Outcomes Following Transcatheter Aortic Valve Replacement in the United States
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
IMPORTANCE: Transcatheter aortic valve replacement (TAVR) was approved by the US Food and Drug Administration for the treatment of severe, symptomatic aortic stenosis and inoperable status (in 2011) and high-risk but operable status (starting in 2012). A national registry (the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy [STS/ACC TVT] Registry) was initiated to meet a condition for Medicare coverage and also facilitates outcome assessment and comparison with other trials and international registries. OBJECTIVE: To report the initial US commercial experience with TAVR. DESIGN, SETTING, AND PARTICIPANTS: We obtained results from all eligible US TAVR cases (n=7710) from 224 participating registry hospitals following the Edwards Sapien XT device commercialization (November 2011-May 2013). MAIN OUTCOMES AND MEASURES: Primary outcomes included all-cause in-hospital mortality and stroke following TAVR. Secondary analyses included procedural complications and outcomes by clinical indication and access site. Device implantation success was defined as successful vascular access, deployment of a single device in the proper anatomic position, appropriate valve function without either moderate or severe AR, and successful retrieval of the delivery system. Thirty-day outcomes are presented for a representative 3133 cases (40.6%) at 114 centers with at least 80% complete follow-up reporting. RESULTS: The 7710 patients who underwent TAVR included 1559 (20%) cases that were inoperable and 6151 (80%) cases that were high-risk but operable. The median age was 84 years (interquartile range [IQR], 78-88 years); 3783 patients (49%) were women and the median STS predicted risk of mortality was 7% (IQR, 5%-11%). At baseline, 2176 patients (75%) were either not at all satisfied (1297 patients [45%]) or mostly dissatisfied (879 patients [30%]) with their symptom status; 2198 (72%) had a 5-m walk time longer than 6 seconds (slow gait speed). The most common vascular access approach was transfemoral (4972 patients [64%]), followed by transapical (2197 patients [29%]) and other alternative approaches (536 patients [7%]); successful device implantation occurred in 7069 patients (92%; 95% CI, 91%-92%). The observed incidence of in-hospital mortality was 5.5% (95% CI, 5.0%-6.1%). Other major complications included stroke (2.0%; 95% CI, 1.7%-2.4%), dialysis-dependent renal failure (1.9%; 95% CI, 1.6%-2.2%), and major vascular injury (6.4%; 95% CI, 5.8%-6.9%). Median hospital stay was 6 days (IQR, 4-10 days), with 4613 (63%) discharged home. Among patients with available follow-up at 30 days (n=3133), the incidence of mortality was 7.6% (95% CI, 6.7%-8.6%) (noncardiovascular cause, 52%); a stroke had occurred in 2.8% (95% CI, 2.3%-3.5%), new dialysis in 2.5% (95% CI, 2.0%-3.1%), and reintervention in 0.5% (95% CI, 0.3%-0.8%). CONCLUSIONS AND RELEVANCE: Among patients undergoing TAVR at US centers in the STS/ACC TVT Registry, device implantation success was achieved in 92% of cases, the overall in-hospital mortality rate was 5.5%, and the stroke rate was 2.0%. Although these postmarket US approval findings are comparable with prior published trial data and international experience, long-term follow-up is essential to assess continued efficacy and safety. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT01737528.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery
Leon, M. B., Smith, C. R., Mack, M., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1008232 · Cited by 7,205
Self-citationTranscatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients
Smith, C. R., Leon, M. B., Mack, M. J., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1103510 · Cited by 6,345
Self-citationKappetein, A. P., Head, S. J., Généreux, P., Piazza, N., Mieghem, N. M. V., Blackstone, E., Brott, T., Cohen, D., Cutlip, D. E., van Es, G., et al. (2012) · doi:10.48350/15011 · Cited by 3,368
Self-citationUpdated Standardized Endpoint Definitions for Transcatheter Aortic Valve Implantation
Kappetein, A. P., Head, S. J., Généreux, P., Piazza, N., van Mieghem, N. M., Blackstone, E. H., Brott, T. G., Cohen, D. J., Cutlip, D. E., van Es, G.-A., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.09.001 · Cited by 1,668
Self-citationRegistry of Transcatheter Aortic-Valve Implantation in High-Risk Patients
Gilard, M., Eltchaninoff, H., Iung, B., Donzeau-Gouge, P., Chevreul, K., Fajadet, J., Leprince, P., Leguerrier, A., Lievre, M., Prat, A., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1114705 · Cited by 1,228
Leon, M. B., Piazza, N., Nikolsky, E., Blackstone, E. H., Cutlip, D. E., Kappetein, A. P., Krucoff, M. W., Mack, M., Mehran, R., Miller, C., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq406 · Cited by 1,219
Self-citationKappetein, A. P., Head, S. J., Généreux, P., Piazza, N., van Mieghem, N. M., Blackstone, E. H., Brott, T. G., Cohen, D. J., Cutlip, D. E., van Es, G.-A., et al. (2013) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2012.09.002 · Cited by 918
Self-citationMoat, N. E., Ludman, P., de Belder, M. A., Bridgewater, B., Cunningham, A. D., Young, C. P., Thomas, M., Kovac, J., Spyt, T., MacCarthy, P. A., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.08.050 · Cited by 884 · cited 1×
“Hybrid catheterization laboratory 2165 (28) 1124 (29) 516 (22) 410 (36) 115 (27)”
Thomas, M., Schymik, G., Walther, T., Himbert, D., Lefèvre, T., Treede, H., Eggebrecht, H., Rubino, P., Michev, I., Lange, R., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.907402 · Cited by 875
Standardized Endpoint Definitions for Transcatheter Aortic Valve Implantation Clinical Trials
Leon, M. B., Piazza, N., Nikolsky, E., Blackstone, E. H., Cutlip, D. E., Kappetein, A. P., Krucoff, M. W., Mack, M., Mehran, R., Miller, C., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.12.005 · Cited by 733
Self-citation
Cited by
Transcatheter or Surgical Aortic-Valve Replacement in Intermediate-Risk Patients
Leon, M. B., Smith, C. R., Mack, M. J., Makkar, R. R., Svensson, L. G., Kodali, S. K., Thourani, V. H., Tuzcu, E. M., Miller, D. C., Herrmann, H. C., et al. (2016) · New England Journal of Medicine · doi:10.1056/nejmoa1514616 · Cited by 5,053
Self-citationTranscatheter Aortic-Valve Replacement with a Self-Expanding Prosthesis
Adams, D. H., Popma, J. J., Reardon, M. J., Yakubov, S. J., Coselli, J. S., Deeb, G. M., Gleason, T. G., Buchbinder, M., Hermiller, J., Kleiman, N. S., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1400590 · Cited by 2,902
Mack, M. J., Leon, M. B., Smith, C. R., Miller, D. C., Moses, J. W., Tuzcu, E. M., Webb, J. G., Douglas, P. S., Anderson, W. N., Blackstone, E. H., et al. (2015) · The Lancet · doi:10.1016/s0140-6736(15)60308-7 · Cited by 1,739
Self-citationPopma, J. J., Adams, D. H., Reardon, M. J., Yakubov, S. J., Kleiman, N. S., Heimansohn, D., Hermiller, J., Hughes, G. C., Harrison, J. K., Coselli, J., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.02.556 · Cited by 1,040
Kapadia, S. R., Leon, M. B., Makkar, R. R., Tuzcu, E. M., Svensson, L. G., Kodali, S., Webb, J. G., Mack, M. J., Douglas, P. S., Thourani, V. H., et al. (2015) · The Lancet · doi:10.1016/s0140-6736(15)60290-2 · Cited by 867
Self-citationBlanke, P., Weir-McCall, J. R., Achenbach, S., Delgado, V., Hausleiter, J., Jilaihawi, H., Marwan, M., Nørgaard, B. L., Piazza, N., Schoenhagen, P., et al. (2019) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2018.12.003 · Cited by 610
Blanke, P., Weir-McCall, J. R., Achenbach, S., Delgado, V., Hausleiter, J., Jilaihawi, H., Marwan, M., Norgaard, B. L., Piazza, N., Schoenhagen, P., et al. (2019) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2018.11.008 · Cited by 543
Grover, F. L., Vemulapalli, S., Carroll, J. D., Edwards, F. H., Mack, M. J., Thourani, V. H., Brindis, R. G., Shahian, D. M., Ruiz, C. E., Jacobs, J. P., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.11.033 · Cited by 496
Self-citationYoon, S.-H., Bleiziffer, S., De Backer, O., Delgado, V., Arai, T., Ziegelmueller, J., Barbanti, M., Sharma, R., Perlman, G. Y., Khalique, O. K., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.03.017 · Cited by 489
Multimorbidity in Older Adults With Cardiovascular Disease
Forman, D. E., Maurer, M. S., Boyd, C., Brindis, R., Salive, M. E., Horne, F. M., Bell, S. P., Fulmer, T., Reuben, D. B., Zieman, S., et al. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.03.022 · Cited by 484
Self-citationClinical Outcomes at 1 Year Following Transcatheter Aortic Valve Replacement
Holmes, D. R., Brennan, J. M., Rumsfeld, J. S., Dai, D., O’Brien, S. M., Vemulapalli, S., Edwards, F. H., Carroll, J., Shahian, D., Grover, F., et al. (2015) · JAMA · doi:10.1001/jama.2015.1474 · Cited by 477
Self-citationPerioperative Results and Complications in 15,964 Transcatheter Aortic Valve Replacements
Walther, T., Hamm, C. W., Schuler, G., Berkowitsch, A., Kötting, J., Mangner, N., Mudra, H., Beckmann, A., Cremer, J., Welz, A., et al. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.03.034 · Cited by 402
“To evaluate specific outcomes and potential complications of T-AVI procedures there are several options: well-documented, randomized clinical trials that may include a selected patient population only (19-21), single- or multi-center nonrandomized studies (22), and broader registry data (23-26) that may lack some info…”
BackgroundTemporal Trends in Transcatheter Aortic Valve Replacement in France
Auffret, V., Lefevre, T., Van Belle, E., Eltchaninoff, H., Iung, B., Koning, R., Motreff, P., Leprince, P., Verhoye, J. P., Manigold, T., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.04.053 · Cited by 369
Kodali, S., Thourani, V. H., White, J., Malaisrie, S. C., Lim, S., Greason, K. L., Williams, M., Guerrero, M., Eisenhauer, A. C., Kapadia, S., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw112 · Cited by 352
Self-citationFadahunsi, O. O., Olowoyeye, A., Ukaigwe, A., Li, Z., Vora, A. N., Vemulapalli, S., Elgin, E., & Donato, A. (2016) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2016.07.026 · Cited by 335
Makkar, R. R., Yoon, S.-H., Leon, M. B., Chakravarty, T., Rinaldi, M., Shah, P. B., Skipper, E. R., Thourani, V. H., Babaliaros, V., Cheng, W., et al. (2019) · JAMA · doi:10.1001/jama.2019.7108 · Cited by 316
Self-citationMulticenter Evaluation of a Next-Generation Balloon-Expandable Transcatheter Aortic Valve
Webb, J., Gerosa, G., Lefèvre, T., Leipsic, J., Spence, M., Thomas, M., Thielmann, M., Treede, H., Wendler, O., & Walther, T. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.09.026 · Cited by 313
Ludman, P. F., Moat, N., de Belder, M. A., Blackman, D. J., Duncan, A., Banya, W., MacCarthy, P. A., Cunningham, D., Wendler, O., Marlee, D., et al. (2015) · Circulation · doi:10.1161/circulationaha.114.013947 · Cited by 282
Annual Outcomes With Transcatheter Valve Therapy
Holmes, D. R., Nishimura, R. A., Grover, F. L., Brindis, R. G., Carroll, J. D., Edwards, F. H., Peterson, E. D., Rumsfeld, J. S., Shahian, D. M., Thourani, V. H., et al. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.10.021 · Cited by 263
Self-citationHahn, R. T. (2016) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.116.005332 · Cited by 252
Effect of Availability of Transcatheter Aortic-Valve Replacement on Clinical Practice
Reinöhl, J., Kaier, K., Reinecke, H., Schmoor, C., Frankenstein, L., Vach, W., Cribier, A., Beyersdorf, F., Bode, C., & Zehender, M. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1500893 · Cited by 232
Transcaval Access and Closure for Transcatheter Aortic Valve Replacement
Greenbaum, A. B., Babaliaros, V. C., Chen, M. Y., Stine, A. M., Rogers, T., O’Neill, W. W., Paone, G., Thourani, V. H., Muhammad, K. I., Leonardi, R. A., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.10.024 · Cited by 226
“Despite a paucity of randomized data on alternate extra-thoracic access such as trans-carotid, subclavian or trans-axillary, single center experience suggests these approaches compare favorably to transthoracic, with acceptable rates of bleeding and vascular access complications (17,22,23).”
Auffret, V., Regueiro, A., Del Trigo, M., Abdul-Jawad Altisent, O., Campelo-Parada, F., Chiche, O., Puri, R., & Rodés-Cabau, J. (2016) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.05.065 · Cited by 201
Caval-Aortic Access to Allow Transcatheter Aortic Valve Replacement in Otherwise Ineligible Patients
Greenbaum, A. B., O'Neill, W. W., Paone, G., Guerrero, M. E., Wyman, J. F., Cooper, R. L., & Lederman, R. J. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.04.015 · Cited by 198
Initial Experience With Commercial Transcatheter Mitral Valve Repair in the United States
Sorajja, P., Mack, M., Vemulapalli, S., Holmes, D. R., Stebbins, A., Kar, S., Lim, D. S., Thourani, V., McCarthy, P., Kapadia, S., et al. (2016) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.12.054 · Cited by 185
Self-citationHalim, S. A., Edwards, F. H., Dai, D., Li, Z., Mack, M. J., Holmes, D. R., Tuzcu, E. M., Thourani, V. H., Harrison, J. K., & Brennan, J. M. (2020) · Circulation · doi:10.1161/circulationaha.119.040333 · Cited by 171
Self-citationBavaria, J. E., Tommaso, C. L., Brindis, R. G., Carroll, J. D., Deeb, G. M., Feldman, T. E., Gleason, T. G., Horlick, E. M., Kavinsky, C. J., Kumbhani, D. J., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.07.002 · Cited by 160
Self-citation
Metadata
- Authors
- Mack, M. J., Brennan, J. M., Brindis, R., Carroll, J., Edwards, F., Grover, F., Shahian, D., Tuzcu, E. M., Peterson, E. D., Rumsfeld, J. S., Hewitt, K., Shewan, C., Michaels, J., Christensen, B., Christian, A., O’Brien, S., & Holmes, D.
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 2013-11-20
- Volume
- 310
- Issue
- 19
- Pages
- 2069
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W1938921375
- Cited by
- 474
- References
- 17
- FWCI
- 48.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.