CoChat

Compact Heat Exchangers

· 2022 · Thermal Design
Cited by 237

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Abstract

Double-pipe heat exchangers, shell-and-tube heat exchangers, and plate heat exchangers may have either parallel flow or counterflow arrangement. Finned-tube heat exchangers are gas-to-liquid heat exchangers and have dense fins attached on the tubes of the air side, because the heat transfer coefficient on the air side is generally one order of magnitude less than that on the liquidside. Plate-fin heat exchangers, are the most compact heat exchangers, commonly having triangular or rectangular cross sections. Printed-circuit heat exchangers were developed for corrosive and reactive chemical processes, which do not tolerate dissimilar materials in fabrication. Polymer compact heat exchangers also provide resistance to fouling. The louver-fin geometry provides heat transfer coefficients comparable to those of the offset-strip-fin geometry. In the last decades the importance of heat recovery in both civil and industrial applications is continuously growing. The chapter considers a typical plate finned heat pipe heat exchanger for recovering waste heat in a ventilation system.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/9781119686040.ch4

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 16 references

Cited by

See all 237

Metadata

Venue
Thermal Design
Publisher
Wiley
Published
2022-05-20
Pages
177-334
OpenAlex
W4281251543
Cited by
237
References
16
Type
other
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Compact Heat Exchangers. https://app.cochat.ai/papers/10.1002/9781119686040.ch4
The paper
Compact Heat Exchangers. (2022). Thermal Design. https://doi.org/10.1002/9781119686040.ch4

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.