The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Particle Image Velocimetry
Abstract
Particle Image Velocimetry (PIV) is a laser‐based technique to measure the instantaneous velocity distribution within a planar domain. The present chapter introduces the working principle of PIV and discusses its relevance for aerodynamic testing of aerospace vehicles and propulsion systems. The main components of an experiment performed by PIV are the seeding particles, the illumination system, the digital image recording and the algorithms used to analyze the motion of recorded particle images. The chapter closes with a discussion on the accuracy and spatial resolution of PIV measurements and on the data reduction procedures typically applied to post‐process PIV data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Particle-Imaging Techniques for Experimental Fluid Mechanics
Adrian, R. J. (1991) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fl.23.010191.001401 · Cited by 3,405
Digital particle image velocimetry
Willert, C. E., & Gharib, M. (1991) · Experiments in Fluids · doi:10.1007/bf00190388 · Cited by 1,991
Particle Image Velocimetry: A Practical Guide
Raffel, M., Willert, C. E., Wereley, S. T., & Kompenhans, J. (2007) · Springer eBooks · doi:10.1007/978-3-540-72308-0 · Cited by 1,634
Fundamentals of digital particle image velocimetry
Westerweel, J. (1997) · Measurement Science and Technology · doi:10.1088/0957-0233/8/12/002 · Cited by 1,425
Tomographic particle image velocimetry
Elsinga, G. E., Scarano, F., Wieneke, B., & van Oudheusden, B. W. (2006) · Experiments in Fluids · doi:10.1007/s00348-006-0212-z · Cited by 1,251
Self-citationUniversal outlier detection for PIV data
Westerweel, J., & Scarano, F. (2005) · Experiments in Fluids · doi:10.1007/s00348-005-0016-6 · Cited by 1,239
Self-citationStereoscopic particle image velocimetry
Prasad, A. K. (2000) · Experiments in Fluids · doi:10.1007/s003480000143 · Cited by 620
Motion of particles with inertia in a compressible free shear layer
Samimy, M., & Lele, S. K. (1991) · Physics of Fluids A: Fluid Dynamics · doi:10.1063/1.857921 · Cited by 504
Efficient detection of spurious vectors in particle image velocimetry data
Westerweel, J. (1994) · Experiments in Fluids · doi:10.1007/bf00206543 · Cited by 486
Westerweel, J., Dabiri, D., & Gharib, M. (1997) · Experiments in Fluids · doi:10.1007/s003480050082 · Cited by 476
Cited by
Interplay of cell dynamics and epithelial tension during morphogenesis of the Drosophila pupal wing
Etournay, R., Popović, M., Merkel, M., Nandi, A., Blasse, C., Aigouy, B., Brandl, H., Myers, G., Salbreux, G., Jülicher, F., et al. (2015) · eLife · doi:10.7554/elife.07090 · Cited by 373
Metadata
- Authors
- Scarano, F.
- Venue
- Encyclopedia of Aerospace Engineering
- Publisher
- Wiley
- Published
- 2010-12-15
- OpenAlex
- W3085975047
- Cited by
- 579
- References
- 12
- Type
- reference entry
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Particle Image Velocimetry. https://app.cochat.ai/papers/10.1002/9780470686652.eae074
- The paper
- Scarano, F. (2010). Particle Image Velocimetry. Encyclopedia of Aerospace Engineering. https://doi.org/10.1002/9780470686652.eae074
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.