The DOI matches its Crossref record; 150 of the 150 references it cites were found in a registry or an index.
Personal protective equipment for preventing highly infectious diseases due to exposure to contaminated body fluids in healthcare staff
Open accessAbstract
BACKGROUND: In epidemics of highly infectious diseases, such as Ebola Virus Disease (EVD) or Severe Acute Respiratory Syndrome (SARS), healthcare workers (HCW) are at much greater risk of infection than the general population, due to their contact with patients' contaminated body fluids. Contact precautions by means of personal protective equipment (PPE) can reduce the risk. It is unclear which type of PPE protects best, what is the best way to remove PPE, and how to make sure HCW use PPE as instructed. OBJECTIVES: To evaluate which type of full body PPE and which method of donning or doffing PPE have the least risk of self-contamination or infection for HCW, and which training methods increase compliance with PPE protocols. SEARCH METHODS: We searched MEDLINE (PubMed up to 15 July 2018), Cochrane Central Register of Trials (CENTRAL up to 18 June 2019), Scopus (Scopus 18 June 2019), CINAHL (EBSCOhost 31 July 2018), and OSH-Update (up to 31 December 2018). We also screened reference lists of included trials and relevant reviews, and contacted NGOs and manufacturers of PPE. SELECTION CRITERIA: We included all controlled studies that compared the effects of PPE used by HCW exposed to highly infectious diseases with serious consequences, such as Ebola or SARS, on the risk of infection, contamination, or noncompliance with protocols. This included studies that used simulated contamination with fluorescent markers or a non-pathogenic virus.We also included studies that compared the effect of various ways of donning or doffing PPE, and the effects of training in PPE use on the same outcomes. DATA COLLECTION AND ANALYSIS: Two authors independently selected studies, extracted data and assessed risk of bias in included trials. We planned to perform meta-analyses but did not find sufficiently similar studies to combine their results. MAIN RESULTS: We included 17 studies with 1950 participants evaluating 21 interventions. Ten studies are Randomised Controlled Trials (RCTs), one is a quasi RCT and six have a non-randomised controlled design. Two studies are awaiting assessment.Ten studies compared types of PPE but only six of these reported sufficient data. Six studies compared different types of donning and doffing and three studies evaluated different types of training. Fifteen studies used simulated exposure with fluorescent markers or harmless viruses. In simulation studies, contamination rates varied from 10% to 100% of participants for all types of PPE. In one study HCW were exposed to Ebola and in another to SARS.Evidence for all outcomes is based on single studies and is very low quality.Different types of PPEPPE made of more breathable material may not lead to more contamination spots on the trunk (Mean Difference (MD) 1.60 (95% Confidence Interval (CI) -0.15 to 3.35) than more water repellent material but may have greater user satisfaction (MD -0.46; 95% CI -0.84 to -0.08, scale of 1 to 5).Gowns may protect better against contamination than aprons (MD large patches -1.36 95% CI -1.78 to -0.94).The use of a powered air-purifying respirator may protect better than a simple ensemble of PPE without such respirator (Relative Risk (RR) 0.27; 95% CI 0.17 to 0.43).Five different PPE ensembles (such as gown vs. coverall, boots with or without covers, hood vs. cap, length and number of gloves) were evaluated in one study, but there were no event data available for compared groups.Alterations to PPE design may lead to less contamination such as added tabs to grab masks (RR 0.33; 95% CI 0.14 to 0.80) or gloves (RR 0.22 95% CI 0.15 to 0.31), a sealed gown and glove combination (RR 0.27; 95% CI 0.09 to 0.78), or a better fitting gown around the neck, wrists and hands (RR 0.08; 95% CI 0.01 to 0.55) compared to standard PPE.Different methods of donning and doffing proceduresDouble gloving may lead to less contamination compared to single gloving (RR 0.36; 95% CI 0.16 to 0.78).Following CDC recommendations for doffing may lead to less contamination compared to no guidance (MD small patches -5.44; 95% CI -7.43 to -3.45).Alcohol-based hand rub used during the doffing process may not lead to less contamination than the use of a hypochlorite based solution (MD 4.00; 95% CI 0.47 to 34.24).Additional spoken instruction may lead to fewer errors in doffing (MD -0.9, 95% CI -1.4 to -0.4).Different types of trainingThe use of additional computer simulation may lead to fewer errors in doffing (MD -1.2, 95% CI -1.6 to -0.7).A video lecture on donning PPE may lead to better skills scores (MD 30.70; 95% CI 20.14,41.26) than a traditional lecture.Face to face instruction may reduce noncompliance with doffing guidance more (OR 0.45; 95% CI 0.21 to 0.98) than providing folders or videos only.There were no studies on effects of training in the long term or on resource use.The quality of the evidence is very low for all comparisons because of high risk of bias in all studies, indirectness of evidence, and small numbers of participants. AUTHORS'
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ROBINS-I: a tool for assessing risk of bias in non-randomised studies of interventions
Sterne, J. A., Hernán, M. A., Reeves, B. C., Savović, J., Berkman, N. D., Viswanathan, M., Henry, D., Altman, D. G., Ansari, M. T., Boutron, I., et al. (2016) · BMJ · doi:10.1136/bmj.i4919 · Cited by 20,329
Seto, W., Tsang, D., Yung, R., Ching, T., Ng, T., Ho, M., Ho, L., & Peiris, J. (2003) · The Lancet · doi:10.1016/s0140-6736(03)13168-6 · Cited by 863
Physical interventions to interrupt or reduce the spread of respiratory viruses
Jefferson, T., Del Mar, C. B., Dooley, L., Ferroni, E., Al-Ansary, L. A., Bawazeer, G. A., van Driel, M. L., Nair, N. S., Jones, M. A., Thorning, S., et al. (2011) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006207.pub4 · Cited by 805
Interventions to improve hand hygiene compliance in patient care
Gould, D. J., Moralejo, D., Drey, N., Chudleigh, J. H., & Taljaard, M. (2017) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd005186.pub4 · Cited by 663
Verbeek, J. H., Rajamaki, B., Ijaz, S., Sauni, R., Toomey, E., Blackwood, B., Tikka, C., Ruotsalainen, J. H., & Kilinc Balci, F. S. (2020) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011621.pub4 · Cited by 657
Self-citationMoon, S., Sridhar, D., Pate, M. A., Jha, A. K., Clinton, C., Delaunay, S., Edwin, V., Fallah, M., Fidler, D. P., Garrett, L., et al. (2015) · The Lancet · doi:10.1016/s0140-6736(15)00946-0 · Cited by 629
Physical interventions to interrupt or reduce the spread of respiratory viruses: systematic review
Jefferson, T., Del Mar, C., Dooley, L., Ferroni, E., Al-Ansary, L. A., Bawazeer, G. A., van Driel, M. L., Foxlee, R., & Rivetti, A. (2009) · BMJ · doi:10.1136/bmj.b3675 · Cited by 562
SARS among Critical Care Nurses, Toronto
Loeb, M., McGeer, A., Henry, B., Ofner, M., Rose, D., Hlywka, T., Levie, J., McQueen, J., Smith, S., Moss, L., et al. (2004) · Emerging Infectious Diseases · doi:10.3201/eid1002.030838 · Cited by 345
Adverse outcomes associated with contact precautions: A review of the literature
Morgan, D. J., Diekema, D. J., Sepkowitz, K., & Perencevich, E. N. (2009) · American Journal of Infection Control · doi:10.1016/j.ajic.2008.04.257 · Cited by 329
Contamination of Health Care Personnel During Removal of Personal Protective Equipment
Tomas, M. E., Kundrapu, S., Thota, P., Sunkesula, V. C. K., Cadnum, J. L., Mana, T. S. C., Jencson, A., O’Donnell, M., Zabarsky, T. F., Hecker, M. T., et al. (2015) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2015.4535 · Cited by 311
Research works printed but not linked: 32
- Casanova, Oct 2016, Assessment of self-contamination during removal of personal protective equipment for Ebola patient care, Infection Control and Hospital Epidemiology, 37, 1156, 10.1017/ice.2016.169 · doi:10.1017/ice.2016.169
- Curtis, Feb 2018, Video-based learning vs traditional lecture for instructing emergency medicine residents in disaster medicine principles of mass triage, decontamination, and personal protective equipment, Prehospital and Disaster Medicine, 33, 7, 10.1017/S1049023X1700718X · doi:10.1017/s1049023x1700718x
- Gleser, Mar 2018, Modified gloves: A chance for the prevention of nosocomial infections, American Journal of Infection Control, 46, 266, 10.1016/j.ajic.2017.08.024 · doi:10.1016/j.ajic.2017.08.024
- Mana, Jan 2018, A Randomized trial of two cover gowns comparing contamination of healthcare personnel during removal of personal protective equipment, Infection Control & Hospital Epidemiology, 39, 97, 10.1017/ice.2017.249 · doi:10.1017/ice.2017.249
- Tomas, Jun 2016, Seamless suits: reducing personnel contamination through improved personal protective equipment design, Infection Control & Hospital Epidemiology, 37, 742, 10.1017/ice.2016.79 · doi:10.1017/ice.2016.79
- Beam, 2016, Personal protective equipment processes and rationale for the Nebraska Biocontainment Unit during the 2014 activations for Ebola virus disease, American journal of infection control, 44, 340, 10.1016/j.ajic.2015.09.031 · doi:10.1016/j.ajic.2015.09.031
- Beam, 2016, Call for improvement in personal protective equipment guidance and research, American journal of infection control, 44, 1428, 10.1016/j.ajic.2016.05.040 · doi:10.1016/j.ajic.2016.05.040
- Biddell, 2016, Use of simulation to gauge preparedness for Ebola at a free-standing children's hospital, Simulation in Healthcare, 11, 94, 10.1097/SIH.0000000000000134 · doi:10.1097/sih.0000000000000134
- Bosc, 2016, Impact of the personal protective equipment for Ebola virus disease on vascular access skills and the performance of airway: A manikin study, Annales Francaises de Medecine d'Urgence, 6, 172, 10.1007/s13341-016-0631-2 · doi:10.1007/s13341-016-0631-2
- Butt, 2016, Infection control and prevention practices implemented to reduce transmission risk of Middle East respiratory syndrome-coronavirus in a tertiary care institution in Saudi Arabia, American Journal of Infection Control, 44, 605, 10.1016/j.ajic.2016.01.004 · doi:10.1016/j.ajic.2016.01.004
- Chu, 2017, Report from the world health organization's advisory committees on innovative personal protective equipment for front line health workers, American Journal of Tropical Medicine and Hygiene, 97, 283
- Doll, 2017, Acceptability and necessity of training for optimal personal protective equipment use, Infection Control and Hospital Epidemiology, 38, 226, 10.1017/ice.2016.252 · doi:10.1017/ice.2016.252
- Doshi, 2016, Seroprevalence of Ebola virus among health care workers in the Tshuapa district, Democratic Republic of the Congo, American Journal of Tropical Medicine and Hygiene, 95, 50
- Elcin, 2016, Developing a simulation-based training program for the prehospital professionals and students on the management of Middle East respiratory syndrome, Simulation in Healthcare, 11, 394, 10.1097/SIH.0000000000000198 · doi:10.1097/sih.0000000000000198
- Foote, 2017, Assessment of hospital emergency department response to potentially infectious diseases using unannounced mystery patient drills - New York city, 2016, MMWR. Morbidity and Mortality Weekly Report, 66, 945, 10.15585/mmwr.mm6636a2 · doi:10.15585/mmwr.mm6636a2
- Grélot, Moderate thermal strain in healthcare workers wearing personal protective equipment during treatment and care activities in the context of the 2014 Ebola virus disease outbreak, Journal of Infectious Diseases, 212, [Epub ahead of
- Herlihey, 2017, The impact of environmental design on doffing personal protective equipment in a healthcare environment: A formative human factors trial, Infection Control and Hospital Epidemiology, 38, 712, 10.1017/ice.2017.68 · doi:10.1017/ice.2017.68
- Kang, 2017, Difficulties in using personal protective equipment: Training experiences with the 2015 outbreak of Middle East respiratory syndrome in Korea, Antimicrobial Resistance and Infection Control, 6, 53
- Kilinc-Balci, 2015, Evaluation of the performance of isolation gowns, American Journal of Infection Control, 43, S44, 10.1016/j.ajic.2015.04.112 · doi:10.1016/j.ajic.2015.04.112
- Kratz, 2017, Discussion of two infection prevention and control training approaches to enhance biosafety in primary healthcare facilities during an outbreak of Ebola virus disease, Tropical Medicine and International Health, 22, 167
- Lee, 2017, Which personal protective equipment to provide? Challenges during the Ebola outbreak and lessons learned, Tropical Medicine and International Health, 22, 29
- McLaws, 2016, A highly precautionary doffing sequence for health care workers after caring for wet Ebola patients to further reduce occupational acquisition of Ebola, American journal of infection control, 44, 740, 10.1016/j.ajic.2015.12.034 · doi:10.1016/j.ajic.2015.12.034
- Nikiforuk, 2017, Challenge of liquid stressed protective materials and environmental persistence of Ebola virus, Scientific Reports, 7, 4388, 10.1038/s41598-017-04137-2 · doi:10.1038/s41598-017-04137-2
- Phan, 2018, Environmental and body contamination from cleaning vomitus in a health care setting: A simulation study, American Journal of Infection Control, 46, 397, 10.1016/j.ajic.2017.10.003 · doi:10.1016/j.ajic.2017.10.003
- Rosenberg, 2016, A simple intervention reduces contamination risk in health care personnel, AJN American Journal of Nursing, 116, 64
- Scott Taylor, 2017, Comparison of intubation devices in level C personal protective equipment: A cadaveric study, The American Journal of Emergency Medicine, 36, 922, 10.1016/j.ajem.2017.10.047 · doi:10.1016/j.ajem.2017.10.047
- Su, 2017, Contact patterns during cleaning of vomitus: a simulation study, Am J Infect Control, 45, 1312, 10.1016/j.ajic.2017.07.005 · doi:10.1016/j.ajic.2017.07.005
- Tomas, 2016, Utility of a novel reflective marker visualized by flash photography for assessment of personnel contamination during removal of personal protective equipment, Infection Control and Hospital Epidemiology, 37, 711, 10.1017/ice.2016.44 · doi:10.1017/ice.2016.44
- Xi, 2016, Improving health care workers' protection against infection of Ebola hemorrhagic fever through video surveillance, American Journal of Infection Control, 44, 922, 10.1016/j.ajic.2016.02.015 · doi:10.1016/j.ajic.2016.02.015
- Veritas Health Innovation Covidence Systematic Review Software 2016
- European Center for Disease Prevention and Control Safe use of personal protective equipment in the treatment of infectious diseases of high consequence ECDC 10.2900/339505 · doi:10.2900/339505
- The Nordic Cochrane Centre, The Cochrane Collaboration Review Manager (RevMan) 2014
Cited by
Chu, D. K., Akl, E. A., Duda, S., Solo, K., Yaacoub, S., Schünemann, H. J., Chu, D. K., Akl, E. A., El-harakeh, A., Bognanni, A., et al. (2020) · The Lancet · doi:10.1016/s0140-6736(20)31142-9 · Cited by 3,843
Verbeek, J. H., Rajamaki, B., Ijaz, S., Sauni, R., Toomey, E., Blackwood, B., Tikka, C., Ruotsalainen, J. H., & Kilinc Balci, F. S. (2020) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011621.pub4 · Cited by 657
Self-citationManaging ICU surge during the COVID-19 crisis: Rapid guidelines.
Aziz, S., Arabi, Y. M., Alhazzani, W., Evans, L., Citerio, G., Fischkoff, K., Salluh, J., Meyfroidt, G., Alshamsi, F., Oczkowski, S., et al. (2020) · Intensive Care Medicine · doi:10.1007/s00134-020-06092-5 · Cited by 380
Yao, W., Wang, T., Jiang, B., Gao, F., Wang, L., Zheng, H., Xiao, W., Yao, S., Mei, W., Chen, X., et al. (2020) · British Journal of Anaesthesia · doi:10.1016/j.bja.2020.03.026 · Cited by 354
MacIntyre, C. R., & Chughtai, A. A. (2020) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2020.103629 · Cited by 319
Metadata
- Authors
- Verbeek, J. H., Rajamaki, B., Ijaz, S., Tikka, C., Ruotsalainen, J. H., Edmond, M. B., Sauni, R., & Kilinc Balci, F. S.
- Venue
- Cochrane Database of Systematic Reviews
- Publisher
- Wiley
- Published
- 2019-07-01
- Volume
- 7
- Pages
- CD011621-CD011621
- ISSN
- 1361-6137 (ISSN-L)
- 1465-1858
- OpenAlex
- W4230014132
- Cited by
- 276
- References
- 150
- FWCI
- 38.27
- Type
- journal article
- Language
- en
- Update notices
- new_version (2020-04-15)
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Personal protective equipment for preventing highly infectious diseases due to exposure to contaminated body fluids in healthcare staff. https://app.cochat.ai/papers/10.1002/14651858.cd011621.pub3
- The paper
- Verbeek, J. H., Rajamaki, B., Ijaz, S., Tikka, C., Ruotsalainen, J. H., Edmond, M. B., Sauni, R., & Kilinc Balci, F. S. (2019). Personal protective equipment for preventing highly infectious diseases due to exposure to contaminated body fluids in healthcare staff. Cochrane Database of Systematic Reviews. https://doi.org/10.1002/14651858.cd011621.pub3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.