Value of the ventilation/perfusion scan in acute pulmonary embolism. Results of the prospective investigation of pulmonary embolism diagnosis (PIOPED). The PIOPED Investigators
The DOI matches its OpenAlex record.
Abstract
To determine the sensitivities and specificities of ventilation/perfusion lung scans for acute pulmonary embolism, a random sample of 933 of 1493 patients was studied prospectively. Nine hundred thirty-one underwent scintigraphy and 755 underwent pulmonary angiography; 251 (33%) of 755 demonstrated pulmonary embolism. Almost all patients with pulmonary embolism had abnormal scans of high, intermediate, or low probability, but so did most without pulmonary embolism (sensitivity, 98%; specificity, 10%). Of 116 patients with high-probability scans and definitive angiograms, 102 (88%) had pulmonary embolism, but only a minority with pulmonary embolism had high-probability scans (sensitivity, 41%; specificity, 97%). Of 322 with intermediate-probability scans and definitive angiograms, 105 (33%) had pulmonary embolism. Follow-up and angiography together suggest pulmonary embolism occurred among 12% of patients with low-probability scans. Clinical assessment combined with the ventilation/perfusion scan established the diagnosis or exclusion of pulmonary embolism only for a minority of patients—those with clear and concordant clinical and ventilation/perfusion scan findings. (JAMA. 1990;263:2753-2759)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Decousus, H., Leizorovicz, A., Parent, F., Page, Y., Tardy, B., Girard, P., Laporte, S., Faivre, R., Charbonnier, B., Barral, F.-G., et al. (1998) · New England Journal of Medicine · doi:10.1056/nejm199802123380701 · Cited by 1,702
Multidetector Computed Tomography for Acute Pulmonary Embolism
Stein, P. D., Fowler, S. E., Goodman, L. R., Gottschalk, A., Hales, C. A., Hull, R. D., Leeper, K. V., Popovich, J., Quinn, D. A., Sos, T. A., et al. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa052367 · Cited by 1,660
Samama, M. M., Cohen, A. T., Darmon, J.-Y., Desjardins, L., Eldor, A., Janbon, C., Leizorovicz, A., Nguyen, H., Olsson, C.-G., Turpie, A. G., et al. (1999) · New England Journal of Medicine · doi:10.1056/nejm199909093411103 · Cited by 1,584
Evaluation of D-Dimer in the Diagnosis of Suspected Deep-Vein Thrombosis
Wells, P. S., Anderson, D. R., Rodger, M., Forgie, M., Kearon, C., Dreyer, J., Kovacs, G., Mitchell, M., Lewandowski, B., & Kovacs, M. J. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa023153 · Cited by 1,552
A Prospective Study of Venous Thromboembolism after Major Trauma
Geerts, W. H., Code, K. I., Jay, R. M., Chen, E., & Szalai, J. P. (1994) · New England Journal of Medicine · doi:10.1056/nejm199412153312401 · Cited by 1,428
Koopman, M. M. W., Prandoni, P., Piovella, F., Ockelford, P. A., Brandjes, D. P. M., van der Meer, J., Gallus, A. S., Simonneau, G., Chesterman, C. H., Prins, M. H., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199603143341102 · Cited by 1,111
The Clinical Course of Pulmonary Embolism
Carson, J. L., Kelley, M. A., Duff, A., Weg, J. G., Fulkerson, W. J., Palevsky, H. I., Schwartz, J. S., Thompson, B. T., Popovich, J., Hobbins, T. E., et al. (1992) · New England Journal of Medicine · doi:10.1056/nejm199205073261902 · Cited by 1,039
Tapson, V. F. (2008) · New England Journal of Medicine · doi:10.1056/nejmra072753 · Cited by 1,024
Electronic Alerts to Prevent Venous Thromboembolism among Hospitalized Patients
Kucher, N., Koo, S., Quiroz, R., Cooper, J. M., Paterno, M. D., Soukonnikov, B., & Goldhaber, S. Z. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa041533 · Cited by 942
Goldhaber, S. Z., Come, P. C., Lee, R. T., Braunwald, E., Parker, J. A., Haire, W. D., Feldstein, M. L., Miller, M., Toltzis, R., Smith, J. L., et al. (1993) · The Lancet · doi:10.1016/0140-6736(93)90274-k · Cited by 849
Simonneau, G., Sors, H., Charbonnier, B., Page, Y., Laaban, J.-P., Azarian, R., Laurent, M., Hirsch, J.-L., Ferrari, E., Bosson, J.-L., et al. (1997) · New England Journal of Medicine · doi:10.1056/nejm199709043371002 · Cited by 782
High plasma levels of factor VIII and the risk of recurrent venous thromboembolism
Kyrle, P. A., Minar, E., Hirschl, M., Bialonczyk, C., Stain, M., Schneider, B., Weltermann, A., Speiser, W., Lechner, K., & Eichinger, S. (2000) · New England Journal of Medicine · doi:10.1056/nejm200008173430702 · Cited by 763
Hull, R. D., Raskob, G. E., Pineo, G. F., Green, D., Trowbridge, A. A., Elliott, C. G., Lerner, R. G., Hall, J., Sparling, T., Brettell, H. R., et al. (1992) · New England Journal of Medicine · doi:10.1056/nejm199204093261502 · Cited by 700
Bauer, K. A., Eriksson, B. I., Lassen, M. R., & Turpie, A. G. G. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa011099 · Cited by 666
Multidetector-Row Computed Tomography in Suspected Pulmonary Embolism
Perrier, A., Roy, P.-M., Sanchez, O., Le Gal, G., Meyer, G., Gourdier, A.-L., Furber, A., Revel, M.-P., Howarth, N., Davido, A., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa042905 · Cited by 642
Eriksson, B. I., Bauer, K. A., Lassen, M. R., & Turpie, A. G. G. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa011100 · Cited by 631
Sanchez, O., Trinquart, L., Colombet, I., Durieux, P., Huisman, M. V., Chatellier, G., & Meyer, G. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn208 · Cited by 552
Diagnosis of Pulmonary Embolism with Magnetic Resonance Angiography
Meaney, J. F. M., Weg, J. G., Chenevert, T. L., Stafford-Johnson, D., Hamilton, B. H., & Prince, M. R. (1997) · New England Journal of Medicine · doi:10.1056/nejm199705153362004 · Cited by 482
The Risk of Recurrent Venous Thromboembolism in Men and Women
Kyrle, P. A., Minar, E., Bialonczyk, C., Hirschl, M., Weltermann, A., & Eichinger, S. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032959 · Cited by 477
Goldhaber, S. Z. (1998) · New England Journal of Medicine · doi:10.1056/nejm199807093390207 · Cited by 428
Venous Thromboembolism during Pregnancy
Toglia, M. R., & Weg, J. G. (1996) · New England Journal of Medicine · doi:10.1056/nejm199607113350207 · Cited by 387
The Evaluation of Suspected Pulmonary Embolism
Fedullo, P. F., & Tapson, V. F. (2003) · New England Journal of Medicine · doi:10.1056/nejmcp035442 · Cited by 371
Management of Venous Thromboembolism
Ginsberg, J. S. (1996) · New England Journal of Medicine · doi:10.1056/nejm199612123352407 · Cited by 352
Inflammatory Bowel Disease Is a Risk Factor for Recurrent Venous Thromboembolism
Novacek, G., Weltermann, A., Sobala, A., Tilg, H., Petritsch, W., Reinisch, W., Mayer, A., Haas, T., Kaser, A., Feichtenschlager, T., et al. (2010) · Gastroenterology · doi:10.1053/j.gastro.2010.05.026 · Cited by 263
Lassen, M. R., Borris, L. C., & Nakov, R. L. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa011327 · Cited by 201
Reduced Dose Bolus Alteplase vs Conventional Alteplase Infusion for Pulmonary Embolism Thrombolysis
Goldhaber, S. Z., Agnelli, G., & Levine, M. N. (1994) · Chest · doi:10.1378/chest.106.3.718 · Cited by 193
Metadata
- Venue
- JAMA
- Publisher
- American Medical Association
- Published
- 1990-05-23
- Volume
- 263
- Issue
- 20
- Pages
- 2753-2759
- ISSN
- 0002-9955 (ISSN-L)
- OpenAlex
- W4233876362
- Cited by
- 376
- References
- 0
- FWCI
- 4.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.