Metal‐Chelate Affinity Chromatography
The DOI matches its Crossref record, with a small difference in title or year.
Abstract
Recombinant proteins engineered to have six consecutive histidine residues on either the amino or carboxy terminus can be purified using a resin containing nickel ions (Ni 2+) that have been immobilized by covalently attached nitrilotriacetic acid (NTA). This technique is know as metal‐chelate affinity chromatography and can be performed using either native or denatured protein. This unit presents protocols for expression of histidine‐tail fusion proteins and their purification in either native or denatured form (along with procedures for renaturation by either dialysis or solid‐phase renaturation). Also provided are procedures for analysis of the purified produce and regeneration of the NTA resin.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“These tags allow for facile purification by nickel (Ni2+) bead systems (Petty, 2001).”
From ALARM NMR for HTS Triage and Chemical Probe Validation (2018) · cites this paper as Petty, 2001
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 23
- 10.1016/0003-2697(86)90523-3 · DOI · Paper page
- Botting C.H., 1995, Reporter enzyme–nitrilotriacetic acid–nickel conjugates: Reagents for detecting histidine‐tagged proteins, Biotechniques, 19, 362
- 10.1073/pnas.90.4.1440 · DOI · Paper page
- Hochuli E., 1990, Genetic Engineering, Principles and Practice, Vol. 12, 87
- 10.1016/S0021-9673(00)93969-4 · DOI · Paper page
- 10.1038/nbt1188-1321 · DOI · Paper page
- 10.1093/nar/19.22.6337 · DOI · Paper page
- 10.1016/0003-2697(90)90403-V · doi:10.1016/0003-2697(90)90403-v
- 10.1016/S0021-9673(00)96090-4 · doi:10.1016/s0021-9673(00)96090-4
- 10.1073/pnas.88.20.8972 · DOI · Paper page
- 10.1016/0378-1119(92)90137-E · doi:10.1016/0378-1119(92)90137-e
- 10.1016/0021-9673(92)85151-I · doi:10.1016/0021-9673(92)85151-i
- 10.1016/0021-9673(92)85524-W · DOI
- 10.1038/360040a0 · DOI · Paper page
- 10.1016/0003-2697(92)90317-Z · DOI
- 10.1016/0092-8674(92)90084-P · DOI
- 10.1038/258598a0 · DOI · Paper page
- Struhl K., 1987, Current Protocols in Molecular Biology, 3.16.1
- 10.1016/B978-0-12-442704-4.50014-1 · doi:10.1016/b978-0-12-442704-4.50014-1
- 10.1016/0076-6879(90)85008-C · DOI · Paper page
- 10.1016/S0021-9258(18)54106-5 · DOI · Paper page
- 10.1002/0471140864.ps0605s00 · DOI
- 10.1016/0003-2697(89)90184-X · doi:10.1016/0003-2697(89)90184-x
Cited by
ALARM NMR for HTS Triage and Chemical Probe Validation
Dahlin, J. L., Cuellar, M., Singh, G., Nelson, K. M., Strasser, J. M., Rappe, T., Xia, Y., Veglia, G., & Walters, M. A. (2018) · Current Protocols in Chemical Biology · doi:10.1002/cpch.35 · Cited by 25
Metadata
- Authors
- Petty, K. J.
- Affiliations
- Merck & Company West Point Pennsylvania
- Venue
- Current Protocols in Neuroscience
- Publisher
- Wiley
- Published
- 1998-11
- Volume
- 5
- Issue
- 1
- ISSN
- 1934-8584
- 1934-8576
- Cited by
- 0
- References
- 0
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Metal‐Chelate Affinity Chromatography. https://app.cochat.ai/papers/10.1002/0471142301.ns0510s05
- The paper
- Petty, K. J. (1998). Metal‐Chelate Affinity Chromatography. Current Protocols in Neuroscience. https://doi.org/10.1002/0471142301.ns0510s05
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.