Measurement of Heme Concentration
The DOI matches its Crossref record.
Abstract
Heme (iron protoporphyrin IX) is a prosthetic group for a number of hemoproteins in different tissues (e.g., hemoglobin, myoglobin, cytochrome P‐450s, mitochondrial cytochromes, catalases, and peroxidases). Mutations in the biosynthetic pathway can affect the synthesis and/or degradation of heme. Several assays are provided in this unit for quantifying heme: a spectophotometric assay based on the characteristic absorption spectrum of oxidized and reduced form of the hemochrome formed by replacing the nitrogen ligands with pyridine; a fluorescence assay based on removal of the iron by a heated, strong oxalic acid solution to produce fluorescent protoporphyrin; a reversed‐phase HPLC assay to measure heme and intermediates in the synthetic pathway; and a radiometric assay to measure newly synthesized heme in tissue culture cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Performance of high-loaded ANAMMOX UASB reactors containing granular sludge
Tang, C.-J., Zheng, P., Wang, C.-H., Mahmood, Q., Zhang, J.-Q., Chen, X.-G., Zhang, L., & Chen, J.-W. (2011) · Water Research · doi:10.1016/j.watres.2010.08.018 · Cited by 653
The mitochondrial heme exporter FLVCR1b mediates erythroid differentiation
Chiabrando, D., Marro, S., Mercurio, S., Giorgi, C., Petrillo, S., Vinchi, F., Fiorito, V., Fagoonee, S., Camporeale, A., Turco, E., et al. (2012) · Journal of Clinical Investigation · doi:10.1172/jci62422 · Cited by 200
“Intracellular heme concentration was measured using a fluorescence assay, as previously reported (34).”
Distribution and accumulation of dietary ergothioneine and its metabolites in mouse tissues
Tang, R. M. Y., Cheah, I. K.-M., Yew, T. S. K., & Halliwell, B. (2018) · Scientific Reports · doi:10.1038/s41598-018-20021-z · Cited by 163
Reinhart, A. A., Powell, D. A., Nguyen, A. T., O'Neill, M., Djapgne, L., Wilks, A., Ernst, R. K., & Oglesby-Sherrouse, A. G. (2015) · Infection and Immunity · doi:10.1128/iai.02707-14 · Cited by 97
“determined by pyridine hemochrome assay as previously described (42), using the following extinction coefficients: ε 170.”
MethodAppoptosin is a Novel Pro-Apoptotic Protein and Mediates Cell Death in Neurodegeneration
Zhang, H., Zhang, Y.-W., Chen, Y., Huang, X., Zhou, F., Wang, W., Xian, B., Zhang, X., Masliah, E., Chen, Q., et al. (2012) · The Journal of Neuroscience · doi:10.1523/jneurosci.3668-12.2012 · Cited by 68
“Cellular heme concentrations were measured based on a fluorescence assay in which iron is removed by heating in a strong oxalic acid solution and the resultant protoporphyrin is measured by fluorescence (Sinclair et al., 2001).”
Method
Metadata
- Authors
- Sinclair, P. R., Gorman, N., & Jacobs, J. M.
- Venue
- Current Protocols in Toxicology
- Publisher
- Wiley
- Published
- 1999-05
- Volume
- 00
- Issue
- 1
- Pages
- Unit 8.3-Unit 8.3
- ISSN
- 1934-9254 (ISSN-L)
- 1934-9262
- OpenAlex
- W1594726832
- Cited by
- 140
- References
- 0
- FWCI
- 0.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.