CoChat

Optimizing Descemet Membrane Endothelial Keratoplasty Using Intraoperative Optical Coherence Tomography

Open access
Steven, Philipp, Le Blanc, Carolin, Velten, Kai, Lankenau, Eva, Krug, Marc, Oelckers, Stefan, Heindl, Ludwig M., Gehlsen, Uta, Hüttmann, Gereon, Cursiefen, Claus · 2013 · JAMA Ophthalmology
Cited by 190

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

IMPORTANCE: Descemet membrane endothelial keratoplasty (DMEK) is a challenging procedure for the surgeon, particularly because of deficient visibility of the delicate tissue due to the natural en face view through the operating microscope. A cross-sectional view would greatly enhance intraoperative overview and enable the surgeon to better control the procedure. OBJECTIVE: To retrospectively analyze the use of intraoperative optical coherence tomography (iOCT) for improving the safety of DMEK. DESIGN: Intraoperative OCT during DMEK was performed in 26 eyes of 26 patients. We retrospectively analyzed imaging and video data. SETTING: Department of Ophthalmology, University of Cologne. PARTICIPANTS: Seven men and 19 women aged 39 to 93 years with corneal endothelial dysfunction undergoing DMEK. EXPOSURE: Descemet membrane endothelial keratoplasty. MAIN OUTCOMES AND MEASURES: Visibility of surgical steps, overall duration of DMEK, overall time for complete intraoperative air filling of the anterior chamber, and correlation between donor age and Descemet rolling behavior. RESULTS Intraoperative OCT enables visualization of all steps of the DMEK procedure. Overall mean (SD) duration of the DMEK procedure was 25.7 (6.9) minutes when using iOCT. Overall mean (SD) complete intraoperative anterior chamber air-filling time was 236 (108) seconds in contrast to 60 to 90 minutes for standard air-filling time. Descemet membrane rolling behavior showed significant inverse correlation between donor age (range, 39-93 years) and the extent of rolling (R2 = 0.5 [P = .006]). CONCLUSIONS AND RELEVANCE: Intraoperative OCT enhances the visibility of graft orientation and unfolding, thereby improving safety of the DMEK procedure. Overall, iOCT is a helpful device that may support surgeons in all steps of DMEK procedures.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jamaophthalmol.2013.4672

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 190

Metadata

Authors
Steven, P., Le Blanc, C., Velten, K., Lankenau, E., Krug, M., Oelckers, S., Heindl, L. M., Gehlsen, U., Hüttmann, G., & Cursiefen, C.
Venue
JAMA Ophthalmology
Published
2013-09-01
Volume
131
Issue
9
Pages
1135
ISSN
2168-6165 (ISSN-L)
OpenAlex
W2056620667
Cited by
190
References
11
FWCI
17.11
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.