Clinically-indicated replacement versus routine replacement of peripheral venous catheters
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Centers for Disease Control Guidelines recommend replacement of peripheral intravenous (IV) catheters every 72 to 96 hours. Routine replacement is thought to reduce the risk of phlebitis and bacteraemia. Catheter insertion is an unpleasant experience for patients and replacement may be unnecessary if the catheter remains functional and there are no signs of inflammation. Costs associated with routine replacement may be considerable. OBJECTIVES: To assess the effects of removing peripheral IV catheters when clinically indicated compared with removing and re-siting the catheter routinely. SEARCH STRATEGY: The Cochrane Peripheral Vascular Diseases Group searched their Specialised Register (last searched October 2009) and the Cochrane Central Register of Controlled Trials (CENTRAL) (last searched Issue Issue 4, 2009). We also searched MEDLINE (last searched October 2009). SELECTION CRITERIA: Randomised controlled trials that compared routine removal of peripheral IV catheters with removal only when clinically indicated in hospitalised or community dwelling patients receiving continuous or intermittent infusions. DATA COLLECTION AND ANALYSIS: Three review authors independently assessed trial quality and extracted data. MAIN RESULTS: In five trials (3408 participants) there was a 44% reduction in suspected catheter-related bacteraemia in the clinically-indicated group (0.2 versus 0.4%) but this was not statistically significant (odds ratio (OR) 0.57; 95% confidence interval (CI) 0.17 to 1.94; P = 0.37). Phlebitis was assessed in six trials (3455 patients); there was a non-significant increase in phlebitis in the clinically-indicated group (9% versus 7.2%); the OR was 1.24 (95% CI 0.97 to 1.60; P = 0.09). We also measured phlebitis per 1000 device days using data from five trials, (8779 device days). No statistical differences in the incidence of phlebitis per 1,000 device days was found (clinically indicated 1.6 cases per 1,000 catheter days versus 1.5 cases per 1,000 catheter days in the routine-replacement group).The combined OR was 1.04 (95% CI 0.81 to 1.32; P = 0.77). Cost was measured in two trials (961 patients). Cannulation costs were significantly reduced in the clinically-indicated group (mean difference (MD) -6.21; 95% CI -9.32 to -3.11; P = < 0.000). AUTHORS' CONCLUSIONS: The review found no conclusive evidence of benefit in changing catheters every 72 to 96 hours. Consequently, health care organisations may consider changing to a policy whereby catheters are changed only if clinically indicated. This would provide significant cost savings and would also be welcomed by patients, who would be spared the unnecessary pain of routine re-sites in the absence of clinical indications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Selecting Studies and Collecting Data
Higgins, J. P., & Deeks, J. J. (2008) · Cochrane Handbook for Systematic Reviews of Interventions · doi:10.1002/9780470712184.ch7 · Cited by 467
Cited by
Guidelines for the Prevention of Intravascular Catheter-related Infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · Clinical Infectious Diseases · doi:10.1093/cid/cir257 · Cited by 4,699
Guidelines for the prevention of intravascular catheter-related infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · American Journal of Infection Control · doi:10.1016/j.ajic.2011.01.003 · Cited by 1,066
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · Clinical Infectious Diseases · doi:10.1093/cid/cir138 · Cited by 560
Accepted but Unacceptable: Peripheral IV Catheter Failure
Helm, R. E., Klausner, J. D., Klemperer, J. D., Flint, L. M., & Huang, E. (2015) · Journal of Infusion Nursing · doi:10.1097/nan.0000000000000100 · Cited by 445
Rickard, C. M., Webster, J., Wallis, M. C., Marsh, N., McGrail, M. R., French, V., Foster, L., Gallagher, P., Gowardman, J. R., Zhang, L., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(12)61082-4 · Cited by 428
Self-citationClinically-indicated replacement versus routine replacement of peripheral venous catheters
Webster, J., Osborne, S., Rickard, C. M., & New, K. (2013) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd007798.pub3 · Cited by 313
Self-citationShort Peripheral Intravenous Catheters and Infections
Hadaway, L. (2012) · Journal of Infusion Nursing · doi:10.1097/nan.0b013e31825af099 · Cited by 211
Lim, S., Gangoli, G., Adams, E., Hyde, R., Broder, M. S., Chang, E., Reddy, S. R., Tarbox, M. H., Bentley, T., Ovington, L., et al. (2019) · INQUIRY: The Journal of Health Care Organization, Provision, and Financing · doi:10.1177/0046958019875562 · Cited by 66
Metadata
- Authors
- Webster, J., Osborne, S., Rickard, C., & Hall, J.
- Venue
- Cochrane Database of Systematic Reviews
- Publisher
- John Wiley & Sons, Ltd
- Published
- 2010-03-17
- Issue
- 3
- Pages
- CD007798-CD007798
- ISSN
- 1361-6137 (ISSN-L)
- OpenAlex
- W2800338241
- Cited by
- 70
- References
- 1
- Type
- reference entry
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.