The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Electric Properties of Tissues
Abstract
Passive electric properties of biological tissues such as permittivity and conductivity are important in applied problems of electrical stimulation in studying of human electromagnetic fields interactions and development of diagnostic and therapeutic procedures. The current densities and pathways resulting from an applied electrical stimulus are dictated to a large extent by the relative permittivity and specific conductivity of biological tissues; energy absorption also depends on tissue properties. We briefly present some theoretical basis for the current conduction in biologic materials and factors affecting the measurement of tissue dielectric properties that need to be taken into account when designing the measurement procedure. Large discrepancies between the data reported by different researchers are found in the literature, which are caused by factors such as different measuring techniques used, the fact that tissue samples were taken from different species, circumstances under which the measurements were performed, and many others. Electric properties of some biological tissues are summarized and data ranges of values found for relative permittivity and specific conductivity in the literature are given. Finally, we present some applications of bioimpedance measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/002 · Cited by 4,270
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/003 · Cited by 4,175
The dielectric properties of biological tissues: I. Literature survey
Gabriel, C., Gabriel, S., & Corthout, E. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/001 · Cited by 3,156
Geddes, L. A., & Baker, L. E. (1967) · Medical & Biological Engineering · doi:10.1007/bf02474537 · Cited by 1,610
Dielectric properties of tissues and biological materials: a critical review.
Foster, K. R., & Schwan, H. P. (1989) · PubMed · Cited by 1,186
CRC Handbook of Biological Effects of Electromagnetic Fields
Polk, C. (2019) · CRC Press eBooks · doi:10.1201/9781351071017 · Cited by 936
The measured electrical properties of normal and malignant human tissues from 50 to 900 MHz
Joines, W. T., Zhang, Y., Li, C., & Jirtle, R. L. (1994) · Medical Physics · doi:10.1118/1.597312 · Cited by 763
Dielectric properties of breast carcinoma and the surrounding tissues
Surowiec, A. J., Stuchly, S. S., Barr, J. R., & Swarup, A. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.1374 · Cited by 736
Dielectric and electronic properties of biological materials
Pethig, R. (1979) · Cited by 707
Handbook of biological effects of electromagnetic fields
(1996) · Choice Reviews Online · doi:10.5860/choice.33-6361 · Cited by 696
Cited by
Bioelectrical Impedance Methods for Noninvasive Health Monitoring: A Review
Bera, T. K. (2014) · Journal of Medical Engineering · doi:10.1155/2014/381251 · Cited by 407
A Survey on Intrabody Communications for Body Area Network Applications
Seyedi, M., Kibret, B., Lai, D. T. H., & Faulkner, M. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2254714 · Cited by 327
Review of Non-Invasive Glucose Sensing Techniques: Optical, Electrical and Breath Acetone
Shokrekhodaei, M., & Quinones, S. (2020) · Sensors · doi:10.3390/s20051251 · Cited by 221
Metadata
- Authors
- Miklavčič, D., Pavšelj, N., & Hart, F. X.
- Venue
- Wiley Encyclopedia of Biomedical Engineering
- Publisher
- Wiley
- Published
- 2006-04-14
- OpenAlex
- W2110180269
- Cited by
- 376
- References
- 37
- Type
- reference entry
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.