The Prospective Intraoperative and Perioperative Ophthalmic ImagiNg With Optical CoherEncE TomogRaphy (PIONEER) Study: 2-Year Results
Open accessThe DOI matches its Crossref record.
Abstract
Purpose To evaluate the feasibility, safety, and utility of intraoperative optical coherence tomography (OCT) for use during ophthalmic surgery. Design Prospective, consecutive, case series Methods A prospective, single-center, consecutive, case series was initiated to assess intraoperative OCT in ophthalmic surgery. Intraoperative scanning was performed with a microscope mounted spectral domain OCT system. Disease specific or procedure-specific imaging protocols (e.g., scan type, pattern, size, orientation, density) were utilized for anterior and posterior segment applications. A surgeon feedback form was recorded as part of the study protocol to answer specific questions regarding intraoperative OCT utility immediately after the surgical procedure was completed. Results During the first 24 months of the PIONEER study, 531 eyes were enrolled (275 anterior segment cases and 256 posterior segment surgical cases). Intraoperative OCT imaging was obtained in 518 of 531 eyes (98%). Surgeon feedback indicated that intraoperative OCT informed surgical decision-making and altered surgeon understanding of underlying tissue configurations in 69/144 (48%) lamellar keratoplasty cases and 63/146 (43%) membrane peeling procedures. The most common anterior segment surgical procedure was descemet stripping automated endothelial keratoplasty (DSAEK, n = 135). Vitrectomy with membrane peeling was the most common procedure for posterior segment surgery (n = 154). The median time that surgery was paused to perform intraoperative OCT was 4.9 minutes per scan session. No adverse events were specifically attributed to intraoperative OCT scanning during the procedure. Conclusions Intraoperative OCT is feasible for numerous anterior and posterior segment ophthalmic surgical procedures. A microscope mounted intraoperative OCT system provided efficient imaging during operative procedures. The information gained from intraoperative OCT may impact surgical decision-making in a high frequency of both anterior and posterior segment cases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Light in diagnosis, therapy and surgery
Yun, S. H., & Kwok, S. J. J. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-016-0008 · Cited by 793
Intraoperative optical coherence tomography: past, present, and future
Ehlers, J. P. (2016) · Eye · doi:10.1038/eye.2015.255 · Cited by 77
Self-citationGregori, N. Z., Lam, B. L., & Davis, J. L. (2019) · Retina · doi:10.1097/iae.0000000000001646 · Cited by 54
Metadata
- Authors
- Ehlers, J. P., Dupps, W. J., Kaiser, P. K., Goshe, J., Singh, R. P., Petkovsek, D., & Srivastava, S. K.
- Venue
- American Journal of Ophthalmology
- Publisher
- Elsevier BV
- Published
- 2014-11
- Volume
- 158
- Issue
- 5
- Pages
- 999-1007.e1
- ISSN
- 0002-9394 (ISSN-L)
- OpenAlex
- W2083877223
- Cited by
- 225
- References
- 0
- FWCI
- 11.09
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Prospective Intraoperative and Perioperative Ophthalmic ImagiNg With Optical CoherEncE TomogRaphy (PIONEER) Study: 2-Year Results. https://app.cochat.ai/papers/10.1016/j.ajo.2014.07.034
- The paper
- Ehlers, J. P., Dupps, W. J., Kaiser, P. K., Goshe, J., Singh, R. P., Petkovsek, D., & Srivastava, S. K. (2014). The Prospective Intraoperative and Perioperative Ophthalmic ImagiNg With Optical CoherEncE TomogRaphy (PIONEER) Study: 2-Year Results. American Journal of Ophthalmology. https://doi.org/10.1016/j.ajo.2014.07.034
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.