Low oxygen concentrations for embryo culture in assisted reproductive technologies
Open accessThe DOI matches its Crossref record.
Abstract
BACKGROUND: During in vitro fertilisation (IVF) procedures, human preimplantation embryos are cultured in the laboratory. While some laboratories culture in an atmospheric oxygen concentration (˜ 20%), others use a lower concentration (˜ 5%) as this is more comparable to the oxygen concentration observed in the oviduct and the uterus. Animal studies have shown that high oxygen concentration could have a negative impact on embryo quality via reactive oxygen species causing oxidative stress. In humans, it is currently unknown which oxygen concentration provides the best success rates of IVF procedures, eventually resulting in the hightest birth rate of healthy newborns. OBJECTIVES: To determine whether embryo culture at low oxygen concentrations improves treatment outcome (better embryo development and more pregnancies and live births) in IVF and intracytoplasmic sperm injection (ICSI) as compared to embryo culture at atmospheric oxygen concentrations. SEARCH METHODS: The Menstrual Disorders and Subfertility Group Trials Register, Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, EMBASE and PsycINFO electronic databases were searched (up to 4th November 2011) for randomised controlled trials on the effect of low oxygen concentrations for human embryo culture. Furthermore, reference lists of all obtained studies were checked and conference abstracts handsearched. SELECTION CRITERIA: Only truly randomised controlled trials comparing embryo culture at low oxygen concentrations (˜ 5%) with embryo culture at atmospheric oxygen concentrations (˜ 20%) were included in this systematic review and meta-analysis. DATA COLLECTION AND ANALYSIS: Two review authors selected the trials for inclusion according to the above criteria. After that two authors independently extracted the data for subsequent analysis, and one author functioned as a referee in case of ambiguities. The statistical analysis was performed in accordance with the guidelines developed by The Cochrane Collaboration. MAIN RESULTS: Seven studies with a total of 2422 participants were included in this systematic review. Meta-analysis could be performed with the data of four included studies, with a total of 1382 participants. The methodological quality of the included trials was relatively low. Evidence of a beneficial effect of culturing in low oxygen concentration was found for live birth rate (OR 1.39; 95% CI 1.11 to 1.76; P = 0.005; I(2) = 0%); this would mean that a typical clinic could improve a 30% live birth rate using atmospheric oxygen concentration to somewhere between 32% and 43% by using a low oxygen concentration. The results were very similar for ongoing and clinical pregnancy rates. There was no evidence that culturing embryos under low oxygen concentrations resulted in higher numbers of adverse events such as multiple pregnancies, miscarriages or congenital abnormalities. AUTHORS' CONCLUSIONS: The results of this systematic review and meta-analysis suggest that culturing embryos under conditions with low oxygen concentrations improves the success rates of IVF and ICSI, resulting in the birth of more healthy newborns.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Keeley, T. P., & Mann, G. E. (2019) · Physiological Reviews · doi:10.1152/physrev.00041.2017 · Cited by 329
Rubio, I., Galán, A., Larreategui, Z., Ayerdi, F., Bellver, J., Herrero, J., & Meseguer, M. (2014) · Fertility and Sterility · doi:10.1016/j.fertnstert.2014.07.738 · Cited by 314
Wale, P. L., & Gardner, D. K. (2016) · Human Reproduction Update · doi:10.1093/humupd/dmv034 · Cited by 307
Oviduct: roles in fertilization and early embryo development
Li, S., & Winuthayanon, W. (2017) · Journal of Endocrinology · doi:10.1530/joe-16-0302 · Cited by 289
Assisted reproductive technology: an overview of Cochrane Reviews
Farquhar, C., & Marjoribanks, J. (2018) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010537.pub5 · Cited by 152
Metadata
- Authors
- Bontekoe, S., Mantikou, E., van Wely, M., Seshadri, S., Repping, S., & Mastenbroek, S.
- Venue
- Cochrane Database of Systematic Reviews
- Publisher
- Wiley
- Published
- 2012-07-11
- Volume
- 2012
- Issue
- 7
- Pages
- CD008950-CD008950
- ISSN
- 1361-6137 (ISSN-L)
- 1465-1858
- OpenAlex
- W2400639969
- Cited by
- 156
- References
- 0
- FWCI
- 10.42
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Low oxygen concentrations for embryo culture in assisted reproductive technologies. https://app.cochat.ai/papers/10.1002/14651858.cd008950.pub2
- The paper
- Bontekoe, S., Mantikou, E., van Wely, M., Seshadri, S., Repping, S., & Mastenbroek, S. (2012). Low oxygen concentrations for embryo culture in assisted reproductive technologies. Cochrane Database of Systematic Reviews. https://doi.org/10.1002/14651858.cd008950.pub2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.