One-Year Safety and Clinical Outcomes of a Transcatheter Interatrial Shunt Device for the Treatment of Heart Failure With Preserved Ejection Fraction in the Reduce Elevated Left Atrial Pressure in Patients With Heart Failure (REDUCE LAP-HF I) Trial: A Randomized Clinical Trial
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Importance: In patients with heart failure (HF) and left ventricular ejection fraction (LVEF) equal to or greater than 40%, a transcatheter interatrial shunt device (IASD; Corvia Medical) reduces exercise pulmonary capillary wedge pressure (PCWP) and is safe compared with sham control treatment at 1 month of follow-up. The longer-term safety and patency of the IASD has not yet been demonstrated in the setting of a randomized clinical trial (RCT). Objective: To evaluate the 1-year safety and clinical outcomes of the IASD compared with a sham control treatment. Design, Setting, and Participants: This phase 2, double-blind, 1-to-1 sham-controlled multicenter RCT of IASD implantation vs a sham procedure (femoral venous access and imaging of the interatrial septum without IASD) was conducted in 22 centers in the United States, Europe, and Australia on patients with New York Heart Association (NYHA) class III or ambulatory class IV HF, LVEF equal to or greater than 40%, exercise PCWP equal to or greater than 25 mm Hg, and PCWP-right atrial pressure gradient equal to or greater than 5 mm Hg. Main Outcomes and Measures: Safety was assessed by major adverse cardiac, cerebrovascular, or renal events (MACCRE). Exploratory outcomes evaluated at 1 year were hospitalizations for HF, NYHA class, quality of life, a 6-minute walk test, and device patency. Results: After 1 year, shunts were patent in all IASD-treated patients; MACCRE did not differ significantly in the IASD arm (2 of 21 [9.5%]) vs the control arm (5 of 22 [22.7%]; P = .41), and no strokes occurred. The yearly rate of hospitalizations for HF was 0.22 in the IASD arm and 0.63 in the control arm (P = .06). Median improvement in NYHA class was 1 class in the IASD arm (IQR, -1 to 0) vs 0 in the control arm (IQR, -1 to 0; P = .08). Quality of life and 6-minute walk test distance were similar in both groups. At 6 months, there was an increase in right ventricular size in the IASD arm (mean [SD], 7.9 [8.0] mL/m2) vs the control arm (-1.8 [9.6] mL/m2; P = .002), consistent with left-to-right shunting through the device; no further increase occurred in the IASD arm at 12 months. Conclusions and Relevance: The REDUCE LAP-HF I phase 2, sham-controlled RCT confirms the longer-term patency of the IASD. Through 1 year of follow-up, IASD treatment appears safe, with no significant differences in MACCRE in patients receiving IASD compared with those who received sham control treatment. Trial Registration: ClinicalTrials.gov identifier: NCT02600234.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
EuroQol: a new facility for the measurement of health-related quality of life
(1990) · Health Policy · doi:10.1016/0168-8510(90)90421-9 · Cited by 15,736
2016 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure
Ponikowski, P., Voors, A. A., Anker, S. D., Bueno, H., Cleland, J. G. F., Coats, A. J. S., Falk, V., González-Juanatey, J. R., Harjola, V.-P., Jankowska, E. A., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw128 · Cited by 11,429
Self-citationYancy, C. W., Jessup, M., Bozkurt, B., Butler, J., Casey, D. E., Colvin, M. M., Drazner, M. H., Filippatos, G. S., Fonarow, G. C., Givertz, M. M., et al. (2017) · Circulation · doi:10.1161/cir.0000000000000509 · Cited by 3,109
Phenotype-Specific Treatment of Heart Failure With Preserved Ejection Fraction: A Multiorgan Roadmap
Shah, S. J., Kitzman, D. W., Borlaug, B. A., van Heerebeek, L., Zile, M. R., Kass, D. A., & Paulus, W. J. (2016) · Circulation · doi:10.1161/circulationaha.116.021884 · Cited by 1,003
Self-citationThe pathophysiology of heart failure with preserved ejection fraction
Borlaug, B. A. (2014) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2014.83 · Cited by 726
MMRM vs. LOCF: A Comprehensive Comparison Based on Simulation Study and 25 NDA Datasets
Siddiqui, O., Hung, H. M. J., & O'Neill, R. (2009) · Journal of Biopharmaceutical Statistics · doi:10.1080/10543400802609797 · Cited by 301
Joseph, S. M., Novak, E., Arnold, S. V., Jones, P. G., Khattak, H., Platts, A. E., Dávila-Román, V. G., Mann, D. L., & Spertus, J. A. (2013) · Circulation: Heart Failure · doi:10.1161/circheartfailure.113.000359 · Cited by 192
Cited by
2021 ESC guidelines for the diagnosis and treatment of acute and chronic heart failure
McDonagh, T. A., Metra, M., Adamo, M., Gardner, R. S., Baumbach, A., Böhm, M., Burri, H., Butler, J., Čelutkienė, J., Chioncel, O., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab368 · Cited by 13,344
Self-citationAuthors/Task Force Members:, McDonagh, T. A., Metra, M., Adamo, M., Gardner, R. S., Baumbach, A., Böhm, M., Burri, H., Butler, J., Čelutkienė, J., et al. (2022) · European Journal of Heart Failure · doi:10.1002/ejhf.2333 · Cited by 2,171
Self-citationEvaluation and management of heart failure with preserved ejection fraction
Borlaug, B. A. (2020) · Nature Reviews Cardiology · doi:10.1038/s41569-020-0363-2 · Cited by 675
Kittleson, M. M., Panjrath, G. S., Amancherla, K., Davis, L. L., Deswal, A., Dixon, D. L., Januzzi, J. L., & Yancy, C. W. (2023) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2023.03.393 · Cited by 554
Shah, S. J., Borlaug, B. A., Chung, E. S., Cutlip, D. E., Debonnaire, P., Fail, P. S., Gao, Q., Hasenfuß, G., Kahwash, R., Kaye, D. M., et al. (2022) · The Lancet · doi:10.1016/s0140-6736(22)00016-2 · Cited by 249
Self-citation
Metadata
- Authors
- Shah, S. J., Feldman, T., Ricciardi, M. J., Kahwash, R., Lilly, S., Litwin, S., Nielsen, C. D., van der Harst, P., Hoendermis, E., Penicka, M., Bartunek, J., Fail, P. S., Kaye, D. M., Walton, A., Petrie, M. C., Walker, N., Basuray, A., Yakubov, S., Hummel, S. L., Chetcuti, S., Forde-McLean, R., Herrmann, H. C., Burkhoff, D., Massaro, J. M., Cleland, J. G. F., & Mauri, L.
- Venue
- JAMA Cardiology
- Publisher
- American Medical Association (AMA)
- Published
- 2018-10-01
- Volume
- 3
- Issue
- 10
- Pages
- 968
- ISSN
- 2380-6583 (ISSN-L)
- OpenAlex
- W2889412844
- Cited by
- 157
- References
- 7
- FWCI
- 12.04
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: One-Year Safety and Clinical Outcomes of a Transcatheter Interatrial Shunt Device for the Treatment of Heart Failure With Preserved Ejection Fraction in the Reduce Elevated Left Atrial Pressure in Patients With Heart Failure (REDUCE LAP-HF I) Trial: A Randomized Clinical Trial. https://app.cochat.ai/papers/10.1001/jamacardio.2018.2936
- The paper
- Shah, S. J., Feldman, T., Ricciardi, M. J., Kahwash, R., Lilly, S., Litwin, S., Nielsen, C. D., van der Harst, P., Hoendermis, E., Penicka, M., Bartunek, J., Fail, P. S., Kaye, D. M., Walton, A., Petrie, M. C., Walker, N., Basuray, A., Yakubov, S., Hummel, S. L., . . . Mauri, L. (2018). One-Year Safety and Clinical Outcomes of a Transcatheter Interatrial Shunt Device for the Treatment of Heart Failure With Preserved Ejection Fraction in the Reduce Elevated Left Atrial Pressure in Patients With Heart Failure (REDUCE LAP-HF I) Trial: A Randomized Clinical Trial. JAMA Cardiology. https://doi.org/10.1001/jamacardio.2018.2936
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.