The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Contamination of Health Care Personnel During Removal of Personal Protective Equipment
Open accessAbstract
IMPORTANCE: Contamination of the skin and clothing of health care personnel during removal of personal protective equipment (PPE) contributes to dissemination of pathogens and places personnel at risk for infection. OBJECTIVES: To determine the frequency and sites of contamination on the skin and clothing of personnel during PPE removal and to evaluate the effect of an intervention on the frequency of contamination. DESIGN, SETTING, AND PARTICIPANTS: We conducted a point-prevalence study and quasi-experimental intervention from October 28, 2014, through March 31, 2015. Data analysis began November 17, 2014, and ended April 21, 2015. Participants included a convenience sample of health care personnel from 4 Northeast Ohio hospitals who conducted simulations of contaminated PPE removal using fluorescent lotion and a cohort of health care personnel from 7 study units in 1 medical center that participated in a quasi-experimental intervention that included education and practice in removal of contaminated PPE with immediate visual feedback based on fluorescent lotion contamination of skin and clothing. MAIN OUTCOMES AND MEASURES: The primary outcomes were the frequency and sites of contamination on skin and clothing of personnel after removal of contaminated gloves or gowns at baseline vs after the intervention. A secondary end point focused on the correlation between contamination of skin with fluorescent lotion and bacteriophage MS2, a nonpathogenic, nonenveloped virus. RESULTS: Of 435 glove and gown removal simulations, contamination of skin or clothing with fluorescent lotion occurred in 200 (46.0%), with a similar frequency of contamination among the 4 hospitals (range, 42.5%-50.3%). Contamination occurred more frequently during removal of contaminated gloves than gowns (52.9% vs 37.8%, P = .002) and when lapses in technique were observed vs not observed (70.3% vs 30.0%, P < .001). The intervention resulted in a reduction in skin and clothing contamination during glove and gown removal (60.0% before the intervention vs 18.9% after, P < .001) that was sustained after 1 and 3 months (12.0% at both time points, P < .001 compared with before the intervention). During simulations of contaminated glove removal, the frequency of skin contamination was similar with fluorescent lotion and bacteriophage MS2 (58.0% vs 52.0%, P = .45). CONCLUSIONS AND RELEVANCE: Contamination of the skin and clothing of health care personnel occurs frequently during removal of contaminated gloves or gowns. Educational interventions that include practice with immediate visual feedback on skin and clothing contamination can significantly reduce the risk of contamination during removal of PPE.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Measurement of Observer Agreement for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529310 · Cited by 81,148
A Coefficient of Agreement for Nominal Scales
Cohen, J. (1960) · Educational and Psychological Measurement · doi:10.1177/001316446002000104 · Cited by 42,398
Siegel, J. D., Rhinehart, E., Jackson, M., & Chiarello, L. (2007) · American Journal of Infection Control · doi:10.1016/j.ajic.2007.10.007 · Cited by 3,456
2014 MERS-CoV Outbreak in Jeddah — A Link to Health Care Facilities
Oboho, I. K., Tomczyk, S. M., Al-Asmari, A. M., Banjar, A. A., Al-Mugti, H., Aloraini, M. S., Alkhaldi, K. Z., Almohammadi, E. L., Alraddadi, B. M., Gerber, S. I., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1408636 · Cited by 475
Siegel, J. D., & Rhinehart, E. (2007) · Medical Entomology and Zoology · Cited by 440
Hayden, M. K., Blom, D. W., Lyle, E. A., Moore, C. G., & Weinstein, R. A. (2008) · Infection Control & Hospital Epidemiology · doi:10.1086/524331 · Cited by 304
Morgan, D. J., Rogawski, E., Thom, K. A., Johnson, J. K., Perencevich, E. N., Shardell, M., Leekha, S., & Harris, A. D. (2012) · Critical Care Medicine · doi:10.1097/ccm.0b013e31823bc7c8 · Cited by 249
SARS Transmission among Hospital Workers in Hong Kong
Lau, J. T. F., Fung, K. S., Wong, T. W., Kim, J. H., Wong, E., Chung, S., Ho, D., Chan, L. Y., Lui, S. F., & Cheng, A. (2004) · Emerging Infectious Diseases · doi:10.3201/eid1002.030534 · Cited by 224
Morgan, D. J., Liang, S. Y., Smith, C. L., Johnson, J. K., Harris, A. D., Furuno, J. P., Thorn, K. A., Snyder, G. M., Day, H. R., & Perencevich, E. N. (2010) · Infection Control & Hospital Epidemiology · doi:10.1086/653201 · Cited by 204
Virus Transfer from Personal Protective Equipment to Healthcare Employees’ Skin and Clothing
Casanova, L., Alfano-Sobsey, E., Rutala, W. A., Weber, D. J., & Sobsey, M. (2008) · Emerging Infectious Diseases · doi:10.3201/eid1408.080085 · Cited by 194
Cited by
Stemming the Superbug Tide: Just A Few Dollars More
OECD (2018) · OECD Health Policy Studies · doi:10.1787/9789264307599-en · Cited by 748
Verbeek, J. H., Rajamaki, B., Ijaz, S., Sauni, R., Toomey, E., Blackwood, B., Tikka, C., Ruotsalainen, J. H., & Kilinc Balci, F. S. (2020) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011621.pub4 · Cited by 657
Managing ICU surge during the COVID-19 crisis: Rapid guidelines.
Aziz, S., Arabi, Y. M., Alhazzani, W., Evans, L., Citerio, G., Fischkoff, K., Salluh, J., Meyfroidt, G., Alshamsi, F., Oczkowski, S., et al. (2020) · Intensive Care Medicine · doi:10.1007/s00134-020-06092-5 · Cited by 380
Rehabilitation After Critical Illness in People With COVID-19 Infection
Simpson, R., & Robinson, L. (2020) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0000000000001443 · Cited by 318
Verbeek, J. H., Rajamaki, B., Ijaz, S., Tikka, C., Ruotsalainen, J. H., Edmond, M. B., Sauni, R., & Kilinc Balci, F. S. (2019) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011621.pub3 · Cited by 276
Metadata
- Authors
- Tomas, M. E., Kundrapu, S., Thota, P., Sunkesula, V. C. K., Cadnum, J. L., Mana, T. S. C., Jencson, A., O’Donnell, M., Zabarsky, T. F., Hecker, M. T., Ray, A. J., Wilson, B. M., & Donskey, C. J.
- Venue
- JAMA Internal Medicine
- Publisher
- American Medical Association (AMA)
- Published
- 2015-12-01
- Volume
- 175
- Issue
- 12
- Pages
- 1904
- ISSN
- 2168-6106 (ISSN-L)
- OpenAlex
- W2136570140
- Cited by
- 311
- References
- 24
- FWCI
- 15.90
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Contamination of Health Care Personnel During Removal of Personal Protective Equipment. https://app.cochat.ai/papers/10.1001/jamainternmed.2015.4535
- The paper
- Tomas, M. E., Kundrapu, S., Thota, P., Sunkesula, V. C. K., Cadnum, J. L., Mana, T. S. C., Jencson, A., O’Donnell, M., Zabarsky, T. F., Hecker, M. T., Ray, A. J., Wilson, B. M., & Donskey, C. J. (2015). Contamination of Health Care Personnel During Removal of Personal Protective Equipment. JAMA Internal Medicine. https://doi.org/10.1001/jamainternmed.2015.4535
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.