CoChat

Oral appliances and functional orthopaedic appliances for obstructive sleep apnoea in children

Carvalho, Fernando R, Lentini-Oliveira, Débora A, Machado, Marco Antonio C, Saconato, Humberto, Prado, Lucila BF, Prado, Gilmar F · 2007 · Cochrane Database of Systematic Reviews
Cited by 45

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Apnoea is a breathing disorder marked by the absence of airflow at the nose or mouth. In children, risk factors include adenotonsillar hypertrophy, obesity, neuromuscular disorders and craniofacial anomalies. The most common treatment for obstructive sleep apnoea syndrome (OSAS) in childhood is adenotonsillectomy. This approach is limited by its surgical risks, mostly in children with comorbities and, in some patients, by recurrence that can be associated with craniofacial problems. Oral appliances and functional orthopaedic appliances have been used for patients who have OSAS and craniofacial anomalies because they change the mandible posture forwards and potentially enlarge the upper airway and increase the upper airspace, improving the respiratory function. OBJECTIVES: To assess the effectiveness of oral appliances or functional orthopaedic appliances for OSAS in children. SEARCH STRATEGY: A sensitive search was developed for the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2005, Issue 3); PubMed (January 1966 to September 2005); EMBASE (1980 to September 2005); Lilacs (1982 to September 2005); BBO-Bibliografia Brasileira de Odontologia (1986 to September 2005); and SciELO (1997 to September 2005). There was no restriction of language or source of information. SELECTION CRITERIA: All randomised or quasi-randomised controlled trials comparing all types of oral and functional orthopaedic appliances with placebo or no treatment, in children 15 years old or younger. PRIMARY OUTCOME: reduction of apnoea to less than one episode per hour. SECONDARY OUTCOMES: dental and skeletal relationship, sleep parameters improvement, cognitive and phonoaudiologic function, behavioural problems, drop outs and withdrawals, quality of life, side effects (tolerability), economic evaluation. DATA COLLECTION AND ANALYSIS: Data were independently extracted by two review authors. Authors were contacted for additional information. Risk ratios with 95% confidence intervals were calculated for all important dichotomous outcomes. MAIN RESULTS: The initial search identified 384 trials. One of them, reporting results from a total of 23 patients, was suitable for inclusion in the review. Data provided in the published report did not answer all the questions from this review, but some of them were, and the presented results favour treatment. AUTHORS' CONCLUSIONS: At present there is no sufficient evidence to state that oral appliances or functional orthopaedic appliances are effective in the treatment of OSAS in children. Oral appliances or functional orthopaedic appliances may be helpful in the treatment of children with craniofacial anomalies which are risk factors for apnoea.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/14651858.cd005520.pub2

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 45

Metadata

Authors
Carvalho, F. R., Lentini-Oliveira, D. A., Machado, M. A. C., Saconato, H., Prado, L. B., & Prado, G. F.
Venue
Cochrane Database of Systematic Reviews
Published
2007-04-18
Issue
2
Pages
CD005520-CD005520
ISSN
1361-6137 (ISSN-L)
OpenAlex
W4236373520
Cited by
45
References
10
Type
reference entry
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.