The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Deformation Limits in Shape‐Memory Polymers
Abstract
This paper examines the link between polymer structure, temperature, and thermomechanics of shape-memory polymer networks. Strain to failure of the networks was extremely dependent on test temperature and reached a significant maximum near the onset of glass transition; a phenomenon denoted the deformability peak. A new protocol for maximizing stored strain in shape-memory polymers is presented and the results are discussed in regards to biomedical applications.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The recovery behavior is strongly influenced by the amount of stress applied to the polymer and by its thermal expansion behavior [101,186,187].”
From Review on the Functional Determinants and Durability of Shape Memory Polymers (2010) · cites this paper as [187]
In the citing paper
“The cyclic thermo-mechanical behavior of an SMP depends on the polymer's thermal and visco-elastic properties (e.g., the thermal transition temperatures, broadness of the transitions, expansion behavior, intensity of change in modulus), specimen size, clamping conditions (gauge length and clamping pressure), load cell sensitivity (setting of proportional-integral-derivative parameters) and testing”
From Review on the Functional Determinants and Durability of Shape Memory Polymers (2010) · cites this paper as [187]
Citations
Cites
Designing materials for biology and medicine
Langer, R., & Tirrell, D. A. (2004) · Nature · doi:10.1038/nature02388 · Cited by 3,198
Lendlein, A., & Kelch, S. (2002) · Kirk-Othmer Encyclopedia of Chemical Technology · doi:10.1002/0471238961.1908011612051404.a01 · Cited by 2,566
Biodegradable, Elastic Shape-Memory Polymers for Potential Biomedical Applications
Lendlein, A., & Langer, R. (2002) · Science · doi:10.1126/science.1066102 · Cited by 2,146
Light-induced shape-memory polymers
Lendlein, A., Jiang, H., Jünger, O., & Langer, R. (2005) · Nature · doi:10.1038/nature03496 · Cited by 2,006
Review of progress in shape-memory polymers
Liu, C., Qin, H., & Mather, P. T. (2007) · Journal of Materials Chemistry · doi:10.1039/b615954k · Cited by 1,942
Thermomechanics of shape memory polymers: Uniaxial experiments and constitutive modeling
Liu, Y., Gall, K., Dunn, M. L., Greenberg, A. R., & Diani, J. (2006) · International Journal of Plasticity · doi:10.1016/j.ijplas.2005.03.004 · Cited by 824
Self-citationBehl, M., & Lendlein, A. (2011) · Kirk-Othmer Encyclopedia of Chemical Technology · doi:10.1002/0471238961.1908011612051404.a01.pub2 · Cited by 663
Yakacki, C. M., Shandas, R., Lanning, C., Rech, B., Eckstein, A., & Gall, K. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.01.030 · Cited by 618
Self-citationShape Memory Materials for Biomedical Applications
El Feninat, F., Laroche, G., Fiset, M., & Mantovani, D. (2002) · Advanced Engineering Materials · doi:10.1002/1527-2648(200203)4:3<91::aid-adem91>3.0.co;2-b · Cited by 458
Shape memory polymer nanocomposites
Gall, K. (2002) · Acta Materialia · doi:10.1016/s1359-6454(02)00368-3 · Cited by 429
Self-citation
Research works printed but not linked: 1
- 10.1002/1521-3773(20020617)41:12<2034::AID-ANIE2034>3.0.CO;2-M · doi:10.1002/1521-3773(20020617)41:12<2034::aid-anie2034>3.0.co;2-m
Cited by
Shape-memory polymers and their composites: stimulus methods and applications
Leng, J., Lan, X., Liu, Y., & Du, S. (2011) · Progress in Materials Science · doi:10.1016/j.pmatsci.2011.03.001 · Cited by 1,495
Mather, P. T., Luo, X., & Rousseau, I. A. (2009) · Annual Review of Materials Research · doi:10.1146/annurev-matsci-082908-145419 · Cited by 911
Recent advances in polymer shape memory
Xie, T. (2011) · Polymer · doi:10.1016/j.polymer.2011.08.003 · Cited by 870
Shape-memory polymers as a technology platform for biomedical applications
Lendlein, A., Behl, M., Hiebl, B., & Wischke, C. (2010) · Expert Review of Medical Devices · doi:10.1586/erd.10.8 · Cited by 469
Huang, W. M., Zhao, Y., Wang, C. C., Ding, Z., Purnawali, H., Tang, C., & Zhang, J. L. (2012) · Journal of Polymer Research · doi:10.1007/s10965-012-9952-z · Cited by 299
Metadata
- Authors
- Yakacki, C. M., Willis, S., Luders, C., & Gall, K.
- Affiliations
- Georgia Institute of Technology (US)
- Venue
- Advanced Engineering Materials
- Publisher
- Wiley
- Published
- 2008-02
- Volume
- 10
- Issue
- 1-2
- Pages
- 112-119
- ISSN
- 1438-1656 (ISSN-L)
- 1527-2648
- OpenAlex
- W1981190495
- Cited by
- 121
- References
- 32
- Citations by year
- 2025: 3 · 2024: 4 · 2023: 3 · 2022: 4 · 2021: 4 · 2020: 8 · 2019: 6 · 2018: 8 · 2017: 9 · 2016: 14 · 2015: 9 · 2014: 7 · 2013: 10 · 2012: 7
- FWCI
- 17.02
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Advanced Engineering Materials (publishedVersion)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Advanced Materials and Mechanics
- Physical Sciences › Materials Science › Polymers and Plastics › Polymer composites and self-healing
- Physical Sciences › Materials Science › Biomaterials › Hydrogels: synthesis, properties, applications
- Keywords
- shape memory polymers, polymer networks, failure strain, glass transition, thermomechanics, polymer structure, temperature dependence, biomedical applications
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Deformation Limits in Shape‐Memory Polymers. https://app.cochat.ai/papers/10.1002/adem.200700184
- The paper
- Yakacki, C. M., Willis, S., Luders, C., & Gall, K. (2008). Deformation Limits in Shape‐Memory Polymers. Advanced Engineering Materials. https://doi.org/10.1002/adem.200700184
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.