Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 230

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Surgery versus medical therapy for heavy menstrual bleeding

Open access
Marjoribanks, Jane, Lethaby, Anne, Farquhar, Cindy · 2016 · Cochrane Database of Systematic Reviews

Abstract

BACKGROUND: Heavy menstrual bleeding significantly impairs the quality of life of many otherwise healthy women. Perception of heavy menstrual bleeding is subjective and management usually depends upon what symptoms are acceptable to the individual. Surgical options include conservative surgery (uterine resection or ablation) and hysterectomy. Medical treatment options include oral medication and a hormone-releasing intrauterine device (LNG-IUS). OBJECTIVES: To compare the effectiveness, safety and acceptability of surgery versus medical therapy for heavy menstrual bleeding. SEARCH METHODS: We searched the following databases from inception to January 2016: Cochrane Gynaecology and Fertility Group Trials Register, the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, EMBASE, PsycINFO and clinical trials registers (clinical trials.gov and ICTRP). We also searched the reference lists of retrieved articles. SELECTION CRITERIA: Randomised controlled trials (RCTs) comparing conservative surgery or hysterectomy versus medical therapy (oral or intrauterine) for heavy menstrual bleeding. DATA COLLECTION AND ANALYSIS: Two review authors independently selected the studies, assessed their risk of bias and extracted the data. Our primary outcomes were menstrual bleeding, satisfaction rate and adverse events. Where appropriate we pooled the data to calculate pooled risk ratios (RRs) or mean differences, with 95% confidence intervals (CIs), using a fixed-effect model. We assessed heterogeneity with the I(2) statistic and evaluated the quality of the evidence using GRADE methods. MAIN RESULTS: We included 15 parallel-group RCTs (1289 women). Surgical interventions included hysterectomy and endometrial resection or ablation. Medical interventions included oral medication and the levonorgestrel-releasing intrauterine device (LNG-IUS). The overall quality of the evidence for different comparisons ranged from very low to moderate. The main limitations were lack of blinding, attrition and imprecision. Moreover, it was difficult to interpret long-term study findings as many women randomised to medical interventions subsequently underwent surgery. Surgery versus oral medicationSurgery (endometrial resection) was more effective in controlling bleeding at four months (RR 2.66, 95% CI 1.94 to 3.64, one RCT, 186 women, moderate quality evidence) and also at two years (RR 1.29, 95% CI 1.06 to 1.57, one RCT, 173 women, low quality evidence). There was no evidence of a difference between the groups at five years (RR 1.14, 95% CI 0.97 to 1.34, one RCT, 140 women, very low quality evidence).Satisfaction with treatment was higher in the surgical group at two years (RR 1.40, 95% CI 1.13 to 1.74, one RCT, 173 women, moderate quality evidence), but there was no evidence of a difference between the groups at five years (RR 1.13, 95% CI 0.94 to 1.37, one RCT, 114 women, very low quality evidence). There were fewer adverse events in the surgical group at four months (RR 0.26, 95 CI 0.15 to 0.46, one RCT, 186 women). These findings require cautious interpretation, as 59% of women randomised to the oral medication group had had surgery within two years and 77% within five years. Surgery versus LNG-IUSWhen hysterectomy was compared with LNG-IUS, the hysterectomy group were more likely to have objective control of bleeding at one year (RR 1.11, 95% CI 1.05 to 1.19, one RCT, 223 women, moderate quality evidence). There was no evidence of a difference in quality of life between the groups at five or 10 years, but by 10 years 46% of women originally assigned to LNG-IUS had undergone hysterectomy. Adverse effects associated with hysterectomy included surgical complications such as bladder or bowel perforation and vesicovaginal fistula. Adverse effects associated with LNG-IUS were ongoing bleeding and hormonal symptoms.When conservative surgery was compared with LNG-IUS, at one year the surgical group were more likely to have subjective control of bleeding (RR 1.19, 95% CI 1.07 to 1.32, five RCTs, 281 women, low quality evidence, I(2) = 15%). Satisfaction rates were higher in the surgical group at one year (RR 1.16, 95% CI 1.04, to 1.28, six RCTs, 442 women, I(2) = 27%), but this finding was sensitive to the choice of statistical model and use of a random-effects model showed no conclusive evidence of a difference between the groups. There was no evidence of a difference between the groups in satisfaction rates at two years (RR 0.93, 95% CI 0.81 to 1.08, two RCTs, 117 women, I(2) = 1%).At one year there were fewer adverse events (such as bleeding and spotting) in the surgical group (RR 0.36, 95% CI 0.15 to 0.82, three RCTs, moderate quality evidence). It was unclear what proportion of women assigned to LNG-IUS underwent surgery over long-term follow-up, as there were few data beyond one year. AUTHORS' CONCLUSIONS: Surgery, especially hysterectomy, reduces menstrual bleeding more than medical treatment at one year. There is no conclusive

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/14651858.cd003855.pub3

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 230

Metadata

Authors
Marjoribanks, J., Lethaby, A., & Farquhar, C.
Venue
Cochrane Database of Systematic Reviews
Publisher
Wiley
Published
2016-01-29
Volume
2016
Issue
1
Pages
CD003855-CD003855
ISSN
  • 1361-6137 (ISSN-L)
  • 1465-1858
OpenAlex
W2132061576
Cited by
230
References
1
FWCI
18.44
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.