Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 367

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Detection of Bladder Cancer Using a Point-of-Care Proteomic Assay

Grossman, H. Barton·2005·JAMA

Abstract

CONTEXT: A combination of methods is used for diagnosis of bladder cancer because no single procedure detects all malignancies. Urine tests are frequently part of an evaluation, but have either been nonspecific for cancer or required specialized analysis at a laboratory. OBJECTIVE: To investigate whether a point-of-care proteomic test that measures the nuclear matrix protein NMP22 in voided urine could enhance detection of malignancy in patients with risk factors or symptoms of bladder cancer. DESIGN, SETTING, AND PATIENTS: Twenty-three academic, private practice, and veterans' facilities in 10 states prospectively enrolled consecutive patients from September 2001 to May 2002. Participants included 1331 patients at elevated risk for bladder cancer due to factors such as history of smoking or symptoms including hematuria and dysuria. Patients at risk for malignancy of the urinary tract provided a voided urine sample for analysis of NMP22 protein and cytology prior to cystoscopy. MAIN OUTCOME MEASURES: The diagnosis of bladder cancer, based on cystoscopy with biopsy, was accepted as the reference standard. The performance of the NMP22 test was compared with voided urine cytology as an aid to cancer detection. Testing for the NMP22 tumor marker was conducted in a blinded manner. RESULTS: Bladder cancer was diagnosed in 79 patients. The NMP22 assay was positive in 44 of 79 patients with cancer (sensitivity, 55.7%; 95% confidence interval [CI], 44.1%-66.7%), whereas cytology test results were positive in 12 of 76 patients (sensitivity, 15.8%; 95% CI, 7.6%-24.0%). The specificity of the NMP22 assay was 85.7% (95% CI, 83.8%-87.6%) compared with 99.2% (95% CI, 98.7%-99.7%) for cytology. The proteomic marker detected 4 cancers that were not visualized during initial endoscopy, including 3 that were muscle invasive and 1 carcinoma in situ. CONCLUSION: The noninvasive point-of-care assay for elevated urinary NMP22 protein can increase the accuracy of cystoscopy, with test results available during the patient visit.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jama.293.7.810

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 15 references

Cited by

See all 367

Metadata

Authors
Grossman, H. B.
Venue
JAMA
Published
2005-02-16
Volume
293
Issue
7
Pages
810
ISSN
  • 0002-9955 (ISSN-L)
  • 0098-7484
OpenAlex
W2130116769
Cited by
367
References
15
FWCI
28.24
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Detection of Bladder Cancer Using a Point-of-Care Proteomic Assay. https://app.cochat.ai/papers/10.1001/jama.293.7.810
The paper
Grossman, H. B. (2005). Detection of Bladder Cancer Using a Point-of-Care Proteomic Assay. JAMA. https://doi.org/10.1001/jama.293.7.810

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.