The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Monitoring Sedation Status Over Time in ICU Patients: Reliability and Validity of the Richmond Agitation-Sedation Scale (RASS)
Abstract
CONTEXT: Goal-directed delivery of sedative and analgesic medications is recommended as standard care in intensive care units (ICUs) because of the impact these medications have on ventilator weaning and ICU length of stay, but few of the available sedation scales have been appropriately tested for reliability and validity. OBJECTIVE: To test the reliability and validity of the Richmond Agitation-Sedation Scale (RASS). DESIGN: Prospective cohort study. SETTING: Adult medical and coronary ICUs of a university-based medical center. PARTICIPANTS: Thirty-eight medical ICU patients enrolled for reliability testing (46% receiving mechanical ventilation) from July 21, 1999, to September 7, 1999, and an independent cohort of 275 patients receiving mechanical ventilation were enrolled for validity testing from February 1, 2000, to May 3, 2001. MAIN OUTCOME MEASURES: Interrater reliability of the RASS, Glasgow Coma Scale (GCS), and Ramsay Scale (RS); validity of the RASS correlated with reference standard ratings, assessments of content of consciousness, GCS scores, doses of sedatives and analgesics, and bispectral electroencephalography. RESULTS: In 290-paired observations by nurses, results of both the RASS and RS demonstrated excellent interrater reliability (weighted kappa, 0.91 and 0.94, respectively), which were both superior to the GCS (weighted kappa, 0.64; P<.001 for both comparisons). Criterion validity was tested in 411-paired observations in the first 96 patients of the validation cohort, in whom the RASS showed significant differences between levels of consciousness (P<.001 for all) and correctly identified fluctuations within patients over time (P<.001). In addition, 5 methods were used to test the construct validity of the RASS, including correlation with an attention screening examination (r = 0.78, P<.001), GCS scores (r = 0.91, P<.001), quantity of different psychoactive medication dosages 8 hours prior to assessment (eg, lorazepam: r = - 0.31, P<.001), successful extubation (P =.07), and bispectral electroencephalography (r = 0.63, P<.001). Face validity was demonstrated via a survey of 26 critical care nurses, which the results showed that 92% agreed or strongly agreed with the RASS scoring scheme, and 81% agreed or strongly agreed that the instrument provided a consensus for goal-directed delivery of medications. CONCLUSIONS: The RASS demonstrated excellent interrater reliability and criterion, construct, and face validity. This is the first sedation scale to be validated for its ability to detect changes in sedation status over consecutive days of ICU care, against constructs of level of consciousness and delirium, and correlated with the administered dose of sedative and analgesic medications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Statistical Methods for Rates and Proportions
Fleiss, J. L., Levin, B., & Paik, M. C. (2003) · Wiley Series in Probability and Statistics · doi:10.1002/0471445428 · Cited by 18,646
ASSESSMENT OF COMA AND IMPAIRED CONSCIOUSNESS
Teasdale, G., & Jennett, B. (1974) · The Lancet · doi:10.1016/s0140-6736(74)91639-0 · Cited by 13,215
Sessler, C. N., Gosnell, M. S., Grap, M. J., Brophy, G. M., O'Neal, P. V., Keane, K. A., Tesoro, E. P., & Elswick, R. K. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.2107138 · Cited by 3,695
Self-citationEly, E. W., Inouye, S. K., Bernard, G. R., Gordon, S., Francis, J., May, L., Truman, B., Speroff, T., Gautam, S., Margolin, R., et al. (2001) · JAMA · doi:10.1001/jama.286.21.2703 · Cited by 3,210
Self-citationIntensive Care Delirium Screening Checklist: evaluation of a new screening tool
Bergeron, N., Dubois, M.-J., Dumont, M., Dial, S., & Skrobik, Y. (2001) · Intensive Care Medicine · doi:10.1007/s001340100909 · Cited by 1,487
Prospective evaluation of the Sedation-Agitation Scale for adult critically ill patients
Riker, R. R., Picard, J. T., & Fraser, G. L. (1999) · Critical Care Medicine · doi:10.1097/00003246-199907000-00022 · Cited by 961
Delirium in an intensive care unit: a study of risk factors
Dubois, M.-J., Bergeron, N., Dumont, M., Dial, S., & Skrobik, Y. (2001) · Intensive Care Medicine · doi:10.1007/s001340101017 · Cited by 609 · cited 1×
“Only recently has the ICU community begun to focus on delirium as an essential element of patient comfort and outcome.(8,50,51) Importantly, a key feature of delirium is the presence or absence of inattention, which can be measured in part by the ability of a person to maintain eye contact.”
Background
Cited by
Schweickert, W. D., Pohlman, M. C., Pohlman, A. S., Nigos, C., Pawlik, A. J., Esbrook, C. L., Spears, L., Miller, M., Franczyk, M., Deprizio, D., et al. (2009) · The Lancet · doi:10.1016/s0140-6736(09)60658-9 · Cited by 3,339
Delirium as a Predictor of Mortality in Mechanically Ventilated Patients in the Intensive Care Unit
Ely, E. W. (2004) · JAMA · doi:10.1001/jama.291.14.1753 · Cited by 3,073
Self-citationIncidence, risk factors and consequences of ICU delirium
Ouimet, S., Kavanagh, B. P., Gottfried, S. B., & Skrobik, Y. (2007) · Intensive Care Medicine · doi:10.1007/s00134-006-0399-8 · Cited by 972
Bellelli, G., Morandi, A., Davis, D. H. J., Mazzola, P., Turco, R., Gentile, S., Ryan, T., Cash, H., Guerini, F., Torpilliesi, T., et al. (2014) · Age and Ageing · doi:10.1093/ageing/afu021 · Cited by 788
Delirium and its motoric subtypes: A study of 614 critically ill patients
Peterson, J. F., Pun, B. T., Dittus, R. S., Thomason, J. W. W., Jackson, J. C., Shintani, A. K., & Ely, E. W. (2006) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.2005.00621.x · Cited by 660
Metadata
- Authors
- Ely, E. W., Truman, B., Shintani, A., Thomason, J. W. W., Wheeler, A. P., Gordon, S., Francis, J., Speroff, T., Gautam, S., Margolin, R., Sessler, C. N., Dittus, R. S., & Bernard, G. R.
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 2003-06-11
- Volume
- 289
- Issue
- 22
- Pages
- 2983
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W2099066338
- Cited by
- 1,707
- References
- 7
- FWCI
- 23.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Monitoring Sedation Status Over Time in ICU Patients: Reliability and Validity of the Richmond Agitation-Sedation Scale (RASS). https://app.cochat.ai/papers/10.1001/jama.289.22.2983
- The paper
- Ely, E. W., Truman, B., Shintani, A., Thomason, J. W. W., Wheeler, A. P., Gordon, S., Francis, J., Speroff, T., Gautam, S., Margolin, R., Sessler, C. N., Dittus, R. S., & Bernard, G. R. (2003). Monitoring Sedation Status Over Time in ICU Patients: Reliability and Validity of the Richmond Agitation-Sedation Scale (RASS). JAMA. https://doi.org/10.1001/jama.289.22.2983
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.