Evaluation of Automated Teleretinal Screening Program for Diabetic Retinopathy
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
IMPORTANCE: Diabetic retinopathy is a leading cause of blindness, but its detrimental effects are preventable with early detection and treatment. Screening for diabetic retinopathy has the potential to increase the number of cases treated early, especially in populations with limited access to care. OBJECTIVE: To determine the efficacy of an automated algorithm in interpreting screening ophthalmoscopic photographs from patients with diabetes compared with a reading center interpretation. DESIGN, SETTING, AND PARTICIPANTS: Retrospective cohort analysis of 15,015 patients with type 1 or 2 diabetes in the Harris Health System in Harris County, Texas, who had undergone a retinal screening examination and nonmydriatic fundus photography via the Intelligent Retinal Imaging System (IRIS) from June 2013 to April 2014 were included. The IRIS-based interpretations were compared with manual interpretation. The IRIS algorithm population statistics were calculated. MAIN OUTCOMES AND MEASURES: Sensitivity and false-negative rate of the IRIS computer-based algorithm compared with reading center interpretation of the same images. RESULTS: A total of 15 015 consecutive patients (aged 18-98 years); mean 54.3 years with known type 1 or 2 diabetes underwent nonmydriatic fundus photography for a diabetic retinopathy screening examination. The sensitivity of the IRIS algorithm in detecting sight-threatening diabetic eye disease compared with the reading center interpretation was 66.4% (95% CI, 62.8%-69.9%) with a false-negative rate of 2%. The specificity was 72.8% (95% CI, 72.0%-73.5%). In a population where 15.8% of people with diabetes have sight-threatening diabetic eye disease, the IRIS algorithm positive predictive value was 10.8% (95% CI, 9.6%-11.9%) and the negative predictive value was 97.8% (95% CI, 96.8%-98.6%). CONCLUSIONS AND RELEVANCE: In this large urban setting, the IRIS computer algorithm-based screening program had a high sensitivity and a low false-negative rate, suggesting that it may be an effective alternative to conventional reading center image interpretation. The IRIS algorithm shows promise as a screening program, but algorithm refinement is needed to achieve better performance. Further studies of patient safety, cost-effectiveness, and widespread applications of this type of algorithm should be pursued to better understand the role of teleretinal imaging and automated analysis in the global health care system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prevalence of Diabetic Retinopathy in the United States, 2005-2008
Zhang, X., Saaddine, J. B., Chou, C.-F., Cotch, M. F., Cheng, Y. J., Geiss, L. S., Gregg, E. W., Albright, A. L., Klein, B. E. K., & Klein, R. (2010) · JAMA · doi:10.1001/jama.2010.1111 · Cited by 1,196
Saaddine, J. B. (2008) · Archives of Ophthalmology · doi:10.1001/archopht.126.12.1740 · Cited by 377
Mansberger, S. L., Sheppler, C., Barker, G., Gardiner, S. K., Demirel, S., Wooten, K., & Becker, T. M. (2015) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2015.1 · Cited by 177
Khan, T., Bertram, M. Y., Jina, R., Mash, B., Levitt, N., & Hofman, K. (2013) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2013.05.006 · Cited by 74
Cited by
How to Read Articles That Use Machine Learning: Users’ Guides to the Medical Literature
Liu, Y., Chen, P.-H. C., Krause, J., & Peng, L. (2019) · JAMA · doi:10.1001/jama.2019.16489 · Cited by 516
Rajalakshmi, R., Subashini, R., Anjana, R. M., & Mohan, V. (2018) · Eye · doi:10.1038/s41433-018-0064-9 · Cited by 462
Tan, G. S., Cheung, N., Simó, R., Cheung, G. C. M., & Wong, T. Y. (2017) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(16)30052-3 · Cited by 361
10. Microvascular Complications and Foot Care: Standards of Medical Care in Diabetes—2018
American Diabetes Association (2018) · Diabetes Care · doi:10.2337/dc18-s010 · Cited by 302
Artificial Intelligence With Deep Learning Technology Looks Into Diabetic Retinopathy Screening
Wong, T. Y., & Bressler, N. M. (2016) · JAMA · doi:10.1001/jama.2016.17563 · Cited by 271
Metadata
- Authors
- Walton, O. B., Garoon, R. B., Weng, C. Y., Gross, J., Young, A. K., Camero, K. A., Jin, H., Carvounis, P. E., Coffee, R. E., & Chu, Y. I.
- Venue
- JAMA Ophthalmology
- Publisher
- American Medical Association (AMA)
- Published
- 2016-02-01
- Volume
- 134
- Issue
- 2
- Pages
- 204
- ISSN
- 2168-6165 (ISSN-L)
- OpenAlex
- W2198862892
- Cited by
- 108
- References
- 5
- FWCI
- 7.88
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of Automated Teleretinal Screening Program for Diabetic Retinopathy. https://app.cochat.ai/papers/10.1001/jamaophthalmol.2015.5083
- The paper
- Walton, O. B., Garoon, R. B., Weng, C. Y., Gross, J., Young, A. K., Camero, K. A., Jin, H., Carvounis, P. E., Coffee, R. E., & Chu, Y. I. (2016). Evaluation of Automated Teleretinal Screening Program for Diabetic Retinopathy. JAMA Ophthalmology. https://doi.org/10.1001/jamaophthalmol.2015.5083
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.