Importance: Biotinylated antibodies and analogues, with their strong binding to streptavidin, are used in many clinical laboratory tests. Excess biotin in blood due to supplemental biotin ingestion may affect biotin-streptavidin binding, leading to potential clinical misinterpretation. However, the degree of interference remains undefined in healthy adults. Objective: To assess performance of specific biotinylated immunoassays after 7 days of ingesting 10 mg/d of biotin, a dose common in over-the-counter supplements for healthy adults. Design, Setting, and Participants: Nonrandomized crossover trial involving 6 healthy adults who were treated at an academic medical center research laboratory. Exposure: Administration of 10 mg/d of biotin supplementation for 7 days. Main Outcomes and Measures: Analyte concentrations were compared with baseline (day 0) measures on the seventh day of biotin treatment and 7 days after treatment had stopped (day 14). The 11 analytes included 9 hormones (ie, thyroid-stimulating hormone, total thyroxine, total triiodothyronine, free thyroxine, free triiodothyronine, parathyroid hormone, prolactin, N-terminal pro-brain natriuretic peptide, 25-hydroxyvitamin D) and 2 nonhormones (prostate-specific antigen and ferritin). A total of 37 immunoassays for the 11 analytes were evaluated on 4 diagnostic systems, including 23 assays that incorporated biotin and streptavidin components and 14 assays that did not include biotin and streptavidin components and served as negative controls. Results: Among the 2 women and 4 men (mean age, 38 years [range, 31-45 years]) who took 10 mg/d of biotin for 7 days, biotin ingestion-associated interference was found in 9 of the 23 (39%) biotinylated assays compared with none of the 14 nonbiotinylated assays (P = .007). Results from 5 of 8 biotinylated (63%) competitive immunoassays tested falsely high and results from 4 out of 15 (27%) biotinylated sandwich immunoassays tested falsely low. Conclusions and Relevance: In this preliminary study of 6 healthy adult participants and 11 hormone and nonhormone analytes measured by 37 immunoassays, ingesting 10 mg/d of biotin for 1 week was associated with potentially clinically important assay interference in some but not all biotinylated assays studied. These findings should be considered for patients taking biotin supplements before ordering blood tests or when interpreting results. Trial Registration: clinicaltrials.gov Identifier: NCT03034707.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jama.2017.13705

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 132

Metadata

Authors
Li, D., Radulescu, A., Shrestha, R. T., Root, M., Karger, A. B., Killeen, A. A., Hodges, J. S., Fan, S.-L., Ferguson, A., Garg, U., Sokoll, L. J., & Burmeister, L. A.
Venue
JAMA
Published
2017-09-26
Volume
318
Issue
12
Pages
1150
ISSN
  • 0002-9955 (ISSN-L)
  • 0098-7484
OpenAlex
W2758889989
Cited by
132
References
3
FWCI
12.36
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Association of Biotin Ingestion With Performance of Hormone and Nonhormone Assays in Healthy Adults. https://app.cochat.ai/papers/10.1001/jama.2017.13705
The paper
Li, D., Radulescu, A., Shrestha, R. T., Root, M., Karger, A. B., Killeen, A. A., Hodges, J. S., Fan, S.-L., Ferguson, A., Garg, U., Sokoll, L. J., & Burmeister, L. A. (2017). Association of Biotin Ingestion With Performance of Hormone and Nonhormone Assays in Healthy Adults. JAMA. https://doi.org/10.1001/jama.2017.13705

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.