The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Effect of Use of a Bougie vs Endotracheal Tube and Stylet on First-Attempt Intubation Success Among Patients With Difficult Airways Undergoing Emergency Intubation: A Randomized Clinical Trial
Open accessAbstract
Importance: The tracheal tube introducer, known as the bougie, is typically used to aid tracheal intubation in poor laryngoscopic views or after intubation attempts fail. The effect of routine bougie use on first-attempt intubation success is unclear. Objective: To compare first attempt intubation success facilitated by the bougie vs the endotracheal tube + stylet. Design, Setting, and Patients: The Bougie Use in Emergency Airway Management (BEAM) trial was a randomized clinical trial conducted from September 2016 through August 2017 in the emergency department at Hennepin County Medical Center, an urban, academic department in Minneapolis, Minnesota, where emergency physicians perform all endotracheal intubations. Included patients were 18 years and older who were consecutively admitted to the emergency department and underwent emergency orotracheal intubation with a Macintosh laryngoscope blade for respiratory arrest, difficulty breathing, or airway protection. Interventions: Patients were randomly assigned to undergo the initial intubation attempt facilitated by bougie (n = 381) or endotracheal tube + stylet (n = 376). Main Outcomes and Measures: The primary outcome was first-attempt intubation success in patients with at least 1 difficult airway characteristic (body fluids obscuring the laryngeal view, airway obstruction or edema, obesity, short neck, small mandible, large tongue, facial trauma, or the need for cervical spine immobilization). Secondary outcomes were first-attempt success in all patients, first-attempt intubation success without hypoxemia, first-attempt duration, esophageal intubation, and hypoxemia. Results: Among 757 patients who were randomized (mean age, 46 years; women, 230 [30%]), 757 patients (100%) completed the trial. Among the 380 patients with at least 1 difficult airway characteristic, first-attempt intubation success was higher in the bougie group (96%) than in the endotracheal tube + stylet group (82%) (absolute between-group difference, 14% [95% CI, 8% to 20%]). Among all patients, first-attempt intubation success in the bougie group (98%) was higher than the endotracheal tube + stylet group (87%) (absolute difference, 11% [95% CI, 7% to 14%]). The median duration of the first intubation attempt (38 seconds vs 36 seconds) and the incidence of hypoxemia (13% vs 14%) did not differ significantly between the bougie and endotracheal tube + stylet groups. Conclusions and Relevance: In this emergency department, use of a bougie compared with an endotracheal tube + stylet resulted in significantly higher first-attempt intubation success among patients undergoing emergency endotracheal intubation. However, these findings should be considered provisional until the generalizability is assessed in other institutions and settings. Trial Registration: clinicaltrials.gov Identifier: NCT02902146.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Emergency Tracheal Intubation: Complications Associated with Repeated Laryngoscopic Attempts
Mort, T. C. (2004) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000122825.04923.15 · Cited by 995
Sakles, J. C., Chiu, S., Mosier, J., Walker, C., & Stolz, U. (2013) · Academic Emergency Medicine · doi:10.1111/acem.12055 · Cited by 565
Techniques, Success, and Adverse Events of Emergency Department Adult Intubations
Brown, C. A., Bair, A. E., Pallin, D. J., & Walls, R. M. (2015) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2014.10.036 · Cited by 431
Hasegawa, K., Shigemitsu, K., Hagiwara, Y., Chiba, T., Watase, H., Brown, C. A., & Brown, D. F. M. (2012) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2012.04.005 · Cited by 312
Nolan, J. P., & Wilson, M. E. (1993) · Anaesthesia · doi:10.1111/j.1365-2044.1993.tb07133.x · Cited by 271
Combes, X., Le Roux, B., Suen, P., Dumerat, M., Motamed, C., Sauvat, S., Duvaldestin, P., & Dhonneur, G. (2004) · Anesthesiology · doi:10.1097/00000542-200405000-00016 · Cited by 224
The Complexities of Tracheal Intubation With Direct Laryngoscopy and Alternative Intubation Devices
Levitan, R. M., Heitz, J. W., Sweeney, M., & Cooper, R. M. (2011) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2010.05.035 · Cited by 194
Sakles, J. C., Mosier, J., Chiu, S., Cosentino, M., & Kalin, L. (2012) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2012.03.031 · Cited by 192
Amathieu, R., Combes, X., Abdi, W., Housseini, L. E., Rezzoug, A., Dinca, A., SLAVOV, V., Bloc, S., & Dhonneur, G. (2010) · Anesthesiology · doi:10.1097/aln.0b013e318201c44f · Cited by 148
Simulated difficult intubation: Comparison of the gum elastic bougie and the stylet
Gataure, P. S., Vaughan, R. S., & Latto, I. P. (1996) · Anaesthesia · doi:10.1111/j.1365-2044.1996.tb14961.x · Cited by 143
Successful difficult intubation
KIDD, J. F., Dyson, A., & Latto, I. P. (1988) · Anaesthesia · doi:10.1111/j.1365-2044.1988.tb06625.x · Cited by 142
Park, L., Zeng, I. S. L., & Brainard, A. H. (2016) · Emergency Medicine Australasia · doi:10.1111/1742-6723.12704 · Cited by 140
Successful difficult intubation Tracheal tube placement over a gum‐elastic bougie
Dogra, S., Falconer, R., & Latto, I. P. (1990) · Anaesthesia · doi:10.1111/j.1365-2044.1990.tb14454.x · Cited by 135
Survey of the use of the gum elastic bougie in clinical practice
Latto, I. P., Stacey, M. R. W., Mecklenburgh, J. S., & Vaughan, R. S. (2002) · Anaesthesia · doi:10.1046/j.1365-2044.2002.02411.x · Cited by 125
Sakles, J. C., Patanwala, A. E., Mosier, J. M., & Dicken, J. (2013) · Internal and Emergency Medicine · doi:10.1007/s11739-013-0995-x · Cited by 105
Rognås, L. K., Hansen, T. M., Kirkegaard, H., & Tønnesen, E. (2013) · Scandinavian Journal of Trauma Resuscitation and Emergency Medicine · doi:10.1186/1757-7241-21-58 · Cited by 93
The Bougie and First-Pass Success in the Emergency Department
Driver, B. E., Dodd, K. W., Klein, L. R., Buckley, R. H., Robinson, A. E., McGill, J. W., Reardon, R. F., & Prekker, M. E. (2017) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2017.04.033 · Cited by 92
Self-citationUse of gum elastic bougie for prehospital difficult intubation
Jabre, P., Combes, X., Roux, B. L., Aaron, E., Auger, H., Margenet, A., & Dhonneur, G. (2005) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2004.12.005 · Cited by 91
Airway management outside the operating room: hazardous and incompletely studied
Cook, T. M., Behringer, E. C., & Benger, J. R. (2012) · Current Opinion in Anaesthesiology · doi:10.1097/aco.0b013e32835528b1 · Cited by 62
Bougie‐related airway trauma: dangers of the hold‐up sign
Marson, B. A., Anderson, E., Wilkes, A. R., & Hodzovic, I. (2014) · Anaesthesia · doi:10.1111/anae.12534 · Cited by 62
Intubation Bougie Dissection of Tracheal Mucosa and Intratracheal Airway Obstruction
Arndt, G. A., Cambray, A. J., & Tomasson, J. (2008) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e318176fe36 · Cited by 48
Joshi, R., Hypes, C. D., Greenberg, J., Snyder, L. S., Malo, J., Bloom, J. W., Chopra, H., Sakles, J. C., & Mosier, J. M. (2017) · Annals of the American Thoracic Society · doi:10.1513/annalsats.201606-472oc · Cited by 47
The humble bougie…forty years and still counting?
R., M. (2014) · Anaesthesia · doi:10.1111/anae.12600 · Cited by 44
Cited by
Apfelbaum, J. L., Hagberg, C. A., Connis, R. T., Abdelmalak, B. B., Agarkar, M., Dutton, R. P., Fiadjoe, J. E., Greif, R., Klock, P. A., Mercier, D., et al. (2022) · Anesthesiology · doi:10.1097/aln.0000000000004002 · Cited by 1,340
Apfelbaum, J. L., Hagberg, C. A., Connis, R. T., Abdelmalak, B., Agarkar, M., Dutton, R. P., Fiadjoe, J. E., Greif, R. T., Klock, P. A., Mercier, D. W., et al. (2022) · doi:10.48350/161339 · Cited by 526
The Italian coronavirus disease 2019 outbreak: recommendations from clinical practice
Sorbello, M., El‐Boghdadly, K., Di Giacinto, I., Cataldo, R., Esposito, C., Falcetta, S., Merli, G., Cortese, G., Corso, R. M., Bressan, F., et al. (2020) · Anaesthesia · doi:10.1111/anae.15049 · Cited by 346
Metadata
- Authors
- Driver, B. E., Prekker, M. E., Klein, L. R., Reardon, R. F., Miner, J. R., Fagerstrom, E. T., Cleghorn, M. R., McGill, J. W., & Cole, J. B.
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 2018-06-05
- Volume
- 319
- Issue
- 21
- Pages
- 2179
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W2803538670
- Cited by
- 313
- References
- 23
- FWCI
- 43.30
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.