Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 393

The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.

Accuracy of Hysteroscopy in the Diagnosis of Endometrial Cancer and Hyperplasia: A Systematic Quantitative Review

Clark, T. Justin, Voit, Doris, Gupta, Janesh K., Hyde, Christopher, Song, Fujian, Khan, Khalid S. · 2002 · JAMA

Abstract

CONTEXT: Hysteroscopy (direct endoscopic visualization of the endometrial cavity) is used extensively in the evaluation of common gynecologic problems, such as menorrhagia and postmenopausal bleeding. However, there is a continuing debate about the value of this technology in the diagnosis of serious endometrial disease. OBJECTIVE: To determine the accuracy of hysteroscopy in diagnosing endometrial cancer and hyperplasia in women with abnormal uterine bleeding. DATA SOURCES: Relevant articles were identified through searches of the Cochrane Library, MEDLINE, and EMBASE (1984-2001), manual searches of bibliographies of known primary and review articles, and contact with manufacturers. STUDY SELECTION: Studies were selected blindly, independently, and in duplicate if accuracy of hysteroscopy was estimated in women with abnormal uterine bleeding, using histopathologic findings as a reference standard. Our search identified 3486 articles; 208 of these were deemed to be potentially eligible and were retrieved for detailed data extraction. Sixty-five primary studies were analyzed, including 26 346 women. DATA EXTRACTION: Data were abstracted on characteristics and quality from each study. Results for diagnostic accuracy were extracted to form 2 x 2 contingency tables separately for endometrial cancer and endometrial disease (cancer, hyperplasia, or both). Pooled likelihood ratios (LRs) were used as summary accuracy measures. DATA SYNTHESIS: The pretest probability of endometrial cancer was 3.9% (95% confidence interval [CI], 3.7%-4.2%). A positive hysteroscopy result (pooled LR, 60.9; 95% CI, 51.2-72.5) increased the probability of cancer to 71.8% (95% CI, 67.0%-76.6%), whereas a negative hysteroscopy result (pooled LR, 0.15; 95% CI, 0.13-0.18) reduced the probability of cancer to 0.6% (95% CI, 0.5%-0.8%). There was statistical heterogeneity in pooling of LRs, but an explanation for this could not be found in spectrum composition and study quality. The overall accuracy for the diagnosis of endometrial disease was modest compared with that of cancer, and the results were heterogeneous. The accuracy tended to be higher among postmenopausal women and in the outpatient setting. CONCLUSION: The diagnostic accuracy of hysteroscopy is high for endometrial cancer, but only moderate for endometrial disease (cancer or hyperplasia).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jama.288.13.1610

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 38 references

Cited by

See all 393

Metadata

Authors
Clark, T. J., Voit, D., Gupta, J. K., Hyde, C., Song, F., & Khan, K. S.
Venue
JAMA
Published
2002-10-02
Volume
288
Issue
13
Pages
1610
ISSN
  • 0002-9955 (ISSN-L)
  • 0098-7484
OpenAlex
W2145117334
Cited by
393
References
38
FWCI
13.92
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accuracy of Hysteroscopy in the Diagnosis of Endometrial Cancer and Hyperplasia: A Systematic Quantitative Review. https://app.cochat.ai/papers/10.1001/jama.288.13.1610
The paper
Clark, T. J., Voit, D., Gupta, J. K., Hyde, C., Song, F., & Khan, K. S. (2002). Accuracy of Hysteroscopy in the Diagnosis of Endometrial Cancer and Hyperplasia: A Systematic Quantitative Review. JAMA. https://doi.org/10.1001/jama.288.13.1610

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.