CoChat

A New Scoring System for Upper Airway Pediatric Sleep Endoscopy

Chan, Dylan K., Liming, Bryan J., Horn, David L., Parikh, Sanjay R. · 2014 · JAMA Otolaryngology–Head & Neck Surgery
Cited by 103

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

IMPORTANCE: Sleep-associated upper-airway obstruction in children is a significant cause of morbidity. Development of a simple, standardized, quantitative technique to assess anatomic causes of sleep-related breathing disorder is important for surgical planning, clinical communication, and research. OBJECTIVE: To design, implement, and evaluate a scoring system to quantify airway obstruction in pediatric drug-induced sleep endoscopy. DESIGN, SETTING, AND PARTICIPANTS: This study was a retrospective case series conducted at a tertiary pediatric hospital. The patients were children with sleep-related breathing disorder who underwent polysomnography and drug-induced sleep endoscopy. INTERVENTIONS: Flexible fiber-optic laryngoscopy was performed. Endoscopic examinations were recorded on video and assessed by 4 independent raters based on a scoring template. MAIN OUTCOMES AND MEASURES: Five locations in the upper aerodigestive tract (adenoid, velum, lateral pharyngeal wall, tongue base, and supraglottis) were evaluated on a 4-point scale for minimum and maximum obstruction. Internal reliability was assessed by calculating interrater and intrarater intraclass correlation coefficients (ICCs). For external validation, aggregate and site-specific scores were correlated with preoperative polysomnographic indices. RESULTS: Videos recorded of sleep endoscopies from 23 children (mean age, 2.2 years) were reviewed and rated. Children had an average apnea-hypopnea index of 24.8. Seventy percent of interrater and intrarater ICC values (7 of 10 for each set) were above 0.6, demonstrating substantial agreement. Higher total obstructive scores were associated with lower oxygen saturation nadir (P = .04). The scoring system was also used to quantitatively identify children with multilevel airway obstruction, who were found to have significantly worse polysomnographic indices compared with children with single-level obstruction (P = .02). CONCLUSIONS AND RELEVANCE: The proposed scoring system, which is designed to be easy to use and allow for subjectivity in evaluating obstruction at multiple levels, nonetheless achieves good internal reliability and external validity. Implementing this system will allow for standardization of reporting for sleep endoscopy outcomes, as well as aid the practicing clinician in the interpretation of sleep endoscopy findings to inform site-directed surgical intervention in cases of complicated obstructive sleep apnea.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jamaoto.2014.612

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 103

Metadata

Authors
Chan, D. K., Liming, B. J., Horn, D. L., & Parikh, S. R.
Venue
JAMA Otolaryngology–Head & Neck Surgery
Published
2014-07-01
Volume
140
Issue
7
Pages
595
ISSN
2168-6181 (ISSN-L)
OpenAlex
W2075476127
Cited by
103
References
3
FWCI
4.28
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A New Scoring System for Upper Airway Pediatric Sleep Endoscopy. https://app.cochat.ai/papers/10.1001/jamaoto.2014.612
The paper
Chan, D. K., Liming, B. J., Horn, D. L., & Parikh, S. R. (2014). A New Scoring System for Upper Airway Pediatric Sleep Endoscopy. JAMA Otolaryngology–Head & Neck Surgery. https://doi.org/10.1001/jamaoto.2014.612

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.