CoChat

Mini-Cog for the diagnosis of Alzheimer’s disease dementia and other dementias within a secondary care setting

Open access
Chan, Calvin CH, Fage, Bruce A, Burton, Jennifer K, Smailagic, Nadja, Gill, Sudeep S, Herrmann, Nathan, Nikolaou, Vasilis, Quinn, Terry J, Noel-Storr, Anna H, Seitz, Dallas P · 2019 · Cochrane Database of Systematic Reviews
Cited by 73

The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.

Abstract

BACKGROUND: The diagnosis of Alzheimer's disease dementia and other dementias relies on clinical assessment. There is a high prevalence of cognitive disorders, including undiagnosed dementia in secondary care settings. Short cognitive tests can be helpful in identifying those who require further specialist diagnostic assessment; however, there is a lack of consensus around the optimal tools to use in clinical practice. The Mini-Cog is a short cognitive test comprising three-item recall and a clock-drawing test that is used in secondary care settings. OBJECTIVES: The primary objective was to determine the diagnostic accuracy of the Mini-Cog for detecting Alzheimer's disease dementia and other dementias in a secondary care setting. The secondary objectives were to investigate the heterogeneity of test accuracy in the included studies and potential sources of heterogeneity. These potential sources of heterogeneity will include the baseline prevalence of dementia in study samples, thresholds used to determine positive test results, the type of dementia (Alzheimer's disease dementia or all causes of dementia), and aspects of study design related to study quality. SEARCH METHODS: We searched the following sources in September 2012, with an update to 12 March 2019: Cochrane Dementia Group Register of Diagnostic Test Accuracy Studies, MEDLINE (OvidSP), Embase (OvidSP), BIOSIS Previews (Web of Knowledge), Science Citation Index (ISI Web of Knowledge), PsycINFO (OvidSP), and LILACS (BIREME). We made no exclusions with regard to language of Mini-Cog administration or language of publication, using translation services where necessary. SELECTION CRITERIA: We included cross-sectional studies and excluded case-control designs, due to the risk of bias. We selected those studies that included the Mini-Cog as an index test to diagnose dementia where dementia diagnosis was confirmed with reference standard clinical assessment using standardised dementia diagnostic criteria. We only included studies in secondary care settings (including inpatient and outpatient hospital participants). DATA COLLECTION AND ANALYSIS: We screened all titles and abstracts generated by the electronic database searches. Two review authors independently checked full papers for eligibility and extracted data. We determined quality assessment (risk of bias and applicability) using the QUADAS-2 tool. We extracted data into two-by-two tables to allow calculation of accuracy metrics for individual studies, reporting the sensitivity, specificity, and 95% confidence intervals of these measures, summarising them graphically using forest plots. MAIN RESULTS: Three studies with a total of 2560 participants fulfilled the inclusion criteria, set in neuropsychology outpatient referrals, outpatients attending a general medicine clinic, and referrals to a memory clinic. Only n = 1415 (55.3%) of participants were included in the analysis to inform evaluation of Mini-Cog test accuracy, due to the selective use of available data by study authors. There were concerns related to high risk of bias with respect to patient selection, and unclear risk of bias and high concerns related to index test conduct and applicability. In all studies, the Mini-Cog was retrospectively derived from historic data sets. No studies included acute general hospital inpatients. The prevalence of dementia ranged from 32.2% to 87.3%. The sensitivities of the Mini-Cog in the individual studies were reported as 0.67 (95% confidence interval (CI) 0.63 to 0.71), 0.60 (95% CI 0.48 to 0.72), and 0.87 (95% CI 0.83 to 0.90). The specificity of the Mini-Cog for each individual study was 0.87 (95% CI 0.81 to 0.92), 0.65 (95% CI 0.57 to 0.73), and 1.00 (95% CI 0.94 to 1.00). We did not perform meta-analysis due to concerns related to risk of bias and heterogeneity. AUTHORS' CONCLUSIONS: This review identified only a limited number of diagnostic test accuracy studies using Mini-Cog in secondary care settings. Those identified were at high risk of bias related to patient selection and high concerns related to index test conduct and applicability. The evidence was indirect, as all studies evaluated Mini-Cog differently from the review question, where it was anticipated that studies would conduct Mini-Cog and independently but contemporaneously perform a reference standard assessment to diagnose dementia. The pattern of test accuracy varied across the three studies. Future research should evaluate Mini-Cog as a test in itself, rather than derived from other neuropsychological assessments. There is also a need for evaluation of the feasibility of the Mini-Cog for the diagnosis of dementia to help adequately determine its role in the clinical pathway.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/14651858.cd011414.pub2

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 29 references

Cited by

See all 73

Metadata

Authors
Chan, C. C., Fage, B. A., Burton, J. K., Smailagic, N., Gill, S. S., Herrmann, N., Nikolaou, V., Quinn, T. J., Noel-Storr, A. H., & Seitz, D. P.
Venue
Cochrane Database of Systematic Reviews
Publisher
Wiley
Published
2019-09-14
Volume
9
Pages
CD011414-CD011414
ISSN
  • 1361-6137 (ISSN-L)
  • 1465-1858
OpenAlex
W2098386490
Cited by
73
References
29
FWCI
8.26
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Mini-Cog for the diagnosis of Alzheimer’s disease dementia and other dementias within a secondary care setting. https://app.cochat.ai/papers/10.1002/14651858.cd011414.pub2
The paper
Chan, C. C., Fage, B. A., Burton, J. K., Smailagic, N., Gill, S. S., Herrmann, N., Nikolaou, V., Quinn, T. J., Noel-Storr, A. H., & Seitz, D. P. (2019). Mini-Cog for the diagnosis of Alzheimer’s disease dementia and other dementias within a secondary care setting. Cochrane Database of Systematic Reviews. https://doi.org/10.1002/14651858.cd011414.pub2

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.