CoChat

Device-Guided Breathing as Treatment for Hypertension in Type 2 Diabetes Mellitus: A Randomized, Double-blind, Sham-Controlled Trial

Open access
Landman, Gijs W. D., Drion, Iefke, van Hateren, Kornelis J. J., van Dijk, Peter R., Logtenberg, Susan J. J., Lambert, Jan, Groenier, Klaas H., Bilo, Henk J. G., Kleefstra, Nanne · 2013 · JAMA Internal Medicine
Cited by 40

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

IMPORTANCE: Biofeedback with device-guided lowering of breathing frequency could be an alternate nonpharmacologic treatment option for hypertension. Evidence from trials with high methodologic quality is lacking. OBJECTIVE: To evaluate the effects of device-guided lowering of breathing frequency on blood pressure in patients with type 2 diabetes mellitus and hypertension. DESIGN: Single-center, double-blind, sham-controlled trial. SETTING: A large nonacademic teaching hospital in the Netherlands. PARTICIPANTS: Patients with type 2 diabetes mellitus and hypertension. INTERVENTION: Fifteen-minute sessions with either the device that guides breathing through musical tones to a lower breathing frequency (aiming at <10 breaths/min) or a sham device (music without aiming at lowering of breathing frequency) for an 8-week study period. MAIN OUTCOMES AND MEASURES: Systolic and diastolic blood pressure measured in the physician's office. RESULTS: Forty-eight patients were randomized; 21 patients (88%) in the intervention group and 24 patients (100%) in the control group completed the study. There were no significant changes in systolic and diastolic blood pressure, with a difference in systolic blood pressure of 2.35 mm Hg (95% CI, -6.50 to 11.20) in favor of the control group and a difference in diastolic blood pressure of 2.25 mm Hg (95% CI, -2.16 to 6.67) in favor of the intervention group. Three patients in the intervention group experienced adverse events. CONCLUSIONS AND RELEVANCE: This high methodologic quality study shows no significant effect of device-guided lowering of breathing frequency on office-measured blood pressure in patients with type 2 diabetes. On the basis of this study, together with results from all but one previous trial, device-guided lowering of breathing frequency does not appear to be a viable nonpharmacologic option for hypertension treatment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jamainternmed.2013.6883

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 40

Metadata

Authors
Landman, G. W. D., Drion, I., van Hateren, K. J. J., van Dijk, P. R., Logtenberg, S. J. J., Lambert, J., Groenier, K. H., Bilo, H. J. G., & Kleefstra, N.
Venue
JAMA Internal Medicine
Published
2013-07-22
Volume
173
Issue
14
Pages
1346
ISSN
2168-6106 (ISSN-L)
OpenAlex
W2158212680
Cited by
40
References
1
FWCI
4.03
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Device-Guided Breathing as Treatment for Hypertension in Type 2 Diabetes Mellitus: A Randomized, Double-blind, Sham-Controlled Trial. https://app.cochat.ai/papers/10.1001/jamainternmed.2013.6883
The paper
Landman, G. W. D., Drion, I., van Hateren, K. J. J., van Dijk, P. R., Logtenberg, S. J. J., Lambert, J., Groenier, K. H., Bilo, H. J. G., & Kleefstra, N. (2013). Device-Guided Breathing as Treatment for Hypertension in Type 2 Diabetes Mellitus: A Randomized, Double-blind, Sham-Controlled Trial. JAMA Internal Medicine. https://doi.org/10.1001/jamainternmed.2013.6883

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.