CoChat

Effect of Implantable vs Prolonged External Electrocardiographic Monitoring on Atrial Fibrillation Detection in Patients With Ischemic Stroke: The PER DIEM Randomized Clinical Trial

Open access
Buck, Brian H., Hill, Michael D., Quinn, F. Russell, Butcher, Ken S., Menon, Bijoy K., Gulamhusein, Sajad, Siddiqui, Muzaffar, Coutts, Shelagh B., Jeerakathil, Thomas, Smith, Eric E., Khan, Khurshid, Barber, Phillip A., Jickling, Glen, Reyes, Lucy, Save, Supriya, Fairall, Paige, Piquette, Lori, Kamal, Noreen, Chew, Derek S., Demchuk, Andrew M., Shuaib, Ashfaq, Exner, Derek V. · 2021 · JAMA
Cited by 179

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Importance: The relative rates of detection of atrial fibrillation (AF) or atrial flutter from evaluating patients with prolonged electrocardiographic monitoring with an external loop recorder or implantable loop recorder after an ischemic stroke are unknown. Objective: To determine, in patients with a recent ischemic stroke, whether 12 months of implantable loop recorder monitoring detects more occurrences of AF compared with conventional external loop recorder monitoring for 30 days. Design, Setting, and Participants: Investigator-initiated, open-label, randomized clinical trial conducted at 2 university hospitals and 1 community hospital in Alberta, Canada, including 300 patients within 6 months of ischemic stroke and without known AF from May 2015 through November 2017; final follow-up was in December 2018. Interventions: Participants were randomly assigned 1:1 to prolonged electrocardiographic monitoring with either an implantable loop recorder (n = 150) or an external loop recorder (n = 150) with follow-up visits at 30 days, 6 months, and 12 months. Main Outcomes and Measures: The primary outcome was the development of definite AF or highly probable AF (adjudicated new AF lasting ≥2 minutes within 12 months of randomization). There were 8 prespecified secondary outcomes including time to event analysis of new AF, recurrent ischemic stroke, intracerebral hemorrhage, death, and device-related serious adverse events within 12 months. Results: Among the 300 patients who were randomized (median age, 64.1 years [interquartile range, 56.1 to 73.7 years]; 121 were women [40.3%]; and 66.3% had a stroke of undetermined etiology with a median CHA2DS2-VASc [congestive heart failure, hypertension, age ≥75 years, diabetes, stroke or transient ischemic attack, vascular disease, age 65 to 74 years, sex category] score of 4 [interquartile range, 3 to 5]), 273 (91.0%) completed cardiac monitoring lasting 24 hours or longer and 259 (86.3%) completed both the assigned monitoring and 12-month follow-up visit. The primary outcome was observed in 15.3% (23/150) of patients in the implantable loop recorder group and 4.7% (7/150) of patients in the external loop recorder group (between-group difference, 10.7% [95% CI, 4.0% to 17.3%]; risk ratio, 3.29 [95% CI, 1.45 to 7.42]; P = .003). Of the 8 specified secondary outcomes, 6 were not significantly different. There were 5 patients (3.3%) in the implantable loop recorder group who had recurrent ischemic stroke vs 8 patients (5.3%) in the external loop recorder group (between-group difference, -2.0% [95% CI, -6.6% to 2.6%]), 1 (0.7%) vs 1 (0.7%), respectively, who had intracerebral hemorrhage (between-group difference, 0% [95% CI, -1.8% to 1.8%]), 3 (2.0%) vs 3 (2.0%) who died (between-group difference, 0% [95% CI, -3.2% to 3.2%]), and 1 (0.7%) vs 0 (0%) who had device-related serious adverse events. Conclusions and Relevance: Among patients with ischemic stroke and no prior evidence of AF, implantable electrocardiographic monitoring for 12 months, compared with prolonged external monitoring for 30 days, resulted in a significantly greater proportion of patients with AF detected over 12 months. Further research is needed to compare clinical outcomes associated with these monitoring strategies and relative cost-effectiveness. Trial Registration: ClinicalTrials.gov Identifier: NCT02428140.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jama.2021.6128

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 179

Metadata

Authors
Buck, B. H., Hill, M. D., Quinn, F. R., Butcher, K. S., Menon, B. K., Gulamhusein, S., Siddiqui, M., Coutts, S. B., Jeerakathil, T., Smith, E. E., Khan, K., Barber, P. A., Jickling, G., Reyes, L., Save, S., Fairall, P., Piquette, L., Kamal, N., Chew, D. S., Demchuk, A. M., Shuaib, A., & Exner, D. V.
Venue
JAMA
Published
2021-06-01
Volume
325
Issue
21
Pages
2160
ISSN
  • 0002-9955 (ISSN-L)
  • 0098-7484
OpenAlex
W3164950860
Cited by
179
References
8
FWCI
19.40
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effect of Implantable vs Prolonged External Electrocardiographic Monitoring on Atrial Fibrillation Detection in Patients With Ischemic Stroke: The PER DIEM Randomized Clinical Trial. https://app.cochat.ai/papers/10.1001/jama.2021.6128
The paper
Buck, B. H., Hill, M. D., Quinn, F. R., Butcher, K. S., Menon, B. K., Gulamhusein, S., Siddiqui, M., Coutts, S. B., Jeerakathil, T., Smith, E. E., Khan, K., Barber, P. A., Jickling, G., Reyes, L., Save, S., Fairall, P., Piquette, L., Kamal, N., Chew, D. S., . . . Exner, D. V. (2021). Effect of Implantable vs Prolonged External Electrocardiographic Monitoring on Atrial Fibrillation Detection in Patients With Ischemic Stroke: The PER DIEM Randomized Clinical Trial. JAMA. https://doi.org/10.1001/jama.2021.6128

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.