The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Magnetic Resonance Imaging: Physical Principles and Sequence Design
Abstract
Magnetic Resonance Imaging: A Preview. Classical of a Single Nucleus to a Magnetic Field. Rotating Reference Frames and Resonance. Magnetization, Relaxation and the Bloch Equation. The Quantum Mechanical Basis of Precession and Excitation. The Quantum Mechanical Basis of Thermal Equilibrium and Longitudinal Relaxation. Signal Detection Concepts. Introductory Signal Acquisition Methods: Free Induction Decay, Spin Echoes, Inversion Recovery and Spectroscopy. One-Dimensional Fourier Imaging, k-Space and Gradient Echoes. Multi-Dimensional Fourier Imaging and Slice Excitation. The Continuous and Discrete Fourier Transforms. Sampling and Aliasing in Image Reconstruction. Filtering and Resolution in Fourier Transform Image Reconstruction. Projection Reconstruction of Images. Signal, Contrast and Noise. A Closer Look at Radiofrequency Pulses. Water/Fat Separation Techniques. Fast Imaging in the Steady State. Segmented k-Space and Echo Planar Imaging. Magnetic Field Inhomogeneity Effects and T-2 Dephasing. Random Walks, Relaxation and Diffusion. Spin Density, T-1 and T-2 Quantification Methods in MR Imaging. Motion Artifacts and Flow Compensation. MR Angiography and Flow Quantification. Magnetic Properties of Tissues: Theory and Measurement. Sequence Design, Artifacts and Nomenclature. Introduction to MRI Coils and Magnets. Appendices. Index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“High-fidelity control of quantum spin systems is at the foundation of many applications such as quantum computing, coherent and optical spectroscopies, NMR, and MRI (1–5).”
From High-fidelity control of spin ensemble dynamics via artificial intelligence: from quantum computing to NMR spectroscopy and imaging (2022) · cites this paper as [4]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Nuclear Magnetic Resonance in One and Two Dimensions
Ernst, R. R., Bodenhausen, G., & Wokaun, A. (1990) · doi:10.1093/oso/9780198556473.001.0001 · Cited by 1,418
Cited by
Image reconstruction by domain-transform manifold learning
Zhu, B., Liu, J. Z., Cauley, S. F., Rosen, B. R., & Rosen, M. S. (2018) · Nature · doi:10.1038/nature25988 · Cited by 1,694
Magnetic resonance fingerprinting
Ma, D., Gulani, V., Seiberlich, N., Liu, K., Sunshine, J. L., Duerk, J. L., & Griswold, M. A. (2013) · Nature · doi:10.1038/nature11971 · Cited by 1,577
Susceptibility-Weighted Imaging: Technical Aspects and Clinical Applications, Part 1
Haacke, E. M., Mittal, S., Wu, Z., Neelavalli, J., & Cheng, Y.-C. N. (2009) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1400 · Cited by 1,113
Self-citationNanomaterials for In Vivo Imaging
Smith, B. R., & Gambhir, S. S. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00073 · Cited by 1,075
Imaging iron stores in the brain using magnetic resonance imaging
Haacke, E. M., Cheng, N. Y. C., House, M. J., Liu, Q., Neelavalli, J., Ogg, R. J., Khan, A., Ayaz, M., Kirsch, W., & Obenaus, A. (2005) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2004.10.001 · Cited by 995
Self-citation
Metadata
- Authors
- Brown, R. W., Cheng, Y. N., Haacke, E. M., Thompson, M. R., & Venkatesan, R.
- Publisher
- Wiley
- Published
- 2014-04-22
- OpenAlex
- W1854566075
- Cited by
- 2,688
- References
- 1
- FWCI
- 21.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.