CoChat

Development and Validation of a Tool to Assess the Quality of Clinical Practice Guideline Recommendations

Open access
Brouwers, Melissa C., Spithoff, Karen, Kerkvliet, Kate, Alonso-Coello, Pablo, Burgers, Jako, Cluzeau, Francoise, Férvers, Beatrice, Graham, Ian, Grimshaw, Jeremy, Hanna, Steven, Kastner, Monika, Kho, Michelle, Qaseem, Amir, Straus, Sharon, Florez, Ivan D. · 2020 · JAMA Network Open
Cited by 217

The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.

Abstract

Importance: Clinical practice guidelines (CPGs) may lack rigor and suitability to the setting in which they are to be applied. Methods to yield clinical practice guideline recommendations that are credible and implementable remain to be determined. Objective: To describe the development of AGREE-REX (Appraisal of Guidelines Research and Evaluation-Recommendations Excellence), a tool designed to evaluate the quality of clinical practice guideline recommendations. Design, Setting, and Participants: A cross-sectional study of 322 international stakeholders representing CPG developers, users, and researchers was conducted between December 2015 and March 2019. Advertisements to participate were distributed through professional organizations as well as through the AGREE Enterprise social media accounts and their registered users. Exposures: Between 2015 and 2017, participants appraised 1 of 161 CPGs using the Draft AGREE-REX tool and completed the AGREE-REX Usability Survey. Main Outcomes and Measures: Usability and measurement properties of the tool were assessed with 7-point scales (1 indicating strong disagreement and 7 indicating strong agreement). Internal consistency of items was assessed with the Cronbach α, and the Spearman-Brown reliability adjustment was used to calculate reliability for 2 to 5 raters. Results: A total of 322 participants (202 female participants [62.7%]; 83 aged 40-49 years [25.8%]) rated the survey items (on a 7-point scale). All 11 items were rated as easy to understand (with a mean [SD] ranging from 5.2 [1.38] for the alignment of values item to 6.3 [0.87] for the evidence item) and easy to apply (with a mean [SD] ranging from 4.8 [1.49] for the alignment of values item to 6.1 [1.07] for the evidence item). Participants provided favorable feedback on the tool's instructions, which were considered clear (mean [SD], 5.8 [1.06]), helpful (mean [SD], 5.9 [1.00]), and complete (mean [SD], 5.8 [1.11]). Participants considered the tool easy to use (mean [SD], 5.4 [1.32]) and thought that it added value to the guideline enterprise (mean [SD], 5.9 [1.13]). Internal consistency of the items was high (Cronbach α = 0.94). Positive correlations were found between the overall AGREE-REX score and the implementability score (r = 0.81) and the clinical credibility score (r = 0.76). Conclusions and Relevance: This cross-sectional study found that the AGREE-REX tool can be useful in evaluating CPG recommendations, differentiating among them, and identifying those that are clinically credible and implementable for practicing health professionals and decision makers who use recommendations to inform clinical policy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jamanetworkopen.2020.5535

Cites

37 of 37 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 37 references

Metadata

Authors
Brouwers, M. C., Spithoff, K., Kerkvliet, K., Alonso-Coello, P., Burgers, J., Cluzeau, F., Férvers, B., Graham, I., Grimshaw, J., Hanna, S., Kastner, M., Kho, M., Qaseem, A., Straus, S., & Florez, I. D.
Venue
JAMA Network Open
Published
2020-05-27
Volume
3
Issue
5
Pages
e205535
ISSN
2574-3805 (ISSN-L)
OpenAlex
W3028923082
Cited by
217
References
37
FWCI
19.79
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Development and Validation of a Tool to Assess the Quality of Clinical Practice Guideline Recommendations. https://app.cochat.ai/papers/10.1001/jamanetworkopen.2020.5535
The paper
Brouwers, M. C., Spithoff, K., Kerkvliet, K., Alonso-Coello, P., Burgers, J., Cluzeau, F., Férvers, B., Graham, I., Grimshaw, J., Hanna, S., Kastner, M., Kho, M., Qaseem, A., Straus, S., & Florez, I. D. (2020). Development and Validation of a Tool to Assess the Quality of Clinical Practice Guideline Recommendations. JAMA Network Open. https://doi.org/10.1001/jamanetworkopen.2020.5535

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.