Diagnosis of Myocardial Infarction Using a High-Sensitivity Troponin I 1-Hour Algorithm
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
IMPORTANCE: Rapid and accurate diagnosis of acute myocardial infarction (AMI) currently constitutes an unmet need. OBJECTIVE: To test a 1-hour diagnostic algorithm to diagnose AMI using a high-sensitivity troponin I assay with a new cutoff level of 6 ng/L. DESIGN, SETTING, AND PARTICIPANTS: The Biomarkers in Acute Cardiac Care study is a prospective study that investigated the application of the troponin I assay for the diagnosis of AMI in 1040 patients presenting to the emergency department with acute chest pain from July 19, 2013, to December 31, 2014. Results were validated in 2 independent cohorts of 4009 patients. Final follow-up was completed on July 1, 2015, and data were assessed from July 2 to December 15, 2015. EXPOSURE: Acute chest pain suggestive of AMI. MAIN OUTCOMES AND MEASURES: Accurate diagnosis or exclusion of AMI and 12-month mortality in patients with acute chest pain. RESULTS: Of the 1040 patients included from the study cohort, 673 (64.7%) were male and had a median age of 65 (interquartile range, 52-75) years. With application of a low troponin I cutoff value of 6 ng/L, the rule-out algorithm showed a high negative predictive value of 99.8% (95% CI, 98.6%-100.0%) after 1 hour for non-ST-segment elevation MI type 1. The 1-hour approach was comparable to a 3-hour approach. Similarly, a rule-in algorithm based on troponin I levels provided a high positive predictive value with 82.8% (95% CI, 73.2%-90.0%). Moreover, application of the cutoff of 6 ng/L resulted in lower follow-up mortality (1.0%) compared with the routinely used 99th percentile (3.7%) for this assay. Two independent cohorts further validated the performance of this algorithm with high negative and positive predictive values. CONCLUSIONS AND RELEVANCE: Patients with possible AMI can be triaged within 1 hour after admission with no loss of safety compared with a 3-hour approach, when a low and sensitive cutoff is applied. This concept enables safe discharge or rapid treatment initiation after 1 hour.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Modeling Survival Data: Extending the Cox Model
Therneau, T. M., & Grambsch, P. M. (2000) · Statistics for Biology and Health · doi:10.1007/978-1-4757-3294-8 · Cited by 8,674
Roffi, M., Patrono, C., Collet, J.-P., Mueller, C., Valgimigli, M., Andreotti, F., Bax, J. J., Borger, M. A., Brotons, C., Chew, D. P., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehv320 · Cited by 8,261
Self-citation
Cited by
2023 ESC Guidelines for the management of acute coronary syndromes
Byrne, R. A., Rossello, X., Coughlan, J. J., Barbato, E., Berry, C., Chieffo, A., Claeys, M. J., Dan, G.-A., Dweck, M. R., Galbraith, M., et al. (2023) · European Heart Journal · doi:10.1093/eurheartj/ehad191 · Cited by 5,333
Self-citationCollet, J.-P., Thiele, H., Barbato, E., Barthélémy, O., Bauersachs, J., Bhatt, D. L., Dendale, P., Dorobantu, M., Edvardsen, T., Folliguet, T., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehaa575 · Cited by 5,037
Self-citationShah, A. S. V., Anand, A., Strachan, F. E., Ferry, A. V., Lee, K. K., Chapman, A. R., Sandeman, D., Stables, C. L., Adamson, P. D., Andrews, J. P. M., et al. (2018) · The Lancet · doi:10.1016/s0140-6736(18)31923-8 · Cited by 388
Application of High-Sensitivity Troponin in Suspected Myocardial Infarction
Neumann, J. T., Twerenbold, R., Ojeda, F., Sörensen, N. A., Chapman, A. R., Shah, A. S. V., Anand, A., Boeddinghaus, J., Nestelberger, T., Badertscher, P., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1803377 · Cited by 346
Self-citationCardiac biomarkers of acute coronary syndrome: from history to high-sensitivity cardiac troponin
Garg, P., Morris, P., Fazlanie, A. L., Vijayan, S., Dancso, B., Dastidar, A. G., Plein, S., Mueller, C., & Haaf, P. (2017) · Internal and Emergency Medicine · doi:10.1007/s11739-017-1612-1 · Cited by 319
Self-citation
Metadata
- Authors
- Neumann, J. T., Sörensen, N. A., Schwemer, T., Ojeda, F., Bourry, R., Sciacca, V., Schaefer, S., Waldeyer, C., Sinning, C., Renné, T., Than, M., Parsonage, W., Wildi, K., Makarova, N., Schnabel, R. B., Landmesser, U., Mueller, C., Cullen, L., Greenslade, J., Zeller, T., Blankenberg, S., Karakas, M., & Westermann, D.
- Venue
- JAMA Cardiology
- Publisher
- American Medical Association (AMA)
- Published
- 2016-07-01
- Volume
- 1
- Issue
- 4
- Pages
- 397
- ISSN
- 2380-6583 (ISSN-L)
- OpenAlex
- W2418832234
- Cited by
- 228
- References
- 3
- FWCI
- 25.40
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diagnosis of Myocardial Infarction Using a High-Sensitivity Troponin I 1-Hour Algorithm. https://app.cochat.ai/papers/10.1001/jamacardio.2016.0695
- The paper
- Neumann, J. T., Sörensen, N. A., Schwemer, T., Ojeda, F., Bourry, R., Sciacca, V., Schaefer, S., Waldeyer, C., Sinning, C., Renné, T., Than, M., Parsonage, W., Wildi, K., Makarova, N., Schnabel, R. B., Landmesser, U., Mueller, C., Cullen, L., Greenslade, J., . . . Westermann, D. (2016). Diagnosis of Myocardial Infarction Using a High-Sensitivity Troponin I 1-Hour Algorithm. JAMA Cardiology. https://doi.org/10.1001/jamacardio.2016.0695
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.