CoChat

The Effectiveness of Prophylactic Inferior Vena Cava Filters in Trauma Patients: A Systematic Review and Meta-analysis

Haut, Elliott R., Garcia, Luis J., Shihab, Hasan M., Brotman, Daniel J., Stevens, Kent A., Sharma, Ritu, Chelladurai, Yohalakshmi, Akande, Tokunbo O., Shermock, Kenneth M., Kebede, Sosena, Segal, Jodi B., Singh, Sonal · 2014 · JAMA Surgery
Cited by 158

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

IMPORTANCE: Trauma is known to be one of the strongest risk factors for pulmonary embolism (PE). Current guidelines recommend low-molecular-weight heparin therapy for prevention of PE, but trauma places some patients at risk of excess bleeding. Experts are divided on the role of prophylactic inferior vena cava (IVC) filters to prevent PE. OBJECTIVE: To perform a systematic review and meta-analysis examining the comparative effectiveness of prophylactic IVC filters in trauma patients, particularly in preventing PE, fatal PE, and mortality. DATA SOURCES: We searched the following databases for primary studies: MEDLINE, EMBASE, Scopus, CINAHL, International Pharmaceutical Abstracts, clinicaltrial.gov, and the Cochrane Library (all through July 31, 2012). We developed a search strategy using medical subject headings terms and text words of key articles that we identified a priori. We reviewed the references of all included articles, relevant review articles, and related systematic reviews to identify articles the database searches might have missed. STUDY SELECTION: We reviewed titles followed by abstracts to identify randomized clinical trials or observational studies with comparison groups reporting on the effectiveness and/or safety of IVC filters for prevention of venous thromboembolism in trauma patients. DATA EXTRACTION AND SYNTHESIS: Two investigators independently reviewed abstracts and abstracted data. For studies amenable to pooling with meta-analysis, we pooled using the random-effects model to analyze the relative risks. We graded the quantity, quality, and consistency of the evidence by adapting an evidence-grading scheme recommended by the Agency for Healthcare Research and Quality. RESULTS: Eight controlled studies compared the effectiveness of no IVC filter vs IVC filter on PE, fatal PE, deep vein thrombosis, and/or mortality in trauma patients. Evidence showed a consistent reduction of PE (relative risk, 0.20 [95% CI, 0.06-0.70]; I(2)=0%) and fatal PE (0.09 [0.01-0.81]; I(2)=0%) with IVC filter placement, without any statistical heterogeneity. We found no significant difference in the incidence of deep vein thrombosis (relative risk, 1.76 [95% CI, 0.50-6.19]; P=.38; I(2)=56.8%) or mortality (0.70 [0.40-1.23]; I(2)=6.7%). The number needed to treat to prevent 1 additional PE with IVC filters is estimated to range from 109 (95% CI, 93-190) to 962 (819-2565), depending on the baseline PE risk. CONCLUSIONS AND RELEVANCE: The strength of evidence is low but supports the association of IVC filter placement with a lower incidence of PE and fatal PE in trauma patients. Which patients experience benefit enough to outweigh the harms associated with IVC filter placement remains unclear. Additional well-designed observational or prospective cohort studies may be informative.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jamasurg.2013.3970

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 158

Metadata

Authors
Haut, E. R., Garcia, L. J., Shihab, H. M., Brotman, D. J., Stevens, K. A., Sharma, R., Chelladurai, Y., Akande, T. O., Shermock, K. M., Kebede, S., Segal, J. B., & Singh, S.
Venue
JAMA Surgery
Published
2014-02-01
Volume
149
Issue
2
Pages
194
ISSN
2168-6254 (ISSN-L)
OpenAlex
W1965078999
Cited by
158
References
8
FWCI
11.85
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.