The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Active body surface warming systems for preventing complications caused by inadvertent perioperative hypothermia in adults
Open accessAbstract
BACKGROUND: Inadvertent perioperative hypothermia is a phenomenon that can occur as a result of the suppression of the central mechanisms of temperature regulation due to anaesthesia, and of prolonged exposure of large surfaces of skin to cold temperatures in operating rooms. Inadvertent perioperative hypothermia has been associated with clinical complications such as surgical site infection and wound-healing delay, increased bleeding or cardiovascular events. One of the most frequently used techniques to prevent inadvertent perioperative hypothermia is active body surface warming systems (ABSW), which generate heat mechanically (heating of air, water or gels) that is transferred to the patient via skin contact. OBJECTIVES: To assess the effectiveness of pre- or intraoperative active body surface warming systems (ABSW), or both, to prevent perioperative complications from unintended hypothermia during surgery in adults. SEARCH METHODS: We searched the Cochrane Central Register of Controlled Trials (CENTRAL; Issue 9, 2015); MEDLINE (PubMed) (1964 to October 2015), EMBASE (Ovid) (1980 to October 2015), and CINAHL (Ovid) (1982 to October 2015). SELECTION CRITERIA: We included randomized controlled trials (RCTs) that compared an ABSW system aimed at maintaining normothermia perioperatively against a control or against any other ABSW system. Eligible studies also had to include relevant clinical outcomes other than measuring temperature alone. DATA COLLECTION AND ANALYSIS: Several authors, by pairs, screened references and determined eligibility, extracted data, and assessed risks of bias. We resolved disagreements by discussion and consensus, with the collaboration of a third author. MAIN RESULTS: We included 67 trials with 5438 participants that comprised 79 comparisons. Forty-five RCTs compared ABSW versus control, whereas 18 compared two different types of ABSW, and 10 compared two different techniques to administer the same type of ABSW. Forced-air warming (FAW) was by far the most studied intervention.Trials varied widely regarding whether the interventions were applied alone or in combination with other active (based on a different mechanism of heat transfer) and/or passive methods of maintaining normothermia. The type of participants and surgical interventions, as well as anaesthesia management, co-interventions and the timing of outcome measurement, also varied widely. The risk of bias of included studies was largely unclear due to limitations in the reports. Most studies were open-label, due to the nature of the intervention and the fact that temperature was usually the principal outcome. Nevertheless, given that outcome measurement could have been conducted in a blinded manner, we rated the risk of detection and performance bias as high.The comparison of ABSW versus control showed a reduction in the rate of surgical site infection (risk ratio (RR) 0.36, 95% confidence interval (CI) 0.20 to 0.66; 3 RCTs, 589 participants, low-quality evidence). Only one study at low risk of bias observed a beneficial effect with forced-air warming on major cardiovascular complications (RR 0.22, 95% CI 0.05 to 1.00; 1 RCT with 12 events, 300 participants, low-quality evidence) in people at high cardiovascular risk. We found no beneficial effect for mortality. ABSW also reduced blood loss during surgery but the magnitude of this effect seems to be irrelevant (MD -46.17 mL, 95% CI -82.74 to -9.59; I² = 78%; 20 studies, 1372 participants). The same conclusion applies to total fluids infused during surgery (MD -144.49 mL, 95% CI -221.57 to -67.40; I² = 73%; 24 studies, 1491 participants). These effects did not translate into a significant reduction in the number of participants being transfused or the average amount of blood transfused. ABSW was associated with a reduction in shivering (RR 0.39, 95% CI 0.28 to 0.54; 29 studies, 1922 participants) and in thermal comfort (standardized mean difference (SMD) 0.76, 95% CI 0.29 to 1.24; I² = 77%, 4 trials, 364 participants).For the comparison between different types of ABSW system or modes of administration of a particular type of ABSW, we found no evidence for the superiority of any system in terms of clinical outcomes, except for extending systemic warming to the preoperative period in participants undergoing major abdominal surgery (one study at low risk of bias).There were limited data on adverse effects (the most relevant being thermal burns). While some trials included a narrative report mentioning that no adverse effects were observed, the majority made no reference to it. Nothing so far suggests that ABSW involves a significant risk to patients. AUTHORS' CONCLUSIONS: Forced-air warming seems to have a beneficial effect in terms of a lower rate of surgical site infection and complications, at least in those undergoing abdominal surgery, compared to not applying any active warming system. It also has a beneficial effect on major cardiovascular complications in people with s
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantifying heterogeneity in a meta‐analysis
Higgins, J. P. T., & Thompson, S. G. (2002) · Statistics in Medicine · doi:10.1002/sim.1186 · Cited by 36,763
GRADE: an emerging consensus on rating quality of evidence and strength of recommendations
Guyatt, G. H., Oxman, A. D., Vist, G. E., Kunz, R., Falck-Ytter, Y., Alonso-Coello, P., & Schünemann, H. J. (2008) · BMJ · doi:10.1136/bmj.39489.470347.ad · Cited by 23,305
Self-citationCONSORT 2010 Statement: updated guidelines for reporting parallel group randomised trials
the CONSORT Group, Schulz, K. F., Altman, D. G., & Moher, D. (2010) · BMC Medicine · doi:10.1186/1741-7015-8-18 · Cited by 13,371
Hoffmann, T. C., Glasziou, P. P., Boutron, I., Milne, R., Perera, R., Moher, D., Altman, D. G., Barbour, V., Macdonald, H., Johnston, M., et al. (2014) · BMJ · doi:10.1136/bmj.g1687 · Cited by 10,548
Kurz, A., Sessler, D. I., & Lenhardt, R. (1996) · New England Journal of Medicine · doi:10.1056/nejm199605093341901 · Cited by 2,760
Frank, S. M. (1997) · JAMA · doi:10.1001/jama.1997.03540380041029 · Cited by 1,261
Mild hypothermia increases blood loss and transfusion requirements during total hip arthroplasty
Schmied, H., Reiter, A., Kurz, A., Sessler, D. I., & Kozek, S. (1996) · The Lancet · doi:10.1016/s0140-6736(96)90466-3 · Cited by 940
The Effects of Mild Perioperative Hypothermia on Blood Loss and Transfusion Requirement
Rajagopalan, S., Mascha, E., Na, J., & Sessler, D. I. (2008) · Anesthesiology · doi:10.1097/01.anes.0000296719.73450.52 · Cited by 905
Melling, A. C., Ali, B., Scott, E. M., & Leaper, D. J. (2001) · The Lancet · doi:10.1016/s0140-6736(01)06071-8 · Cited by 714
Complications and Treatment of Mild Hypothermia
Sessler, D. I. (2001) · Anesthesiology · doi:10.1097/00000542-200108000-00040 · Cited by 640
Mild Intraoperative Hypothermia Prolongs Postanesthetic Recovery
Lenhardt, R., Marker, E., Goll, V., Tschernich, H., Kurz, A., Sessler, D. I., Narzt, E., & Lackner, F. (1997) · Anesthesiology · doi:10.1097/00000542-199712000-00009 · Cited by 560
Frank, S. M., Higgins, M. S., Breslow, M. J., Fleisher, L. A., Gorman, R. B., Sitzmann, J. V., Raff, H., & Beattle, C. (1995) · Anesthesiology · doi:10.1097/00000542-199501000-00012 · Cited by 416
Mild Hypothermia Alters Propofol Pharmacokinetics and Increases the Duration of Action of Atracurium
Leslie, K., Sessler, D. I., Bjorksten, A. R., & Moayeri, A. (1995) · Anesthesia & Analgesia · doi:10.1097/00000539-199505000-00027 · Cited by 376
Aggressive Warming Reduces Blood Loss During Hip Arthroplasty
Winkler, M., Akça, O., Birkenberg, B., Hetz, H., Scheck, T., Arkiliç, C. F., Kabon, B., Marker, E., Grübl, A., Czepan, R., et al. (2000) · Anesthesia & Analgesia · doi:10.1097/00000539-200010000-00039 · Cited by 260
Physiologic Responses to Mild Perianesthetic Hypothermia in Humans
Sessler, D. I., Rubinstein, E. H., & Moayeri, A. (1991) · Anesthesiology · doi:10.1097/00000542-199110000-00009 · Cited by 248
Forced-Air Warming Maintains Intraoperative Normotherrnia Better Than Circulating-Water Mattresses
Kurz, A., Kurz, M., Poeschl, G., Faryniak, B., Redl, G., & Hackl, W. (1993) · Anesthesia & Analgesia · doi:10.1213/00000539-199307000-00018 · Cited by 234
Warming of intravenous and irrigation fluids for preventing inadvertent perioperative hypothermia
Campbell, G., Alderson, P., Smith, A. F., & Warttig, S. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd009891.pub2 · Cited by 177
Active Warming During Cesarean Delivery
Horn, E.-P., Schroeder, F., Gottschalk, A., Sessler, D. I., Hiltmeyer, N., Standl, T., & Schulte Esch, J. (2002) · Anesthesia & Analgesia · doi:10.1097/00000539-200202000-00034 · Cited by 165
Impact of Hypothermia on the Response to Neuromuscular Blocking Drugs
Heier, T., Caldwell, J. E., & Warltier, D. C. (2006) · Anesthesiology · doi:10.1097/00000542-200605000-00025 · Cited by 147
Survey on intraoperative temperature management in Europe
Torossian, A. (2007) · European Journal of Anaesthesiology · doi:10.1017/s0265021507000191 · Cited by 133
Effects of preinduction and intraoperative warming during major laparotomy
Böck, M., Müller, J., Bach, A., Bohrer, H., Martin, E., & Motsch, J. (1998) · British Journal of Anaesthesia · doi:10.1093/bja/80.2.159 · Cited by 120
Butwick, A. J., Lipman, S. S., & Carvalho, B. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000286167.96410.27 · Cited by 118
Effects of Comfort Warming on Preoperative Patients
Wagner, D., Byrne, M., & Kolcaba, K. Y. (2006) · AORN Journal · doi:10.1016/s0001-2092(06)63920-3 · Cited by 115
The Thermoregulatory Threshold in Humans during Nitrous Oxide-Fentanyl Anesthesia
Sessler, D. I., Olofsson, C. I., & Rubinstein, E. H. (1988) · Anesthesiology · doi:10.1097/00000542-198809000-00012 · Cited by 113
Farley, D. R. (2004) · Archives of Surgery · doi:10.1001/archsurg.139.7.739 · Cited by 91
Pu, Y., Cen, G., Sun, J., Gong, J., Zhang, Y., Zhang, M., Wu, X., Zhang, J., Qiu, Z., & Fang, F. (2013) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2013.05.013 · Cited by 90
Hofer, C. K., Worn, M., Tavakoli, R., Sander, L., Maloigne, M., Klaghofer, R., & Zollinger, A. (2005) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2004.07.002 · Cited by 82
Maternal and Newborn Outcomes Related to Maternal Warming During Cesarean Delivery
Fallis, W. M., Hamelin, K. J., Symonds, J., & Wang, X. (2006) · Journal of Obstetric, Gynecologic & Neonatal Nursing · doi:10.1111/j.1552-6909.2006.00052.x · Cited by 79
Effect of preoperative warming during cesarean section under spinal anesthesia
Chung, S. H., Lee, B.-S., Yang, H. J., Kweon, K. S., Kim, H.-H., Song, J., & Shin, D. W. (2012) · Korean Journal of Anesthesiology · doi:10.4097/kjae.2012.62.5.454 · Cited by 77
Mild hypothermia does not increase blood loss during total hip arthroplasty
Johansson, T., Lisander, B., & Ivarsson, I. (1999) · Acta Anaesthesiologica Scandinavica · doi:10.1034/j.1399-6576.1999.431006.x · Cited by 76
Effects of Warming Therapy on Pressure Ulcers—a Randomized Trial
Scott, E. M., Leaper, D. J., Clark, M., & Kelly, P. J. (2001) · AORN Journal · doi:10.1016/s0001-2092(06)61744-4 · Cited by 73
Infection control hazards associated with the use of forced-air warming in operating theatres
Wood, A. M., Moss, C., Keenan, A. C. M., Reed, M. R., & Leaper, D. J. (2014) · Journal of Hospital Infection · doi:10.1016/j.jhin.2014.07.010 · Cited by 64
Nesher, N., Zisman, E., Wolf, T., Sharony, R., Bolotin, G., David, M., Uretzky, G., & Pizov, R. (2003) · Anesthesia & Analgesia · doi:10.1097/00000539-200302000-00007 · Cited by 61
Thermal insulation for preventing inadvertent perioperative hypothermia
Alderson, P., Campbell, G., Smith, A. F., Warttig, S., Nicholson, A., & Lewis, S. R. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd009908.pub2 · Cited by 59
Alpha-2 adrenergic agonists for the prevention of shivering following general anaesthesia
Lewis, S. R., Nicholson, A., Smith, A. F., & Alderson, P. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011107.pub2 · Cited by 57
Grocott, H. P., Mathew, J. P., Carver, E. H., Phillips‐Bute, B., Landolfo, K. P., & Newman, M. F. (2004) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000096242.06561.c0 · Cited by 50
Intraoperative warming and post-operative cognitive dysfunction after total knee replacement
SALAZAR, F., Doñate, M., Boget, T., Bogdanovich, A., Basora, M., Torres, F., & Fàbregas, N. (2011) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2010.02362.x · Cited by 44
Paris, L. G., Seitz, M. A., McElroy, K. G., & Regan, M. B. (2014) · Journal of Obstetric, Gynecologic & Neonatal Nursing · doi:10.1111/1552-6909.12510 · Cited by 31
Perioperative hypothermia and postoperative opioid requirements
Persson, K., & Lundberg, J. (2001) · European Journal of Anaesthesiology · doi:10.1097/00003643-200110000-00007 · Cited by 27
O’Brien, D., Greenfield, M. L. V. H., Anderson, J. E., Smith, B. A., & Morris, M. (2010) · Journal of PeriAnesthesia Nursing · doi:10.1016/j.jopan.2010.01.008 · Cited by 24
Active warming systems for preventing inadvertent perioperative hypothermia in adults
Urrútia, G., Figuls, M. R. I., Campos, J. M., et al. (2011) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd009016 · Cited by 20
Self-citationTanaka, N., Ohno, Y., Hori, M., Utada, M., Ito, K., & Suzuki, T. (2013) · Journal of Perioperative Practice · doi:10.1177/175045891302300404 · Cited by 14
Evaluation of a new temperature management system during off-pump coronary artery bypass
Vassiliades, T. A. (2003) · Interactive Cardiovascular and Thoracic Surgery · doi:10.1016/s1569-9293(03)00112-9 · Cited by 12
Anaesthetists’ Knowledge of the QT Interval in a Teaching Hospital
Marshall, S. D., & Myles, P. S. (2005) · Anaesthesia and Intensive Care · doi:10.1177/0310057x0503300612 · Cited by 7
Cited by
Batchelor, T. J. P., Rasburn, N. J., Abdelnour-Berchtold, E., Brunelli, A., Cerfolio, R. J., Gonzalez, M., Ljungqvist, O., Petersen, R. H., Popescu, W. M., Slinger, P. D., et al. (2019) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezy301 · Cited by 1,366
Surgical Site Infection Prevention: A Review
Seidelman, J. L., Mantyh, C. R., & Anderson, D. J. (2023) · JAMA · doi:10.1001/jama.2022.24075 · Cited by 553
Debono, B., Wainwright, T. W., Wang, M. Y., Sigmundsson, F. G., Yang, M. M. H., Smid-Nanninga, H., Bonnal, A., Le Huec, J.-C., Fawcett, W. J., Ljungqvist, O., et al. (2021) · The Spine Journal · doi:10.1016/j.spinee.2021.01.001 · Cited by 444
Joliat, G., Kobayashi, K., Hasegawa, K., Thomson, J., Padbury, R., Scott, M., Brustia, R., Scatton, O., Tran Cao, H. S., Vauthey, J., et al. (2023) · World Journal of Surgery · doi:10.1007/s00268-022-06732-5 · Cited by 330
Metadata
- Authors
- Madrid, E., Urrútia, G., Roqué i Figuls, M., Pardo-Hernandez, H., Campos, J. M., Paniagua, P., Maestre, L., & Alonso-Coello, P.
- Venue
- Cochrane Database of Systematic Reviews
- Publisher
- Wiley
- Published
- 2016-04-21
- Volume
- 2016
- Issue
- 4
- Pages
- CD009016-CD009016
- ISSN
- 1361-6137 (ISSN-L)
- 1465-1858
- OpenAlex
- W2337947556
- Cited by
- 287
- References
- 44
- FWCI
- 20.24
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.