CoChat

Evaluation of Automated Teleretinal Screening Program for Diabetic Retinopathy

Open access
Walton, O. Bennett, Garoon, Robert B., Weng, Christina Y., Gross, Jacob, Young, Alex K., Camero, Kathryn A., Jin, Haoxing, Carvounis, Petros E., Coffee, Robert E., Chu, Yvonne I. · 2016 · JAMA Ophthalmology
Cited by 108

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

IMPORTANCE: Diabetic retinopathy is a leading cause of blindness, but its detrimental effects are preventable with early detection and treatment. Screening for diabetic retinopathy has the potential to increase the number of cases treated early, especially in populations with limited access to care. OBJECTIVE: To determine the efficacy of an automated algorithm in interpreting screening ophthalmoscopic photographs from patients with diabetes compared with a reading center interpretation. DESIGN, SETTING, AND PARTICIPANTS: Retrospective cohort analysis of 15,015 patients with type 1 or 2 diabetes in the Harris Health System in Harris County, Texas, who had undergone a retinal screening examination and nonmydriatic fundus photography via the Intelligent Retinal Imaging System (IRIS) from June 2013 to April 2014 were included. The IRIS-based interpretations were compared with manual interpretation. The IRIS algorithm population statistics were calculated. MAIN OUTCOMES AND MEASURES: Sensitivity and false-negative rate of the IRIS computer-based algorithm compared with reading center interpretation of the same images. RESULTS: A total of 15 015 consecutive patients (aged 18-98 years); mean 54.3 years with known type 1 or 2 diabetes underwent nonmydriatic fundus photography for a diabetic retinopathy screening examination. The sensitivity of the IRIS algorithm in detecting sight-threatening diabetic eye disease compared with the reading center interpretation was 66.4% (95% CI, 62.8%-69.9%) with a false-negative rate of 2%. The specificity was 72.8% (95% CI, 72.0%-73.5%). In a population where 15.8% of people with diabetes have sight-threatening diabetic eye disease, the IRIS algorithm positive predictive value was 10.8% (95% CI, 9.6%-11.9%) and the negative predictive value was 97.8% (95% CI, 96.8%-98.6%). CONCLUSIONS AND RELEVANCE: In this large urban setting, the IRIS computer algorithm-based screening program had a high sensitivity and a low false-negative rate, suggesting that it may be an effective alternative to conventional reading center image interpretation. The IRIS algorithm shows promise as a screening program, but algorithm refinement is needed to achieve better performance. Further studies of patient safety, cost-effectiveness, and widespread applications of this type of algorithm should be pursued to better understand the role of teleretinal imaging and automated analysis in the global health care system.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jamaophthalmol.2015.5083

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 108

Metadata

Authors
Walton, O. B., Garoon, R. B., Weng, C. Y., Gross, J., Young, A. K., Camero, K. A., Jin, H., Carvounis, P. E., Coffee, R. E., & Chu, Y. I.
Venue
JAMA Ophthalmology
Published
2016-02-01
Volume
134
Issue
2
Pages
204
ISSN
2168-6165 (ISSN-L)
OpenAlex
W2198862892
Cited by
108
References
5
FWCI
7.88
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of Automated Teleretinal Screening Program for Diabetic Retinopathy. https://app.cochat.ai/papers/10.1001/jamaophthalmol.2015.5083
The paper
Walton, O. B., Garoon, R. B., Weng, C. Y., Gross, J., Young, A. K., Camero, K. A., Jin, H., Carvounis, P. E., Coffee, R. E., & Chu, Y. I. (2016). Evaluation of Automated Teleretinal Screening Program for Diabetic Retinopathy. JAMA Ophthalmology. https://doi.org/10.1001/jamaophthalmol.2015.5083

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.