The DOI matches its Crossref record.
A Multicenter Trial of Vena Cava Filters in Severely Injured Patients
Open accessAbstract
BACKGROUND: Whether early placement of an inferior vena cava filter reduces the risk of pulmonary embolism or death in severely injured patients who have a contraindication to prophylactic anticoagulation is not known. METHODS: In this multicenter, randomized, controlled trial, we assigned 240 severely injured patients (Injury Severity Score >15 [scores range from 0 to 75, with higher scores indicating more severe injury]) who had a contraindication to anticoagulant agents to have a vena cava filter placed within the first 72 hours after admission for the injury or to have no filter placed. The primary end point was a composite of symptomatic pulmonary embolism or death from any cause at 90 days after enrollment; a secondary end point was symptomatic pulmonary embolism between day 8 and day 90 in the subgroup of patients who survived at least 7 days and did not receive prophylactic anticoagulation within 7 days after injury. All patients underwent ultrasonography of the legs at 2 weeks; patients also underwent mandatory computed tomographic pulmonary angiography when prespecified criteria were met. RESULTS: The median age of the patients was 39 years, and the median Injury Severity Score was 27. Early placement of a vena cava filter did not result in a significantly lower incidence of symptomatic pulmonary embolism or death than no placement of a filter (13.9% in the vena cava filter group and 14.4% in the control group; hazard ratio, 0.99; 95% confidence interval [CI], 0.51 to 1.94; P = 0.98). Among the 46 patients in the vena cava filter group and the 34 patients in the control group who did not receive prophylactic anticoagulation within 7 days after injury, pulmonary embolism developed in none of those in the vena cava filter group and in 5 (14.7%) in the control group, including 1 patient who died (relative risk of pulmonary embolism, 0; 95% CI, 0.00 to 0.55). An entrapped thrombus was found in the filter in 6 patients. CONCLUSIONS: Early prophylactic placement of a vena cava filter after major trauma did not result in a lower incidence of symptomatic pulmonary embolism or death at 90 days than no placement of a filter. (Funded by the Medical Research Foundation of Royal Perth Hospital and others; Australian New Zealand Clinical Trials Registry number, ACTRN12614000963628.).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Heart Disease and Stroke Statistics—2023 Update: A Report From the American Heart Association
Tsao, C. W., Aday, A. W., Almarzooq, Z. I., Anderson, C. A. M., Arora, P., Avery, C. L., Baker-Smith, C. M., Beaton, A. Z., Boehme, A. K., Buxton, A. E., et al. (2023) · Circulation · doi:10.1161/cir.0000000000001123 · Cited by 8,300
Heart Disease and Stroke Statistics—2022 Update: A Report From the American Heart Association
Tsao, C. W., Aday, A. W., Almarzooq, Z. I., Alonso, A., Beaton, A. Z., Bittencourt, M. S., Boehme, A. K., Buxton, A. E., Carson, A. P., Commodore-Mensah, Y., et al. (2022) · Circulation · doi:10.1161/cir.0000000000001052 · Cited by 5,987
Heart Disease and Stroke Statistics—2021 Update: A Report From the American Heart Association
Virani, S. S., Alonso, A., Aparicio, H. J., Benjamin, E. J., Bittencourt, M. S., Callaway, C. W., Carson, A. P., Chamberlain, A. M., Cheng, S., Delling, F. N., et al. (2021) · Circulation · doi:10.1161/cir.0000000000000950 · Cited by 5,784
Martin, S. S., Aday, A. W., Almarzooq, Z. I., Anderson, C. A. M., Arora, P., Avery, C. L., Baker-Smith, C. M., Barone Gibbs, B., Beaton, A. Z., Boehme, A. K., et al. (2024) · Circulation · doi:10.1161/cir.0000000000001209 · Cited by 2,800
Martin, S. S., Aday, A. W., Allen, N. B., Almarzooq, Z. I., Anderson, C. A. M., Arora, P., Avery, C. L., Baker-Smith, C. M., Bansal, N., Beaton, A. Z., et al. (2025) · Circulation · doi:10.1161/cir.0000000000001303 · Cited by 1,080
Metadata
- Authors
- Ho, K. M., Rao, S., Honeybul, S., Zellweger, R., Wibrow, B., Lipman, J., Holley, A., Kop, A., Geelhoed, E., Corcoran, T., Misur, P., Edibam, C., Baker, R. I., Chamberlain, J., Forsdyke, C., & Rogers, F. B.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2019-07-25
- Volume
- 381
- Issue
- 4
- Pages
- 328-337
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2955669213
- Cited by
- 159
- References
- 0
- FWCI
- 16.72
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Multicenter Trial of Vena Cava Filters in Severely Injured Patients. https://app.cochat.ai/papers/10.1056/nejmoa1806515
- The paper
- Ho, K. M., Rao, S., Honeybul, S., Zellweger, R., Wibrow, B., Lipman, J., Holley, A., Kop, A., Geelhoed, E., Corcoran, T., Misur, P., Edibam, C., Baker, R. I., Chamberlain, J., Forsdyke, C., & Rogers, F. B. (2019). A Multicenter Trial of Vena Cava Filters in Severely Injured Patients. New England Journal of Medicine. https://doi.org/10.1056/nejmoa1806515
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.