Dried Blood Spot Real-time Polymerase Chain Reaction Assays to Screen Newborns for Congenital Cytomegalovirus Infection

Open access
Boppana, Suresh B.·2010·JAMA

Abstract

CONTEXT: Reliable methods to screen newborns for congenital cytomegalovirus (CMV) infection are needed for identification of infants at increased risk of hearing loss. Since dried blood spots (DBS) are routinely collected for metabolic screening from all newborns in the United States, there has been interest in using DBS polymerase chain reaction (PCR)-based methods for newborn CMV screening. OBJECTIVE: To determine the diagnostic accuracy of DBS real-time PCR assays for newborn CMV screening. DESIGN, SETTING, AND PARTICIPANTS: Between March 2007 and May 2008, infants born at 7 US medical centers had saliva specimens tested by rapid culture for early antigen fluorescent foci. Results of saliva rapid culture were compared with a single-primer (March 2007-December 2007) and a 2-primer DBS real-time PCR (January 2008-May 2008). Infants whose specimens screened positive on rapid culture or PCR had congenital infection confirmed by the reference standard method with rapid culture testing on saliva or urine. MAIN OUTCOME MEASURES: Sensitivity, specificity, and positive and negative likelihood ratios (LRs) of single-primer and 2-primer DBS real-time PCR assays for identifying infants with confirmed congenital CMV infection. RESULTS: Congenital CMV infection was confirmed in 92 of 20,448 (0.45%; 95% confidence interval [CI], 0.36%-0.55%) infants. Ninety-one of 92 infants had positive results on saliva rapid culture. Of the 11,422 infants screened using the single-primer DBS PCR, 17 of 60 (28%) infants had positive results with this assay, whereas, among the 9026 infants screened using the 2-primer DBS PCR, 11 of 32 (34%) screened positive. The single-primer DBS PCR identified congenital CMV infection with a sensitivity of 28.3% (95% CI, 17.4%-41.4%), specificity of 99.9% (95% CI, 99.9%-100%), positive LR of 803.7 (95% CI, 278.7-2317.9), and negative LR of 0.7 (95% CI, 0.6-0.8). The positive and negative predictive values of the single-primer DBS PCR were 80.9% (95% CI, 58.1%-94.5%) and 99.6% (95% CI, 99.5%-99.7%), respectively. The 2-primer DBS PCR assay identified infants with congenital CMV infection with a sensitivity of 34.4% (95% CI, 18.6%-53.2%), specificity of 99.9% (95% CI, 99.9%-100.0%), positive LR of 3088.9 (95% CI, 410.8-23 226.7), and negative LR of 0.7 (95% CI, 0.5-0.8). The positive and negative predictive values of the 2-primer DBS PCR were 91.7% (95% CI, 61.5%-99.8%) and 99.8% (95% CI, 99.6%-99.9%), respectively. CONCLUSION: Among newborns, CMV testing with DBS real-time PCR compared with saliva rapid culture had low sensitivity, limiting its value as a screening test.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jama.2010.423

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 20 references

Cited by

See all 383

Metadata

Authors
Boppana, S. B.
Venue
JAMA
Published
2010-04-14
Volume
303
Issue
14
Pages
1375
ISSN
  • 0002-9955 (ISSN-L)
  • 0098-7484
OpenAlex
W2152900899
Cited by
383
References
20
FWCI
17.19
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Dried Blood Spot Real-time Polymerase Chain Reaction Assays to Screen Newborns for Congenital Cytomegalovirus Infection. https://app.cochat.ai/papers/10.1001/jama.2010.423
The paper
Boppana, S. B. (2010). Dried Blood Spot Real-time Polymerase Chain Reaction Assays to Screen Newborns for Congenital Cytomegalovirus Infection. JAMA. https://doi.org/10.1001/jama.2010.423

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.