The DOI matches its Crossref record.
Chemical Sensors and Biosensors for Medical and Biological Applications
Abstract
This book introduces the principles and concepts of chemical and biochemical sensors for analyzing medical as well as biological samples. For applications like analyzing or monitoring gastric juice or blood plasma, the potential of sensors is exceptionally large. Focussed on these applications, the interpretation of analytical results is explained. Specific advantages are compared to other analytical techniques. Numerous tables with data provide useful information not easily found elsewhere and make a handy source of reference. Ursula E. Spichiger-Keller is head of the Center for Chemical Sensors/Biosensors and Bioanalytical Chemistry at the Swiss Federal Institute of Technology (ETH) in Zurich.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Imani, S., Bandodkar, A. J., Mohan, A. M. V., Kumar, R., Yu, S., Wang, J., & Mercier, P. P. (2016) · Nature Communications · doi:10.1038/ncomms11650 · Cited by 861
Recent advances in biologically sensitive field-effect transistors (BioFETs)
Schöning, M. J., & Poghossian, A. (2002) · The Analyst · doi:10.1039/b204444g · Cited by 566
A review of the applications of Schiff bases as optical chemical sensors
Berhanu, A. L., Gaurav, Mohiuddin, I., Malik, A. K., Aulakh, J. S., Kumar, V., & Kim, K.-H. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.04.025 · Cited by 538
Biosensor technology: Technology push versus market pull
Luong, J. H. T., Male, K. B., & Glennon, J. D. (2008) · Biotechnology Advances · doi:10.1016/j.biotechadv.2008.05.007 · Cited by 454
Tuning the Selectivity of Two Chemosensors to Fe(III) and Cr(III)
Mao, J., Wang, L., Dou, W., Tang, X., Yan, Y., & Liu, W. (2007) · Organic Letters · doi:10.1021/ol7020687 · Cited by 380
Human tactile perception as a standard for artificial tactile sensing—a review
Dargahi, J., & Najarian, S. (2004) · The International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.3 · Cited by 369
Ratiometric Detection of Cr3+and Hg2+by a Naphthalimide-Rhodamine Based Fluorescent Probe
Mahato, P., Saha, S., Suresh, E., Di Liddo, R., Parnigotto, P. P., Conconi, M. T., Kesharwani, M. K., Ganguly, B., & Das, A. (2012) · Inorganic Chemistry · doi:10.1021/ic202073q · Cited by 319
Applications of electrospun nanofibers
Fang, J., Niu, H., Lin, T., & Wang, X. (2008) · Science Bulletin · doi:10.1007/s11434-008-0319-0 · Cited by 313
Aponte, V. M., Finch, D. S., & Klaus, D. M. (2006) · Life Sciences · doi:10.1016/j.lfs.2006.04.007 · Cited by 51
“Some of the problems that implantable selective electrodes have encountered in the past include lack of biocompatibility and the decay of sensor performance over time (Spichiger-Keller, 1998).”
Metadata
- Authors
- Spichiger‐Keller, U. E.
- Venue
- Wiley eBooks
- Publisher
- Wiley
- Published
- 1998-01-29
- OpenAlex
- W626271856
- Cited by
- 419
- References
- 0
- FWCI
- 4.00
- Type
- book
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.