CoChat

Systematic Review of Drug‐Induced Sleep Endoscopy Scoring Systems

The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.

Abstract

Objective: To systematically review the scoring systems used to report findings during drug‐induced sleep endoscopy (DISE) for adults and children with obstructive sleep apnea. Data Sources: PubMed, CINAHL, EBM Reviews, Embase, and Scopus databases. Review Methods: This is a systematic review of all indexed years of publications referring to scoring of DISE for children and adults with obstructive sleep apnea. The type of DISE scoring system utilized was the primary outcome. PRISMA guidelines were followed to carry out this review; articles were independently reviewed by 2 investigators. All pediatric and adult studies that utilized ≥1 DISE grading systems were included. Results: Of 492 identified abstracts, 44 articles (combined population, N = 5784) were ultimately included; 6 reported on children, 35 on adults, and 1 on children and adults. Twenty‐one reporting methods were used in these studies, with the most common being the VOTE system (velum, oropharynx, tongue base, and epiglottis; 38.6%) and the Pringle and Croft classification (15.9%). The sites of obstruction most commonly included in a scoring system were the tongue base (62%), lateral pharynx/oropharynx (57%), palate (57%), epiglottis/supraglottis (38%), and hypopharynx (38%). Less commonly included sites were the larynx (29%), velum (23%), nose (23%), tongue (14%), adenoids (10%), and nasopharynx (10%). Conclusion: There is no consensus regarding which scoring system should be utilized to report findings during DISE. The VOTE system and the Pringle and Croft classification were the most frequent scoring systems reported for patients undergoing DISE. Standardization of the reporting of DISE findings would improve comparability among studies.

Overview

Integrity signals

Registry

Crossref · 10.1177/0194599817737966

Cites

46 of 46 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 46 references

Research works printed but not linked: 1

  1. Suslu AE, 2006, Comparison of two endoscopic examination methods, the Muller maneuver and fiberoptic pharyngocopy during sleep in patients, Kulak Burun Bogaz Ihtis Derg, 16, 200

Cited by

See all 72

Metadata

Authors
Amos, J. M., Durr, M. L., Nardone, H. C., Baldassari, C. M., Duggins, A., & Ishman, S. L.
Affiliations
  • McLaren Health Care (US)
  • Kaiser Permanente (US)
  • Alfred I. duPont Hospital for Children (US)
  • Eastern Virginia Medical School (US)
  • Cincinnati Children's Hospital Medical Center (US)
Corresponding author
Amos, Janine M.
Venue
Otolaryngology–Head and Neck Surgery
Publisher
Wiley
Published
2017-10-24
Volume
158
Issue
2
Pages
240-248
ISSN
  • 0161-6439 (ISSN-L)
  • 0194-5998
  • 1097-6817
OpenAlex
W2765837717
Cited by
66
References
46
Citations by year
2025: 5 · 2024: 4 · 2023: 11 · 2022: 11 · 2021: 11 · 2020: 7 · 2019: 10 · 2018: 7
FWCI
0.81
Type
journal article
Language
en
Open access
closed
Locations
  • Otolaryngology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
  • Health Sciences › Medicine › Surgery › Nasal Surgery and Airway Studies
  • Health Sciences › Medicine › Anesthesiology and Pain Medicine › Airway Management and Intubation Techniques
Keywords
drug-induced sleep endoscopy, obstructive sleep apnea, scoring system, airway obstruction site, standardized reporting, pediatric sleep apnea, adult sleep apnea
MeSH terms
Adult, Child, Humans, Hypnotics and Sedatives, Laryngoscopy, Sleep, Polysomnography, Sleep Apnea, Obstructive

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Systematic Review of Drug‐Induced Sleep Endoscopy Scoring Systems. https://app.cochat.ai/papers/10.1177/0194599817737966
The paper
Amos, J. M., Durr, M. L., Nardone, H. C., Baldassari, C. M., Duggins, A., & Ishman, S. L. (2018). Systematic Review of Drug‐Induced Sleep Endoscopy Scoring Systems. Otolaryngology–Head and Neck Surgery. https://doi.org/10.1177/0194599817737966

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.