited by 2,755
The STARD Statement for Reporting Studies of Diagnostic Accuracy: Explanation and Elaboration
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Moher, D., Rennie, D., de Vet, H. C. W., & Lijmer, J. G. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00012-w1 · Cited by 1,124
“Readers are more likely to interpret results from (subjective) tests as abnormal in settings with higher prevalences of the target condition, a tendency known as context bias (47).”
Sources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798
Noninvasive Diagnosis of Deep Venous Thrombosis
Kearon, C., Julian, J. A., Math, M., Newman, T. E., & Ginsberg, J. S. (1998) · Annals of Internal Medicine · doi:10.7326/0003-4819-128-8-199804150-00011 · Cited by 690
Low target prevalence is a stubborn source of errors in visual search tasks.
Wolfe, J. M., Horowitz, T. S., Van Wert, M. J., Kenner, N. M., Place, S. S., & Kibbi, N. (2007) · Journal of Experimental Psychology: General · doi:10.1037/0096-3445.136.4.623 · Cited by 418
Metadata
- Authors
- Egglin, T. K. P.
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 1996-12-04
- Volume
- 276
- Issue
- 21
- Pages
- 1752
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W1984992264
- Cited by
- 192
- References
- 22
- FWCI
- 4.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.