CoChat

Device-Guided Breathing for Hypertension: a Summary Evidence Review

Mahtani, Kamal R., Beinortas, Tumas, Bauza, Karolis, Nunan, David · 2016 · Current Hypertension Reports

The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.

Abstract

Persistently raised blood pressure is one of the major risk factors for diseases such as myocardial infarction and stroke. Uncontrolled hypertension is also associated with high rates of mortality, particularly in middle and high-income countries. Lifestyle factors such as poor diet, obesity, physical inactivity and smoking are all thought to contribute to the development of hypertension. As a result, the management of hypertension should begin with modifying these lifestyle factors. Beyond this, drug interventions are used as the predominant form of management. However, adherence to medications can be highly variable, medication side effects are common, and may require regular monitoring or, in some individuals may be ineffective. Therefore, additional non-pharmacologic interventions that lower blood pressure may be advantageous when combined with lifestyle modifications. Such interventions may include relaxation therapies such as slow breathing exercises, which can be initiated by means of specific devices. The technique of device-guided breathing (DGB) has been considered by guideline developers in the management of hypertension. One specific device, the Resperate, has received US FDA and UK NHS approval over the last few years. In this review, we summarise the evidence base on efficacy and find that although some clinical trials exist that demonstrate a BP-lowering effect, others do not. There is currently insufficient evidence from pooled data to recommend the routine use of device-guided breathing in hypertensive patients.

Overview

Integrity signals

Registry

Crossref · 10.1007/s11906-016-0631-z

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 32 references

Research works printed but not linked: 1

  1. NICE, editor. Hypertension: the clinical management of primary hypertension in adults: update of clinical guidelines 18 and 34. London: Royal College of Physicians; 2011.

Cited by

See all 28

Metadata

Authors
Mahtani, K. R., Beinortas, T., Bauza, K., & Nunan, D.
Affiliations
  • University of Oxford (GB)
  • Vilnius University (LT)
Corresponding author
Mahtani, Kamal R.
Venue
Current Hypertension Reports
Published
2016-04
Volume
18
Issue
4
Pages
33-33
ISSN
  • 1522-6417 (ISSN-L)
  • 1534-3111
OpenAlex
W2318249401
Cited by
28
References
32
Citations by year
2025: 1 · 2024: 3 · 2023: 2 · 2022: 8 · 2021: 5 · 2020: 3 · 2019: 3 · 2017: 3
FWCI
0.35
Type
journal article
Language
en
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • Current Hypertension Reports (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Institute for Health and Care Research (CL-2011-13-006)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
Keywords
hypertension, lifestyle modification, medication adherence, blood pressure reduction, relaxation training
MeSH terms
Blood Pressure, Breathing Exercises, Humans, Hypertension, Respiration, Risk Factors

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Device-Guided Breathing for Hypertension: a Summary Evidence Review. https://app.cochat.ai/papers/10.1007/s11906-016-0631-z
The paper
Mahtani, K. R., Beinortas, T., Bauza, K., & Nunan, D. (2016). Device-Guided Breathing for Hypertension: a Summary Evidence Review. Current Hypertension Reports. https://doi.org/10.1007/s11906-016-0631-z

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.