CoChat

Low-Shot Deep Learning of Diabetic Retinopathy With Potential Applications to Address Artificial Intelligence Bias in Retinal Diagnostics and Rare Ophthalmic Diseases

Open access
Burlina, Philippe, Paul, William, Mathew, Philip, Joshi, Neil, Pacheco, Katia D., Bressler, Neil M. · 2020 · JAMA Ophthalmology
Cited by 76

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

Importance: Recent studies have demonstrated the successful application of artificial intelligence (AI) for automated retinal disease diagnostics but have not addressed a fundamental challenge for deep learning systems: the current need for large, criterion standard-annotated retinal data sets for training. Low-shot learning algorithms, aiming to learn from a relatively low number of training data, may be beneficial for clinical situations involving rare retinal diseases or when addressing potential bias resulting from data that may not adequately represent certain groups for training, such as individuals older than 85 years. Objective: To evaluate whether low-shot deep learning methods are beneficial when using small training data sets for automated retinal diagnostics. Design, Setting, and Participants: This cross-sectional study, conducted from July 1, 2019, to June 21, 2020, compared different diabetic retinopathy classification algorithms, traditional and low-shot, for 2-class designations (diabetic retinopathy warranting referral vs not warranting referral). The public domain EyePACS data set was used, which originally included 88 692 fundi from 44 346 individuals. Statistical analysis was performed from February 1 to June 21, 2020. Main Outcomes and Measures: The performance (95% CIs) of the various AI algorithms was measured via receiver operating curves and their area under the curve (AUC), precision recall curves, accuracy, and F1 score, evaluated for different training data sizes, ranging from 5120 to 10 samples per class. Results: Deep learning algorithms, when trained with sufficiently large data sets (5120 samples per class), yielded comparable performance, with an AUC of 0.8330 (95% CI, 0.8140-0.8520) for a traditional approach (eg, fined-tuned ResNet), compared with low-shot methods (AUC, 0.8348 [95% CI, 0.8159-0.8537]) (using self-supervised Deep InfoMax [our method denoted as DIM]). However, when far fewer training images were available (n = 160), the traditional deep learning approach had an AUC decreasing to 0.6585 (95% CI, 0.6332-0.6838) and was outperformed by a low-shot method using self-supervision with an AUC of 0.7467 (95% CI, 0.7239-0.7695). At very low shots (n = 10), the traditional approach had performance close to chance, with an AUC of 0.5178 (95% CI, 0.4909-0.5447) compared with the best low-shot method (AUC, 0.5778 [95% CI, 0.5512-0.6044]). Conclusions and Relevance: These findings suggest the potential benefits of using low-shot methods for AI retinal diagnostics when a limited number of annotated training retinal images are available (eg, with rare ophthalmic diseases or when addressing potential AI bias).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jamaophthalmol.2020.3269

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 76

Metadata

Authors
Burlina, P., Paul, W., Mathew, P., Joshi, N., Pacheco, K. D., & Bressler, N. M.
Venue
JAMA Ophthalmology
Published
2020-10-01
Volume
138
Issue
10
Pages
1070
ISSN
2168-6165 (ISSN-L)
OpenAlex
W3081762707
Cited by
76
References
10
FWCI
5.15
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Low-Shot Deep Learning of Diabetic Retinopathy With Potential Applications to Address Artificial Intelligence Bias in Retinal Diagnostics and Rare Ophthalmic Diseases. https://app.cochat.ai/papers/10.1001/jamaophthalmol.2020.3269
The paper
Burlina, P., Paul, W., Mathew, P., Joshi, N., Pacheco, K. D., & Bressler, N. M. (2020). Low-Shot Deep Learning of Diabetic Retinopathy With Potential Applications to Address Artificial Intelligence Bias in Retinal Diagnostics and Rare Ophthalmic Diseases. JAMA Ophthalmology. https://doi.org/10.1001/jamaophthalmol.2020.3269

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.