CoChat

Management of Recalled Pacemakers and Implantable Cardioverter-Defibrillators: A Decision Analysis Model

Amin, Mitesh S., Matchar, David B., Wood, Mark A., Ellenbogen, Kenneth A. · 2006 · JAMA
Cited by 61

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

CONTEXT: Limited information exists to direct clinical management after an implantable device has been put under advisory. A better understanding of the risks and benefits of device replacement compared with continued clinical follow-up would be helpful to clinicians. OBJECTIVE: Using the tools of decision analysis, to determine the best management approach (immediate device replacement vs continued monitoring) in the setting of a device advisory. DESIGN: A decision model was constructed to evaluate the risks and benefits associated with immediate device replacement compared with continued monitoring. MAIN OUTCOME MEASURES: Variables considered included indications for device implantation, anticipated course following device failure, device failure rates from the advisory ranging from 0.0001% to 1.0% per year, and device replacement mortality rates ranging from 0.10% to 1.00% per procedure. Device replacement was preferred to continued follow-up when replacement led to greater patient survival. RESULTS: The decision to replace a recalled device depends primarily on the advisory's estimated device failure rate and the likely effects of device failure on mortality. Procedural mortality is an important secondary factor, while patient age and remaining generator life have the least influence on the decision. For pacemaker-dependent patients, advisory device failure rates exceeding 0.3% warrant device replacement in most situations. In patients with implantable cardioverter-defibrillators for primary or secondary prevention, a failure rate associated with an advisory of 3.0% is needed to favor replacement in most cases, decreasing to close to 1.0% as procedural mortality rates decrease to 0.1% or risk of fatal arrhythmias increase to near 20% per year. In cases of pacemaker implantation for non-life-threatening situations (eg, carotid sinus hypersensitivity), most device advisories do not warrant device replacement. CONCLUSIONS: The decision to replace a device under advisory is determined primarily by the incidence of device malfunction and the likely effects of device failure. This analysis provides a framework for managing recalled devices in the context of device, patient, and institutional characteristics.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jama.296.4.412

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Amin, M. S., Matchar, D. B., Wood, M. A., & Ellenbogen, K. A.
Venue
JAMA
Published
2006-07-26
Volume
296
Issue
4
Pages
412
ISSN
  • 0002-9955 (ISSN-L)
  • 0098-7484
OpenAlex
W2091470642
Cited by
61
References
3
FWCI
7.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.