The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
How to Read Articles That Use Machine Learning: Users’ Guides to the Medical Literature
Abstract
In recent years, many new clinical diagnostic tools have been developed using complicated machine learning methods. Irrespective of how a diagnostic tool is derived, it must be evaluated using a 3-step process of deriving, validating, and establishing the clinical effectiveness of the tool. Machine learning-based tools should also be assessed for the type of machine learning model used and its appropriateness for the input data type and data set size. Machine learning models also generally have additional prespecified settings called hyperparameters, which must be tuned on a data set independent of the validation set. On the validation set, the outcome against which the model is evaluated is termed the reference standard. The rigor of the reference standard must be assessed, such as against a universally accepted gold standard or expert grading.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“By contrast, data-driven methods have the potential to augment our capabilities in extracting patterns and relationships without squandering the potential of data fusion166–170.”
From End-to-end design of wearable sensors (2022) · cites this paper as [169]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
ImageNet Large Scale Visual Recognition Challenge
Russakovsky, O., Deng, J., Su, H., Krause, J., Satheesh, S., Ma, S., Huang, Z., Karpathy, A., Khosla, A., Bernstein, M., et al. (2015) · International Journal of Computer Vision · doi:10.1007/s11263-015-0816-y · Cited by 39,380
Self-citationThe meaning and use of the area under a receiver operating characteristic (ROC) curve.
Hanley, J. A., & McNeil, B. J. (1982) · Radiology · doi:10.1148/radiology.143.1.7063747 · Cited by 21,856
Gulshan, V., Peng, L., Coram, M., Stumpe, M. C., Wu, D., Narayanaswamy, A., Venugopalan, S., Widner, K., Madams, T., Cuadros, J., et al. (2016) · JAMA · doi:10.1001/jama.2016.17216 · Cited by 7,697
Self-citationMoons, K. G. M., Altman, D. G., Reitsma, J. B., Ioannidis, J. P. A., Macaskill, P., Steyerberg, E. W., Vickers, A. J., Ransohoff, D. F., & Collins, G. S. (2015) · Annals of Internal Medicine · doi:10.7326/m14-0698 · Cited by 5,147
Relaxing the Rule of Ten Events per Variable in Logistic and Cox Regression
Vittinghoff, E., & McCulloch, C. E. (2007) · American Journal of Epidemiology · doi:10.1093/aje/kwk052 · Cited by 4,359
Ehteshami Bejnordi, B., Veta, M., Johannes van Diest, P., van Ginneken, B., Karssemeijer, N., Litjens, G., van der Laak, J. A. W. M., and the CAMELYON16 Consortium, Hermsen, M., Manson, Q. F., et al. (2017) · JAMA · doi:10.1001/jama.2017.14585 · Cited by 3,293
Collins, G. S., Reitsma, J. B., Altman, D. G., & Moons, K. G. M. (2015) · Annals of Internal Medicine · doi:10.7326/m14-0697 · Cited by 3,267
Antman, E. M., Cohen, M., Bernink, P. J. L. M., McCabe, C. H., Horacek, T., Papuchis, G., Mautner, B., Corbalan, R., Radley, D., & Braunwald, E. (2000) · JAMA · doi:10.1001/jama.284.7.835 · Cited by 3,242
Understanding deep learning requires rethinking generalization
Zhang, C., Bengio, S., Hardt, M., Recht, B., & Vinyals, O. (2016) · arXiv · doi:10.48550/arxiv.1611.03530 · Cited by 2,838
Big Data and Machine Learning in Health Care
Beam, A. L., & Kohane, I. S. (2018) · JAMA · doi:10.1001/jama.2017.18391 · Cited by 2,506
Ting, D. S. W., Cheung, C. Y.-L., Lim, G., Tan, G. S. W., Quang, N. D., Gan, A., Hamzah, H., Garcia-Franco, R., San Yeo, I. Y., Lee, S. Y., et al. (2017) · JAMA · doi:10.1001/jama.2017.18152 · Cited by 2,402
Prediction of cardiovascular risk factors from retinal fundus photographs via deep learning
Poplin, R., Varadarajan, A. V., Blumer, K., Liu, Y., McConnell, M. V., Corrado, G. S., Peng, L., & Webster, D. R. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0195-0 · Cited by 1,865
Self-citationAlba, A. C., Agoritsas, T., Walsh, M., Hanna, S., Iorio, A., Devereaux, P. J., McGinn, T., & Guyatt, G. (2017) · JAMA · doi:10.1001/jama.2017.12126 · Cited by 1,631
Deep learning as a tool for increased accuracy and efficiency of histopathological diagnosis
Litjens, G., Sánchez, C. I., Timofeeva, N., Hermsen, M., Nagtegaal, I., Kovacs, I., Hulsbergen - van de Kaa, C., Bult, P., van Ginneken, B., & van der Laak, J. (2016) · Scientific Reports · doi:10.1038/srep26286 · Cited by 1,069
Jaeschke, R. (1994) · JAMA · doi:10.1001/jama.1994.03510290071040 · Cited by 1,049
Users' Guides to the Medical Literature: XXII: How to Use Articles About Clinical Decision Rules
McGinn, T. G., Guyatt, G. H., Wyer, P. C., Naylor, C. D., Stiell, I. G., Richardson, W. S., & for the Evidence-Based Medicine Working Group (2000) · JAMA · doi:10.1001/jama.284.1.79 · Cited by 1,014
A study to develop clinical decision rules for the use of radiography in acute ankle injuries
Stiell, I. G., Greenberg, G. H., McKnight, R. D., Nair, R. C., McDowell, I., & Worthington, J. R. (1992) · Annals of Emergency Medicine · doi:10.1016/s0196-0644(05)82656-3 · Cited by 676
Deep Learning—A Technology With the Potential to Transform Health Care
Hinton, G. (2018) · JAMA · doi:10.1001/jama.2018.11100 · Cited by 667
Krause, J., Gulshan, V., Rahimy, E., Karth, P., Widner, K., Corrado, G. S., Peng, L., & Webster, D. R. (2018) · Ophthalmology · doi:10.1016/j.ophtha.2018.01.034 · Cited by 564
Self-citationSteiner, D. F., MacDonald, R., Liu, Y., Truszkowski, P., Hipp, J. D., Gammage, C., Thng, F., Peng, L., & Stumpe, M. C. (2018) · American Journal of Surgical Pathology · doi:10.1097/pas.0000000000001151 · Cited by 489
Self-citationAdvances in Neural Information Processing Systems 26 (NIPS 2013)
Cseke, B., Opper, M., & Sanguinetti, G. (2013) · Cited by 424
Sayres, R., Taly, A., Rahimy, E., Blumer, K., Coz, D., Hammel, N., Krause, J., Narayanaswamy, A., Rastegar, Z., Wu, D., et al. (2019) · Ophthalmology · doi:10.1016/j.ophtha.2018.11.016 · Cited by 418
Self-citationCHAN, H.-P., DOI, K., VYBRONY, C. J., SCHMIDT, R. A., METZ, C. E., LAM, K. L., OGURA, T., WU, Y., & MACMAHON, H. (1990) · Investigative Radiology · doi:10.1097/00004424-199010000-00006 · Cited by 359
Multicentre trial to introduce the Ottawa ankle rules for use of radiography in acute ankle injuries
Stiell, I., Wells, G., Laupacis, A., Brison, R., Verbeek, R., Vandemheen, K., & Naylor, C. D. (1995) · BMJ · doi:10.1136/bmj.311.7005.594 · Cited by 299
Ruamviboonsuk, P., Krause, J., Chotcomwongse, P., Sayres, R., Raman, R., Widner, K., Campana, B. J. L., Phene, S., Hemarat, K., Tadarati, M., et al. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0099-8 · Cited by 233
Self-citationEvaluation of Artificial Intelligence–Based Grading of Diabetic Retinopathy in Primary Care
Kanagasingam, Y., Xiao, D., Vignarajan, J., Preetham, A., Tay-Kearney, M.-L., & Mehrotra, A. (2018) · JAMA Network Open · doi:10.1001/jamanetworkopen.2018.2665 · Cited by 185
Implementation of the Ottawa Ankle Rules in France
Auleley, G.-R. (1997) · JAMA · doi:10.1001/jama.1997.03540480035035 · Cited by 116
Evaluation of Automated Teleretinal Screening Program for Diabetic Retinopathy
Walton, O. B., Garoon, R. B., Weng, C. Y., Gross, J. B., Young, A. K., Camero, K. A., Jin, H. D., Carvounis, P. E., Coffee, R. E., & Chu, Y. I. (2015) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2015.5083 · Cited by 111
Sensitivity of the Ottawa Rules
Lucchesi, G. M., Jackson, R. E., Peacock, W. F., Cerasani, C., & Swor, R. A. (1995) · Annals of Emergency Medicine · doi:10.1016/s0196-0644(95)70229-6 · Cited by 82
Lung Nodule CAD Software as a Second Reader
WHITE, C. S., Pugatch, R. D., Koonce, T., Rust, S. W., & Dharaiya, E. (2008) · Academic Radiology · doi:10.1016/j.acra.2007.09.027 · Cited by 72
Halligan, S., Mallett, S., Altman, D. G., McQuillan, J., Proud, M., Beddoe, G., Honeyfield, L., & Taylor, S. A. (2010) · Radiology · doi:10.1148/radiol.10100354 · Cited by 69
Auleley, G.-R., Kerboull, L., Durieux, P., Cosquer, M., Courpied, J.-P., & Ravaud, P. (1998) · Annals of Emergency Medicine · doi:10.1016/s0196-0644(98)70093-9 · Cited by 63
Failed validation of a clinical decision rule for the use of radiography in acute ankle injury.
Kelly, A., Richards, D., Kerr, L. A., Grant, J., O'Donovan, P., Basire, K., & Graham, R. (1994) · PubMed · Cited by 58
Eyeing cardiovascular risk factors
Ting, D. S. W., & Wong, T. Y. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0210-5 · Cited by 45
Cited by
Heidenreich, P. A., Bozkurt, B., Aguilar, D., Allen, L. A., Byun, J. J., Colvin, M. M., Deswal, A., Drazner, M. H., Dunlay, S. M., Evers, L. R., et al. (2022) · Circulation · doi:10.1161/cir.0000000000001063 · Cited by 4,922
Revolutionizing healthcare: the role of artificial intelligence in clinical practice
Alowais, S. A., Alghamdi, S. S., Alsuhebany, N., Alqahtani, T., Alshaya, A. I., Almohareb, S. N., Aldairem, A., Alrashed, M., Bin Saleh, K., Badreldin, H. A., et al. (2023) · BMC Medical Education · doi:10.1186/s12909-023-04698-z · Cited by 3,146
2022 AHA/ACC/HFSA Guideline for the Management of Heart Failure
Heidenreich, P. A., Bozkurt, B., Aguilar, D., Allen, L. A., Byun, J. J., Colvin, M. M., Deswal, A., Drazner, M. H., Dunlay, S. M., Evers, L. R., et al. (2022) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2021.12.012 · Cited by 2,862
End-to-end design of wearable sensors
Ates, H. C., Nguyen, P. Q., Gonzalez-Macia, L., Morales-Narváez, E., Güder, F., Collins, J. J., & Dincer, C. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00460-x · Cited by 1,306
Collins, G. S., Dhiman, P., Andaur Navarro, C. L., Ma, J., Hooft, L., Reitsma, J. B., Logullo, P., Beam, A. L., Peng, L., Van Calster, B., et al. (2021) · BMJ Open · doi:10.1136/bmjopen-2020-048008 · Cited by 852
Self-citation
Metadata
- Authors
- Liu, Y., Chen, P.-H. C., Krause, J., & Peng, L.
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 2019-11-12
- Volume
- 322
- Issue
- 18
- Pages
- 1806
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W2988716771
- Cited by
- 516
- References
- 36
- FWCI
- 15.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.