CoChat

Use of Machine Learning for Predicting Escitalopram Treatment Outcome From Electroencephalography Recordings in Adult Patients With Depression

Open access
Zhdanov, Andrey, Atluri, Sravya, Wong, Willy, Vaghei, Yasaman, Daskalakis, Zafiris J., Blumberger, Daniel M., Frey, Benicio N., Giacobbe, Peter, Lam, Raymond W., Milev, Roumen, Mueller, Daniel J., Turecki, Gustavo, Parikh, Sagar V., Rotzinger, Susan, Soares, Claudio N., Brenner, Colleen A., Vila-Rodriguez, Fidel, McAndrews, Mary Pat, Kleffner, Killian, Alonso-Prieto, Esther, Arnott, Stephen R., Foster, Jane A., Strother, Stephen C., Uher, Rudolf, Kennedy, Sidney H., Farzan, Faranak · 2020 · JAMA Network Open
Cited by 93

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Abstract

Importance: Social and economic costs of depression are exacerbated by prolonged periods spent identifying treatments that would be effective for a particular patient. Thus, a tool that reliably predicts an individual patient's response to treatment could significantly reduce the burden of depression. Objective: To estimate how accurately an outcome of escitalopram treatment can be predicted from electroencephalographic (EEG) data on patients with depression. Design, Setting, and Participants: This prognostic study used a support vector machine classifier to predict treatment outcome using data from the first Canadian Biomarker Integration Network in Depression (CAN-BIND-1) study. The CAN-BIND-1 study comprised 180 patients (aged 18-60 years) diagnosed with major depressive disorder who had completed 8 weeks of treatment. Of this group, 122 patients had EEG data recorded before the treatment; 115 also had EEG data recorded after the first 2 weeks of treatment. Interventions: All participants completed 8 weeks of open-label escitalopram (10-20 mg) treatment. Main Outcomes and Measures: The ability of EEG data to predict treatment outcome, measured as accuracy, specificity, and sensitivity of the classifier at baseline and after the first 2 weeks of treatment. The treatment outcome was defined in terms of change in symptom severity, measured by the Montgomery-Åsberg Depression Rating Scale, before and after 8 weeks of treatment. A patient was designated as a responder if the Montgomery-Åsberg Depression Rating Scale score decreased by at least 50% during the 8 weeks and as a nonresponder if the score decrease was less than 50%. Results: Of the 122 participants who completed a baseline EEG recording (mean [SD] age, 36.3 [12.7] years; 76 [62.3%] female), the classifier was able to identify responders with an estimated accuracy of 79.2% (sensitivity, 67.3%; specificity, 91.0%) when using only the baseline EEG data. For a subset of 115 participants who had additional EEG data recorded after the first 2 weeks of treatment, use of these data increased the accuracy to 82.4% (sensitivity, 79.2%; specificity, 85.5%). Conclusions and Relevance: These findings demonstrate the potential utility of EEG as a treatment planning tool for escitalopram therapy. Further development of the classification tools presented in this study holds the promise of expediting the search for optimal treatment for each patient.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jamanetworkopen.2019.18377

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 93

Metadata

Authors
Zhdanov, A., Atluri, S., Wong, W., Vaghei, Y., Daskalakis, Z. J., Blumberger, D. M., Frey, B. N., Giacobbe, P., Lam, R. W., Milev, R., Mueller, D. J., Turecki, G., Parikh, S. V., Rotzinger, S., Soares, C. N., Brenner, C. A., Vila-Rodriguez, F., McAndrews, M. P., Kleffner, K., Alonso-Prieto, E., Arnott, S. R., Foster, J. A., Strother, S. C., Uher, R., Kennedy, S. H., & Farzan, F.
Venue
JAMA Network Open
Published
2020-01-03
Volume
3
Issue
1
Pages
e1918377
ISSN
2574-3805 (ISSN-L)
OpenAlex
W2996818987
Cited by
93
References
15
FWCI
5.60
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.