Influence of Airway Management on Ventilator-Associated Pneumonia: Evidence From Randomized Trials
The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Ventilator-associated pneumonia (VAP) is a serious complication of critical illness, conferring increased morbidity and mortality. Many interventions have been studied to reduce the risk of VAP. We systematically reviewed the influence of airway management on VAP in critically ill patients. DATA SOURCES: Studies were identified through searching MEDLINE and EMBASE from 1980 through July 1997 and by searching SCISEARCH, the Cochrane Library, bibliographies of primary and review articles, personal files, and contact with authors of the randomized trials. STUDY SELECTION: We selected randomized trials evaluating ventilator circuit and secretion management strategies on the rate of VAP. DATA EXTRACTION: Two investigators independently abstracted key data on design features, the population, intervention, and outcome of the studies. DATA SYNTHESIS: The frequency of ventilator circuit changes and the type of endotracheal suction system do not appear to influence VAP rates (3 trials, none with significant difference; range of relative risks [RRs], 0.84-0.91). However, lower VAP rates may be associated with avoidance of heated humidifiers and use of heat and moisture exchangers (5 trials, only 1 showing a significant difference; range of RRs, 0.34-0.86), use of oral vs nasal intubation (1 trial; RR, 0.52; 95% confidence interval, 0.24-1.13), subglottic secretion drainage vs standard endotracheal tubes (2 trials, 1 showing a significant difference; range of RRs, 0.46-0.57), and kinetic vs conventional beds (5 trials, only 1 showing a significant difference; range of RRs, 0.35-0.78). CONCLUSIONS: Some ventilator circuit and secretion management strategies may influence VAP rates in critically ill patients. Whether these strategies are adopted in practice depends on several factors such as the magnitude and precision of estimates of benefit and harm, as well as access, availability, and costs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Systematic Reviews: Synthesis of Best Evidence for Clinical Decisions
Cook, D. J., Mulrow, C. D., & Haynes, R. B. (1997) · Annals of Internal Medicine · doi:10.7326/0003-4819-126-5-199703010-00006 · Cited by 2,184
Self-citationAn Assessment of Clinically Useful Measures of the Consequences of Treatment
Laupacis, A., Sackett, D. L., & Roberts, R. S. (1988) · New England Journal of Medicine · doi:10.1056/nejm198806303182605 · Cited by 1,681
Vincent, J.-L. (1995) · JAMA · doi:10.1001/jama.1995.03530080055041 · Cited by 1,632
KUDSK, K. A., CROCE, M. A., FABIAN, T. C., MINARD, G., TOLLEY, E. A., PORET, H. A., KUHL, M. R., & BROWN, R. O. (1992) · Annals of Surgery · doi:10.1097/00000658-199205000-00013 · Cited by 1,152
(1996) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.153.5.8630626 · Cited by 830
TEN versus TPN following Major Abdominal Trauma—Reduced Septic Morbidity
MOORE, F. A., MOORE, E. E., JONES, T. N., McCROSKEY, B. L., & PETERSON, V. M. (1989) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/00005373-198907000-00003 · Cited by 819
Ventilator-associated pneumonia. A multivariate analysis
Kollef, M. H. (1993) · JAMA · doi:10.1001/jama.270.16.1965 · Cited by 739
Torres, A., Serra-Batlles, J., Ros, E., Piera, C., de la Bellacasa, J. P., Cobos, A., Lomeña, F., & Rodríguez-Roisin, R. (1992) · Annals of Internal Medicine · doi:10.7326/0003-4819-116-7-540 · Cited by 721
Stress Ulcer Prophylaxis in Critically III Patients: Resolving Discordant Meta-analyses
Cook, D. J. (1996) · JAMA · doi:10.1001/jama.1996.03530280060038 · Cited by 608
Self-citationContinuous Aspiration of Subglottic Secretions in Preventing Ventilator-Associated Pneumonia
Valles, J., Artigas, A., Rello, J., Bonsoms, N., Fontanals, D., Blanch, L., Fernandez, R., Baigorri, F., & Mestre, J. (1995) · Annals of Internal Medicine · doi:10.7326/0003-4819-122-3-199502010-00004 · Cited by 549
Cited by
(2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200405-644st · Cited by 5,877
Systematic Reviews: Synthesis of Best Evidence for Clinical Decisions
Cook, D. J., Mulrow, C. D., & Haynes, R. B. (1997) · Annals of Internal Medicine · doi:10.7326/0003-4819-126-5-199703010-00006 · Cited by 2,184
Self-citationIncidence of and Risk Factors for Ventilator-Associated Pneumonia in Critically Ill Patients
Cook, D. J., Walter, S. D., Cook, R. J., Griffith, L. E., Guyatt, G. H., Leasa, D., Jaeschke, R. Z., & Brun-Buisson, C. (1998) · Annals of Internal Medicine · doi:10.7326/0003-4819-129-6-199809150-00002 · Cited by 1,113
Self-citationClinical and economic consequences of ventilator-associated pneumonia: A systematic review
Safdar, N., Dezfulian, C., Collard, H. R., & Saint, S. (2005) · Critical Care Medicine · doi:10.1097/01.ccm.0000181731.53912.d9 · Cited by 1,086
Terragni, P. P., Antonelli, M., Fumagalli, R., Faggiano, C., Berardino, M., Pallavicini, F. B., Miletto, A., Mangione, S., Sinardi, A. U., Pastorelli, M., et al. (2010) · JAMA · doi:10.1001/jama.2010.447 · Cited by 540
Ventilator-Associated Pneumonia
(2012) · SpringerReference · doi:10.1007/springerreference_225126 · Cited by 406
Eggimann, P., & Pittet, D. (2001) · Chest · doi:10.1378/chest.120.6.2059 · Cited by 395
Members of the Task Force:, Bouza, E., Brun-Buisson, C., Chastre, J., Ewig, S., Fagon, J.-Y., Marquette, C. H., Muñoz, P., Niederman, M. S., Papazian, L., et al. (2001) · European Respiratory Journal · doi:10.1183/09031936.01.17510340 · Cited by 335
Self-citationPrevention of Ventilator-Associated Pneumonia: An Evidence-Based Systematic Review
Collard, H. R., Saint, S., & Matthay, M. A. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-6-200303180-00015 · Cited by 304
Defining, treating and preventing hospital acquired pneumonia: European perspective
Torres, A., Ewig, S., Lode, H., Carlet, J., & For The European HAP working group (2009) · Intensive Care Medicine · doi:10.1007/s00134-008-1336-9 · Cited by 298
Rotstein, C., Evans, G., Born, A., Grossman, R., Light, R. B., Magder, S., McTaggart, B., Weiss, K., & Zhanel, G. G. (2008) · Canadian Journal of Infectious Diseases and Medical Microbiology · doi:10.1155/2008/593289 · Cited by 282
Risk Factors for Ventilator‐Associated Pneumonia: From Epidemiology to Patient Management
Bonten, M. J. M., Kollef, M. H., & Hall, J. B. (2004) · Clinical Infectious Diseases · doi:10.1086/383039 · Cited by 238
“A large number of prospective, randomized trials have shown that the frequency of ventilator circuit change does not affect the incidence of VAP [76, 77].”
BackgroundKearns, P. J., Chin, D., Mueller, L., Wallace, K., Jensen, W. A., & Kirsch, C. M. (2000) · Critical Care Medicine · doi:10.1097/00003246-200006000-00007 · Cited by 223
Qualitative review of intensive care unit quality indicators
Berenholtz, S. M., Dorman, T., Ngo, K., & Pronovost, P. J. (2002) · Journal of Critical Care · doi:10.1053/jcrc.2002.33035 · Cited by 221
Rello, J., Lorente, C., Bodí, M., Diaz, E., Ricart, M., & Kollef, M. H. (2002) · Chest · doi:10.1378/chest.122.2.656 · Cited by 208
Risk Factors for ICU-Acquired Pneumonia
Cook, D. J. (1998) · JAMA · doi:10.1001/jama.279.20.1605 · Cited by 190
Self-citationFISCHER, S., MACLEAN, A. A., LIU, M., CARDELLA, J. A., SLUTSKY, A. S., SUGA, M., MOREIRA, J. F. M., & KESHAVJEE, S. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.5.9910064 · Cited by 185
“Consequently, patients are subjected to prolonged intubation, ventilator-associated infections, longer stays in the intensive care unit (ICU), and early postoperative mortality (6, 7 ).”
BackgroundKogo, M., Nagata, K., Morimoto, T., Ito, J., Sato, Y., Teraoka, S., Fujimoto, D., Nakagawa, A., Otsuka, K., & Tomii, K. (2017) · Respiratory Care · doi:10.4187/respcare.05003 · Cited by 69
Metadata
- Authors
- Cook, D., De Jonghe, B., Brochard, L., & Brun-Buisson, C.
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 1998-03-11
- Volume
- 279
- Issue
- 10
- Pages
- 781
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W2080398666
- Cited by
- 210
- References
- 40
- FWCI
- 10.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.