Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 383

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Association of Use of an Intravascular Microaxial Left Ventricular Assist Device vs Intra-aortic Balloon Pump With In-Hospital Mortality and Major Bleeding Among Patients With Acute Myocardial Infarction Complicated by Cardiogenic Shock

Open access
Dhruva, Sanket S., Ross, Joseph S., Mortazavi, Bobak J., Hurley, Nathan C., Krumholz, Harlan M., Curtis, Jeptha P., Berkowitz, Alyssa, Masoudi, Frederick A., Messenger, John C., Parzynski, Craig S., Ngufor, Che, Girotra, Saket, Amin, Amit P., Shah, Nilay D., Desai, Nihar R.·2020·JAMA

Abstract

Importance: Acute myocardial infarction (AMI) complicated by cardiogenic shock is associated with substantial morbidity and mortality. Although intravascular microaxial left ventricular assist devices (LVADs) provide greater hemodynamic support as compared with intra-aortic balloon pumps (IABPs), little is known about clinical outcomes associated with intravascular microaxial LVAD use in clinical practice. Objective: To examine outcomes among patients undergoing percutaneous coronary intervention (PCI) for AMI complicated by cardiogenic shock treated with mechanical circulatory support (MCS) devices. Design, Setting, and Participants: A propensity-matched registry-based retrospective cohort study of patients with AMI complicated by cardiogenic shock undergoing PCI between October 1, 2015, and December 31, 2017, who were included in data from hospitals participating in the CathPCI and the Chest Pain-MI registries, both part of the American College of Cardiology's National Cardiovascular Data Registry. Patients receiving an intravascular microaxial LVAD were matched with those receiving IABP on demographics, clinical history, presentation, infarct location, coronary anatomy, and clinical laboratory data, with final follow-up through December 31, 2017. Exposures: Hemodynamic support, categorized as intravascular microaxial LVAD use only, IABP only, other (such as use of a percutaneous extracorporeal ventricular assist system, extracorporeal membrane oxygenation, or a combination of MCS device use), or medical therapy only. Main Outcomes and Measures: The primary outcomes were in-hospital mortality and in-hospital major bleeding. Results: Among 28 304 patients undergoing PCI for AMI complicated by cardiogenic shock, the mean (SD) age was 65.0 (12.6) years, 67.0% were men, 81.3% had an ST-elevation myocardial infarction, and 43.3% had cardiac arrest. Over the study period among patients with AMI, an intravascular microaxial LVAD was used in 6.2% of patients, and IABP was used in 29.9%. Among 1680 propensity-matched pairs, there was a significantly higher risk of in-hospital death associated with use of an intravascular microaxial LVAD (45.0%) vs with an IABP (34.1% [absolute risk difference, 10.9 percentage points {95% CI, 7.6-14.2}; P < .001) and also higher risk of in-hospital major bleeding (intravascular microaxial LVAD [31.3%] vs IABP [16.0%]; absolute risk difference, 15.4 percentage points [95% CI, 12.5-18.2]; P < .001). These associations were consistent regardless of whether patients received a device before or after initiation of PCI. Conclusions and Relevance: Among patients undergoing PCI for AMI complicated by cardiogenic shock from 2015 to 2017, use of an intravascular microaxial LVAD compared with IABP was associated with higher adjusted risk of in-hospital death and major bleeding complications, although study interpretation is limited by the observational design. Further research may be needed to understand optimal device choice for these patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jama.2020.0254

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 22 references

Cited by

See all 383

Metadata

Authors
Dhruva, S. S., Ross, J. S., Mortazavi, B. J., Hurley, N. C., Krumholz, H. M., Curtis, J. P., Berkowitz, A., Masoudi, F. A., Messenger, J. C., Parzynski, C. S., Ngufor, C., Girotra, S., Amin, A. P., Shah, N. D., & Desai, N. R.
Venue
JAMA
Published
2020-02-25
Volume
323
Issue
8
Pages
734
ISSN
  • 0002-9955 (ISSN-L)
  • 0098-7484
OpenAlex
W3005459416
Cited by
383
References
22
FWCI
19.68
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Association of Use of an Intravascular Microaxial Left Ventricular Assist Device vs Intra-aortic Balloon Pump With In-Hospital Mortality and Major Bleeding Among Patients With Acute Myocardial Infarction Complicated by Cardiogenic Shock. https://app.cochat.ai/papers/10.1001/jama.2020.0254
The paper
Dhruva, S. S., Ross, J. S., Mortazavi, B. J., Hurley, N. C., Krumholz, H. M., Curtis, J. P., Berkowitz, A., Masoudi, F. A., Messenger, J. C., Parzynski, C. S., Ngufor, C., Girotra, S., Amin, A. P., Shah, N. D., & Desai, N. R. (2020). Association of Use of an Intravascular Microaxial Left Ventricular Assist Device vs Intra-aortic Balloon Pump With In-Hospital Mortality and Major Bleeding Among Patients With Acute Myocardial Infarction Complicated by Cardiogenic Shock. JAMA. https://doi.org/10.1001/jama.2020.0254

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.