Temperature‐Induced Hydrogels Through Self‐Assembly of Cholesterol‐Substituted Star PEG‐b‐PLLA Copolymers: An Injectable Scaffold for Tissue Engineering
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Partially cholesterol‐substituted 8‐arm poly(ethylene glycol)‐block‐poly(L‐lactide) (8‐arm PEG‐b‐PLLA‐cholesterol) has been prepared as a novel star‐shaped, biodegradable copolymer derivative. The amphiphilic 8‐arm PEG‐b‐PLLA‐cholesterol aqueous solution (polymer concentration, above 3 wt%) exhibits instantaneous temperature‐induced gelation at 34 °C, but the virgin 8‐arm PEG‐b‐PLLA does not, irrespective of concentration. Moreover, an extracellular matrix (ECM)‐like micrometer‐scale network structure has been created with favorable porosity for three‐dimensional proliferation of cells inside the hydrogel. This network structure is mainly attributed to specific self‐assembly between cholesterol groups. The 10 and 20 wt% hydrogels are eroded gradually in phosphate buffered saline at 37 °C over the course of a month, and after that the gel becomes completely dissociated. Moreover, L929 cells encapsulated into the hydrogel are viable and proliferate three‐dimensionally inside the hydrogels. Thus, in‐vitro cell culture studies demonstrate that 8‐arm PEG‐b‐PLLA‐cholesterol is a promising candidate as a novel injectable cellular scaffold.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hydrogels for tissue engineering: scaffold design variables and applications
Drury, J. L., & Mooney, D. J. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00340-5 · Cited by 5,136
Hydrogels for biomedical applications
Hoffman, A. S. (2002) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(01)00239-3 · Cited by 4,864
Thermosensitive sol-gel reversible hydrogels
Jeong, B., Kim, S. W., & Bae, Y. H. (2002) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(01)00242-3 · Cited by 1,478
Yamamoto, Y., Yasugi, K., Harada, A., Nagasaki, Y., & Kataoka, K. (2002) · Journal of Controlled Release · doi:10.1016/s0168-3659(02)00147-5 · Cited by 140
Cited by
Injectable and biodegradable hydrogels: gelation, biodegradation and biomedical applications
Li, Y., Rodrigues, J., & Tomás, H. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15203c · Cited by 1,445
Hydrogels for Protein Delivery
Vermonden, T., Censi, R., & Hennink, W. E. (2012) · Chemical Reviews · doi:10.1021/cr200157d · Cited by 1,091
Cellulose-based hydrogels: Present status and application prospects
Chang, C., & Zhang, L. (2011) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2010.12.023 · Cited by 1,081
Injectable Biodegradable Hydrogels
Nguyen, M. K., & Lee, D. S. (2010) · Macromolecular Bioscience · doi:10.1002/mabi.200900402 · Cited by 481
Li, C., Faulkner‐Jones, A., Dun, A. R., Jin, J., Chen, P., Xing, Y., Yang, Z., Li, Z., Shu, W., Liu, D., et al. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201411383 · Cited by 423
Metadata
- Authors
- Nagahama, K., Ouchi, T., & Ohya, Y.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2008-04-23
- Volume
- 18
- Issue
- 8
- Pages
- 1220-1231
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2154487475
- Cited by
- 156
- References
- 4
- FWCI
- 6.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.