Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 210

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Influence of Airway Management on Ventilator-Associated Pneumonia: Evidence From Randomized Trials

Cook, Deborah, De Jonghe, Bernard, Brochard, Laurent, Brun-Buisson, Christian·1998·JAMA

Abstract

OBJECTIVE: Ventilator-associated pneumonia (VAP) is a serious complication of critical illness, conferring increased morbidity and mortality. Many interventions have been studied to reduce the risk of VAP. We systematically reviewed the influence of airway management on VAP in critically ill patients. DATA SOURCES: Studies were identified through searching MEDLINE and EMBASE from 1980 through July 1997 and by searching SCISEARCH, the Cochrane Library, bibliographies of primary and review articles, personal files, and contact with authors of the randomized trials. STUDY SELECTION: We selected randomized trials evaluating ventilator circuit and secretion management strategies on the rate of VAP. DATA EXTRACTION: Two investigators independently abstracted key data on design features, the population, intervention, and outcome of the studies. DATA SYNTHESIS: The frequency of ventilator circuit changes and the type of endotracheal suction system do not appear to influence VAP rates (3 trials, none with significant difference; range of relative risks [RRs], 0.84-0.91). However, lower VAP rates may be associated with avoidance of heated humidifiers and use of heat and moisture exchangers (5 trials, only 1 showing a significant difference; range of RRs, 0.34-0.86), use of oral vs nasal intubation (1 trial; RR, 0.52; 95% confidence interval, 0.24-1.13), subglottic secretion drainage vs standard endotracheal tubes (2 trials, 1 showing a significant difference; range of RRs, 0.46-0.57), and kinetic vs conventional beds (5 trials, only 1 showing a significant difference; range of RRs, 0.35-0.78). CONCLUSIONS: Some ventilator circuit and secretion management strategies may influence VAP rates in critically ill patients. Whether these strategies are adopted in practice depends on several factors such as the magnitude and precision of estimates of benefit and harm, as well as access, availability, and costs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jama.279.10.781

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 210

Metadata

Authors
Cook, D., De Jonghe, B., Brochard, L., & Brun-Buisson, C.
Venue
JAMA
Published
1998-03-11
Volume
279
Issue
10
Pages
781
ISSN
  • 0002-9955 (ISSN-L)
  • 0098-7484
OpenAlex
W2080398666
Cited by
210
References
2
FWCI
10.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Influence of Airway Management on Ventilator-Associated Pneumonia: Evidence From Randomized Trials. https://app.cochat.ai/papers/10.1001/jama.279.10.781
The paper
Cook, D., De Jonghe, B., Brochard, L., & Brun-Buisson, C. (1998). Influence of Airway Management on Ventilator-Associated Pneumonia: Evidence From Randomized Trials. JAMA. https://doi.org/10.1001/jama.279.10.781

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.